Call us at 1-888-826-6342
Contains a dual element thermistor sensor with a series and a parallel resistor to linearize the thermistor output.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Additional Features | Temperature Accuracy | Features | Maximum Resistance | Application | Resistance or Output Type | Temperature Accuracy | Maximum Temperature Measurement | Minimum Temperature Measurement | Additional Features | Maximum Resistance |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
R1 = 18,700Ω, R2 = 35,250Ω
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
R1 = 18,700Ω, R2 = 35,250Ω
|
thermistor
|
R1 = 18,700Ω, R2 = 35,250Ω
|
±0.15°C, ±0.27°F
|
Not applicable
|
Not applicable
|
Linear Thermistor kit
|
R1 = 18,700Ω, R2 = 35,250Ω
|
|
Thermistor
|
R1 = 18,700Ω, R2 = 35,250Ω, R1 = 5700Ω, R1= 12,400Ω, R1 = 3200Ω, R2 = 6250Ω, R1 = 5700Ω, R2 = 12000Ω
|
±0.15°C, ±0.27°F
|
Thermistor Composite
|
±0.15°C, ±0.27°F
|
Thermistor Composite
|
R1 = 18,700Ω, R2 = 35,250Ω, R1 = 5700Ω, R1= 12,400Ω, R1 = 3200Ω, R2 = 6250Ω, R1 = 5700Ω, R2 = 12000Ω
|
thermistor
|
R1 = 18,700Ω, R2 = 35,250Ω, R1 = 5700Ω, R1= 12,400Ω, R1 = 3200Ω, R2 = 6250Ω, R1 = 5700Ω, R2 = 12000Ω
|
±0.15°C, ±0.27°F
|
Not applicable
|
Not applicable
|
Thermistor Composite
|
R1 = 18,700Ω, R2 = 35,250Ω, R1 = 5700Ω, R1= 12,400Ω, R1 = 3200Ω, R2 = 6250Ω, R1 = 5700Ω, R2 = 12000Ω
|
|
Thermistor
|
R1 = 3200Ω, R2 = 6250Ω
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
R1 = 3200Ω, R2 = 6250Ω
|
thermistor
|
R1 = 3200Ω, R2 = 6250Ω
|
±0.15°C, ±0.27°F
|
Not applicable
|
Not applicable
|
Linear Thermistor kit
|
R1 = 3200Ω, R2 = 6250Ω
|
|
Thermistor
|
R1 = 5700Ω, R2 = 12000Ω
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
R1 = 5700Ω, R2 = 12000Ω
|
thermistor
|
R1 = 5700Ω, R2 = 12000Ω
|
±0.15°C, ±0.27°F
|
Not applicable
|
Not applicable
|
Linear Thermistor kit
|
R1 = 5700Ω, R2 = 12000Ω
|
|
Thermistor
|
R1 = 5700Ω, R2 = 12,400Ω
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
±0.15°C, ±0.27°F
|
Linear Thermistor kit
|
R1 = 5700Ω, R2 = 12,400Ω
|
thermistor
|
R1 = 5700Ω, R2 = 12,400Ω
|
±0.15°C, ±0.27°F
|
Not applicable
|
Not applicable
|
Linear Thermistor kit
|
R1 = 5700Ω, R2 = 12,400Ω
|
Class B accuracy available in a variety of sizes. Single and Dual element versions.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Diameter | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|
|
RTD elements - Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
1.5 mm
|
8 mm
|
600°C (1110°F)
|
-200°C (-330°F)
|
|
RTD elements - Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
2 mm
|
4 mm L x 5 mm W
|
400°C (752°F)
|
-50°C (-58°F)
|
|
RTD elements - Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
2 mm
|
2 mm L x 2.4 mm W
|
400°C (752°F)
|
-50°C (-58°F)
|
|
RTD elements - Wire Wound
|
500 Ω
|
Class B per IEC751
|
2
|
2 mm
|
4 mm L x 5 mm W
|
400°C (752°F)
|
-50°C (-58°F)
|
|
RTD elements - Wire Wound
|
1000 Ω
|
Class B per IEC751
|
2
|
2 mm
|
4 mm L x 5 mm W
|
400°C (752°F)
|
-50°C (-58°F)
|
Sensor has a mounting hole to fit a #4 bolt, and comes standard with a 40" (1 meter) long cable and either 2, 3 or 4-wire connections.
Product Number | Application | Resistance or Output Type | Number of Wires | Mounting Style | Electrical Connection Type | Maximum Temperature Measurement | Minimum Temperature Measurement | Cable Length |
---|---|---|---|---|---|---|---|---|
|
Surface Mount RTD
|
100 Ω
|
Not Applicable
|
DIN Platinum
|
Stripped Leads
|
500°C (932°F)
|
-70°C (-94°F)
|
10 mm (0.39 in)
|
|
Surface Mount RTD
|
100 Ω
|
2
|
DIN Platinum
|
Stripped Leads
|
500°C (932°F)
|
-70°C (-94°F)
|
1 m (40 in)
|
|
Surface Mount RTD
|
100 Ω
|
3
|
DIN Platinum
|
Stripped Leads
|
500°C (932°F)
|
-70°C (-94°F)
|
1 m (40 in)
|
|
Surface Mount RTD
|
100 Ω
|
4
|
DIN Platinum
|
Stripped Leads
|
500°C (932°F)
|
-70°C (-94°F)
|
1 m (40 in)
|
Ready to use , no splicing or fragile elements to connect, use for embedment, insertion or as part of a larger assembly. Multiple configurations available.
Product Number | Category | Thermocouple Type | Process Temperature Range | Junction Type | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Wire Gauge | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
None
|
-50 to 200°C (-60 to 390°F)
|
None
|
100 Ω
|
Class A (temperature between -50 and 300 degree C),Class B
|
3
|
TFE
|
Stripped Leads
|
40 in
|
26 AWG
|
None
|
|
RTD
|
None
|
-200 to 350°C (-320 to 660°F)
|
None
|
1000 Ω
|
Class A (temperature between -50 and 300 degree C),Class B
|
3
|
Polyimide
|
Stripped Leads
|
40 in
|
26 AWG
|
None
|
|
RTD
|
None
|
-200 to 350°C (-320 to 660°F)
|
None
|
100 Ω
|
Class A (temperature between -50 and 300 degree C),Class B
|
3
|
Polyimide
|
Stripped Leads
|
40 in
|
26 AWG
|
None
|
|
RTD
|
None
|
-200 to 350°C (-320 to 660°F)
|
None
|
100 Ω
|
Class A (temperature between -50 and 300 degree C),Class B
|
3
|
Polyimide
|
Stripped Leads
|
40 in
|
26 AWG
|
None
|
|
RTD
|
None
|
-200 to 260°C (-320 to 500°F)
|
None
|
100 Ω
|
Class A (temperature between -50 and 300 degree C),Class B
|
3
|
TFE
|
Stripped Leads
|
40 in
|
26 AWG
|
None
|
Available in multiple resistances and in a variety of sizes. Elements are Class A accuracy and available individually.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Diameter | Probe Length | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement | Cable Length |
---|---|---|---|---|---|---|---|---|---|---|
|
RTD Elements - Thin Film
|
100 Ω
|
Class A per IEC60751
|
2
|
Not Applicable
|
2.3mm L x 2.1mm W x 0.9mm T
|
Not Applicable
|
500°C (932°F)
|
-70°C (-94°F)
|
10 mm
|
|
RTD Elements - Thin Film
|
100 Ω
|
+/- 0.1%
|
2
|
6.7 mm
|
2.1 mm
|
Washer
|
600°C (1112°F)
|
-50°C (-58°F)
|
15 mm
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class A per IEC60751
|
2
|
Not Applicable
|
9.5mm L x 1.9mm W x 0.9mm T
|
Not Applicable
|
500°C (932°F)
|
-50°C (-58°F)
|
10 mm
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class A per IEC60751
|
2
|
Not Applicable
|
3.9 mm L x 2.1mm W x 0.9mm T
|
Not Applicable
|
500°C (932°F)
|
-50°C (-58°F)
|
10 mm
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class A per IEC60751
|
2
|
Not Applicable
|
3.9mm L x 1.5mm W x 0.9mm T
|
Not Applicable
|
500°C (932°F)
|
-50°C (-58°F)
|
10 mm
|
Ready to use , no splicing or fragile elements to connect, use for embedment, insertion or as part of a larger assembly. Multiple configurations available.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Diameter | Probe Length | Maximum Temperature Measurement | Cable Length |
---|---|---|---|---|---|---|---|---|
|
Platinum RTD Capsules
|
100 Ω
|
±0.15+.002* t °C
|
3
|
0.125 in
|
0.6 in
|
510°C (950°F)
|
1 m (40 in)
|
|
Platinum RTD Capsules
|
1000 Ω
|
±0.15+.002* t °C
|
2
|
0.086 in
|
0.6 in
|
350°C (662°F)
|
1 m (40 in)
|
|
Platinum RTD Capsules
|
1000 Ω
|
±0.15+.002* t °C
|
3
|
0.125 in
|
0.6 in
|
510°C (950°F)
|
1 m (40 in)
|
|
Platinum RTD Capsules
|
1000 Ω
|
±0.15+.002* t °C
|
3
|
0.098 in
|
0.5 in
|
350°C (662°F)
|
1 m (40 in)
|
|
Platinum RTD Capsules
|
1000 Ω
|
±0.15+.002* t °C
|
3
|
0.098 in
|
0.5 in
|
260°C (500°F)
|
1 m (40 in)
|
Cylindrical encapsulation of the lead wires provides support when exposed to high vibration
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Diameter | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement | Cable Length |
---|---|---|---|---|---|---|---|---|---|
|
RTD Elements - Thin Film for High Vibration Applications
|
100 Ω
|
Class B per IEC751
|
2
|
2.8 mm (0.11 in)
|
8 mm (0.31 in)
|
500°C (932°F)
|
-70°C (-94°F)
|
6.0 mm (0.24 in)
|
|
RTD Elements - Thin Film for High Vibration Applications
|
100 Ω
|
Class B per IEC751
|
2
|
4.5 mm (0.18 in)
|
8 mm (0.31 in)
|
500°C (932°F)
|
-70°C (-94°F)
|
6.0 mm (0.24 in)
|
|
RTD Elements - Thin Film for High Vibration Applications
|
2 x 100 Ω
|
Class B per IEC751
|
2
|
2.8 mm (0.11 in)
|
8 mm (0.31 in)
|
500°C (932°F)
|
-70°C (-94°F)
|
6.0 mm (0.24 in)
|
|
RTD Elements - Thin Film for High Vibration Applications
|
2 x 100 Ω
|
Class B per IEC751
|
2
|
4.5 mm (0.18 in)
|
8 mm (0.31 in)
|
500°C (932°F)
|
-70°C (-94°F)
|
6.0 mm (0.24 in)
|
|
RTD Elements - Thin Film for High Vibration Applications
|
1000 Ω
|
Class B per IEC751
|
2
|
2.8 mm (0.11 in)
|
8 mm (0.31 in)
|
500°C (932°F)
|
-70°C (-94°F)
|
6.0 mm (0.24 in)
|
Solid state temp sensors convert a temp input into a proportional current output. Ideal for fast response surface measurements, controllers/meters, PC boards & custom probes.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Maximum Temperature Measurement | Minimum Temperature Measurement | Additional Features | Maximum Resistance |
---|---|---|---|---|---|---|---|
|
solid state sensor
|
current
|
±1.5°C
|
150°C (300°F)
|
-55°C (-67°F)
|
TO-52 Case
|
Not Applicable
|
|
solid state sensor
|
current
|
±1.5°C
|
150°C (300°F)
|
-55°C (-67°F)
|
Flat Pack Case
|
Not Applicable
|
|
solid state sensor
|
current
|
±0.8°C
|
150°C (300°F)
|
-55°C (-67°F)
|
Flat Pack Case
|
Not Applicable
|
|
solid state sensor
|
current
|
±0.8°C
|
150°C (300°F)
|
-55°C (-67°F)
|
TO-52 Case
|
Not Applicable
|
Constructed to be tolerant to thermal shock and suitable for low or high temperatures. Class B Accuracy
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Diameter | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|
|
RTD Elements - Glass Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
2.7 mm
|
13 mm (0.51 in)
|
400°C (752°F)
|
-220°C (-364°F)
|
|
RTD Elements - Glass Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
2.0 mm
|
10 mm
|
400°C (752°F)
|
-220°C (-364°F)
|
|
RTD Elements - Glass Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
4.5 mm (0.18 in)
|
15 mm
|
400°C (752°F)
|
-220°C (-364°F)
|
|
RTD Elements - Glass Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
2.0 mm
|
10 mm
|
450°C (842°F)
|
-220°C (-364°F)
|
|
RTD Elements - Glass Wire Wound
|
100 Ω
|
Class B per IEC751
|
2
|
1.8 mm
|
5 mm
|
450°C (842°F)
|
-220°C (-364°F)
|
Epoxy encapsulated thermistors with tinned copper leads. Various resistances and accuracies available.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Maximum Temperature Measurement | Minimum Temperature Measurement | Additional Features | Maximum Resistance |
---|---|---|---|---|---|---|---|
|
thermistor
|
10,000 Ω @ 25°C
|
±0.2°C @ 0 to 70°C
|
Not applicable
|
Not applicable
|
Not applicable
|
10,000 Ω @ 25°C
|
|
thermistor
|
2252 Ω @ 25°C
|
±0.2°C @ 0 to 70°C
|
Not applicable
|
Not applicable
|
Not applicable
|
2252 Ω @ 25°C
|
|
thermistor
|
3000 Ω @ 25°C
|
±0.2°C @ 0 to 70°C
|
Not applicable
|
Not applicable
|
Not applicable
|
3000 Ω @ 25°C
|
|
thermistor
|
5000 Ω @ 25°C
|
±0.2°C @ 0 to 70°C
|
Not applicable
|
Not applicable
|
Not applicable
|
5000 Ω @ 25°C
|
|
thermistor
|
30,000 Ω @ 25°C
|
±0.2°C @ 0 to 70°C
|
Not applicable
|
Not applicable
|
Not applicable
|
30,000 Ω @ 25°C
|
Output per the standard CY670 curve, used to measure temperatures between 30 and 500K (-243 to 227°C). Multiple accuracies available.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement | Maximum Resistance | Temperature Range | Band Type | Sensor Type |
---|---|---|---|---|---|---|---|---|---|---|
|
Beryllium oxide heat sink block
|
voltage
|
Not Applicable
|
Bolt on
|
226.85°C (440.33°F)
|
-271.8°C (-457.1°F)
|
Not Applicable
|
1.4 to 500 K
|
Band A
|
Beryllium oxide heat sink block
|
|
Cryogenic sensor
|
voltage
|
Not Applicable
|
Clamp style
|
226.85°C (440.33°F)
|
-271.8°C (-457.1°F)
|
Not Applicable
|
1.4 to 500 K
|
Band A
|
Cryogenic sensor
|
|
Cryogenic sensor
|
voltage
|
Not Applicable
|
Small copper bobbin
|
226.85°C (440.33°F)
|
-271.8°C (-457.1°F)
|
Not Applicable
|
1.4 to 500 K
|
Band A
|
Cryogenic sensor
|
|
Cryogenic sensor
|
voltage
|
Not Applicable
|
Large copper bobbin
|
226.85°C (440.33°F)
|
-271.8°C (-457.1°F)
|
Not Applicable
|
1.4 to 500 K
|
Band A
|
Cryogenic sensor
|
|
Cryogenic sensor
|
voltage
|
Not Applicable
|
Screw in
|
226.85°C (440.33°F)
|
-271.8°C (-457.1°F)
|
Not Applicable
|
1.4 to 500 K
|
Band A
|
Cryogenic sensor
|
Class B accuracy, -70 to 500°C temperature range, resistances include 100, 500 and 1000 Ohms at 0°C, various sizes available.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|
|
RTD Elements - Thin Film
|
100 Ω
|
Class B per IEC751
|
2
|
9.5 mm L x 1.9 mm W x 0.9 mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class B per IEC751
|
2
|
3.9 mm L x 2.1 mm W x 0.9 mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class B per IEC751
|
2
|
2.3 mm L x 2.1 mm W x 0.9 mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class B per IEC751
|
2
|
3.9 mm L x 1.5 mm W x 0.9 mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
|
RTD Elements - Thin Film
|
500 Ω
|
Class B per IEC751
|
2
|
3.9 mm L x 2.1 mm W x 0.9 mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
Class A, Class 1/3B and Class 1/10B accuracies available in various sizes
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Diameter | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|
|
RTD elements - Wire Wound
|
100 Ω
|
Class A per IEC60751
|
1
|
1.5 mm
|
15 mm
|
600°C (1110°F)
|
-200°C (-330°F)
|
|
RTD elements - Wire Wound
|
100 Ω
|
Class A per IEC60751
|
1
|
1.5 mm
|
25 mm
|
600°C (1110°F)
|
-200°C (-330°F)
|
|
RTD elements - Wire Wound
|
100 Ω
|
Class A per IEC60751
|
1
|
2.6 mm
|
30 mm
|
600°C (1110°F)
|
-200°C (-330°F)
|
|
RTD elements - Wire Wound
|
100 Ω
|
Class A per IEC60751
|
1
|
4.5 mm
|
30 mm
|
600°C (1110°F)
|
-200°C (-330°F)
|
|
RTD elements - Wire Wound
|
100 Ω
|
Class A per IEC60751
|
2
|
2.6 mm
|
30 mm
|
600°C (1110°F)
|
-200°C (-330°F)
|
Available in 100, 500 and 1000 ohm resistances and in a variety of sizes and accuracy classes. Purchase individually or in 100 count packs.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement | Cable Length | Additional Features |
---|---|---|---|---|---|---|---|---|---|
|
RTD Elements - Thin Film
|
1000 Ω
|
Class B per IEC60751
|
2
|
5 mm
|
500°C (932°F)
|
-50°C (-58°F)
|
10 mm
|
Standard
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class B per IEC60751
|
2
|
4.0mm L x 1.5mm W x 0.8mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
10 mm
|
Pack of 100
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class A per IEC60751
|
2
|
9.5mm L x 2.0mm W x 0.8mm T
|
300°C (572°F)
|
-30°C (-22°F)
|
10 mm
|
Pack of 100
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class B per IEC60751
|
2
|
9.5mm L x 2.0mm W x 0.8mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
10 mm
|
Pack of 100
|
|
RTD Elements - Thin Film
|
500 Ω
|
Class B per IEC60751
|
2
|
9.5mm L x 2.0mm W x 0.8mm T
|
500°C (932°F)
|
-50°C (-58°F)
|
10 mm
|
Pack of 100
|
Wide variety of resistances, accuracies and sizes available. Sold in packs of 100.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Number of Wires | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement | Cable Length |
---|---|---|---|---|---|---|---|---|
|
RTD Elements - Thin Film
|
100 Ω
|
Class A per IEC60751
|
2
|
4.0mm L x 1.5mm W x 0.9mm T
|
350°C (662°F)
|
-30°C (-22°F)
|
10 mm
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class A per IEC60751
|
2
|
2.2mm L x 2.2mm W x 0.9mm T
|
350°C (662°F)
|
-30°C (-22°F)
|
10 mm
|
|
RTD Elements - Thin Film
|
100 Ω
|
Class B per IEC60751
|
2
|
2.2mm L x 2.2mm W x 0.9mm T
|
500°C (932°F)
|
-70°C (-94°F)
|
10 mm
|
|
RTD Elements - Thin Film
|
1000 Ω
|
Class A per IEC60751
|
2
|
2.2mm L x 2.2mm W x 0.9mm T
|
350°C (662°F)
|
-30°C (-22°F)
|
10 mm
|
|
RTD Elements - Thin Film
|
1000 Ω
|
Class B per IEC60751
|
2
|
2.2mm L x 2.2mm W x 0.9mm T
|
500°C (932°F)
|
-70°C (-94°F)
|
10 mm
|
100 Ohm elements for use at temperatures between 14 to 873K (-259 to 600°C). Available in three sizes.
Product Number | Application | Resistance or Output Type | Temperature Accuracy | Probe Diameter | Probe Length | Maximum Temperature Measurement | Minimum Temperature Measurement | Maximum Resistance | Temperature Range | Sensor Type | Size | Style | Output Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
100 Ω
|
Not Applicable
|
1.8 mm
|
12.1 mm
|
600°C (1112°F)
|
-259.15°C (-434.47°F)
|
Not Applicable
|
14 to 873 K
|
Platinum RTD
|
2 x 20.3 mm
|
Tubular RTD Elements
|
100 OHMS
|