Appelez-nous au 1-888-826-6342
Thermocouples à coller Cement-On
Cement-On Surface T/C, Style 1-B, Type K, 40 in
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$177.17 |
10-24 | C$168.31 |
25-49 | C$164.77 |
50-99 | C$157.68 |
100-199 | C$154.14 |
200+ | C$150.59 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Temps de réponse de quelques millisecondes
- Constitués d'une plaquette 13 microns et d'un fil thermocouple de diamètre 0,25mm
- Très faible inertie thermique
- Types K, E, J et T
- Trois types de configuration adaptés aux mesures de surface
- Longueur des fils: 90cm pour les types 1 et 3, 15cm pour le type 2. Autres longueurs sur demande
CO1-K-B Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Thermocouple Type
Process Temperature Range
Cable Insulation
Cable Length
Features
Category
Sensor Application
Termination Connection Type
Color Code Standard
Mounting Style
Probe Diameter
Description
Les thermocouples à coller OMEGA sont caractérisés par un temps de réponse rapide. Ils existent en trois configurations conçues spécialement pour les mesures de température de surface. Les types 1 et 2 sont constitués d'une plaquette en alliage thermocouple 13 microns réalisée à partir d'un procédé spécial de fabrication dans lequel la jonction soudée du thermocouple a une épaisseur de 13 microns. Les types 1 et 2 sont plats et ont une inertie thermique très faible; ils sont parfaitement adaptés à la mesure de température de surfaces plates ou incurvées en métal, plastique ou céramique dans tous les cas où un temps de réponse rapide est nécessaire.Les types 1 et 2 sont fabriqués à partir de fils thermocouples de précision classe 1, de type K, E et T. Les types 1 et 2 ont le temps de réponse le plus rapide: type 1, 10 à 20 millisecondes , type 2:,2 à 5 milliesecondes.
Le type 3 est une version plus abordable réalisée à partir de fils thermocouple de diamètre de 0.25mm à jonction soudée électriquement et de précision classe 1. Leur temps de réponse est d'environ 300 millisecondes.
Pour obtenir la fiche des caractéristiques complètes, cliquez sur le lien en bas de page.
Rated 3 out of
5
by
none from
Good, but...
Does what they are supposed to.
COT-1
However the Small diameter wire is not the best for constant re-use.
Stripped wire length not good for the miniature connectors SMPW and HMPW.
if you want to use the little rubber grommet that comes with the connectors you will need to re-strip the bare ends.
And seeing as the price has gone up. The search is always on for an alternative.
Date published: 2015-12-17
Rated 5 out of
5
by
Leoman3 from
+Works great
really? Its a thermocouple, I like the stick on feature and it seems to work well.
Date published: 2016-11-07
Rated 5 out of
5
by
Ben Ha from
Great Product
Shipped fast and Packaged well! Would recommend for anyone needing a Cement-On Surface T/C, Style 1-B.
Date published: 2022-02-21
Rated 4 out of
5
by
jacklin from
review
good product good product good product good product
Date published: 2018-03-22
I would appreciate your advice for my project, I need a sensor with high accuracy to be installed on a pipe's surface and put it inside a soil container. the temperature range is going to be between 4 and -20 centigrade. Which product do you recommend?
Thank you for your inquiry. I would recommend the SA2C-K-72.
Date published: 2020-09-16
What is the recommended cement to adhere to surface with max temp of 550 F?
Thank you for your inquiry. We do not have any epoxy or cement for a maximum temperature of 550 F. The closest we can provide is the CC HIGH TEMP for a maximum temperature of 843 C. Here is the link: https://www.omega.com/en-us/accessories/adhesives-and-paste/ob-bond-chem-set/p/CC-HIGH-TEMP
Date published: 2023-09-01
WHAT GAUGE WIRE ARE THE LEADS? sOLID OR STRANDED.
Hi Mikechymbor
Leads are 30 awg solid
Best regards
OMEGA
Date published: 2020-06-29
What is the approximate size of the pad?
Thank you for your inquiry. Here are the pad dimensions: Style 1: 0.75 x 0.37", Style 1-B: 19 x 12.7 mm, Style 2: 1 x 0.72" and Style 3: 3/4 x 3/8". You can also find these dimensions in the manual here: https://assets.omega.com/manuals/Co-SERIES.pdf
Date published: 2023-03-28
We have an application where the surface temperature will reach about 1250 Deg C , The Duration of test 25 Sec to 130Sec. Please confirm whether we can use CO1-K-B or CO2-K or any other suitable
The CO1-K-B and the CO2-K are not suitable for use above 370C or 650C respectively. You should look at IR as a possible solution and contact the Temperature Engineers at temp@omega.com.
Date published: 2022-01-31
Cement on type CO2-K thermocouple with 6" leads,.... What is the best way to extend those leads to wire, then to connector..... do you have instruction on how to do this? Or do you sell a connector for this?....
Thank you for your inquiry. Using terminal blocks with extension wire and connectors would be the recommended option. Here is a link to our terminal block:
https://www.omega.com/en-us/temperature-measurement/temperature-connectors-panels-and-block-assemblies/terminal-blocks-and-lugs/ch-terminal-blocks/p/CH-49
Date published: 2024-03-28
Could you please give me some information about the foil material ? It is important for me to know thermal properties of foil. Many thanks in advance
There are several different materials used for the patches so send you request to temp@omega.com with the specific part number and it can be researched.
Date published: 2020-06-17
Can these thermocouples work with miniature mini t-type thermocouple connectors?
CO1-* come standard with stripped leads, however they'll work fine with a mini connector instead. Be sure to use same thermocouple calibration
Date published: 2022-11-11