Appelez-nous au 1-888-826-6342
Capteurs de surface RTD avec caoutchouc de silicone autocollant
Self-Adhesive Thermocouples
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$68.52 |
10-24 | C$65.09 |
25-99 | C$61.67 |
100-499 | C$58.24 |
500-999 | C$54.82 |
1000+ | C$51.39 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Polyimide Carrier
- Self-Adhesive Backing
- Low Mass Junction Area for Fast Response
- Resistant to many Chemicals and Oils
SA3-J-120-SRTC Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Thermocouple Type
Process Temperature Range
Termination Connection Type
Cable Length
Minimum Temperature Measurement
Category
Sensor Application
Cable Insulation
Color Code Standard
Probe Diameter
Features
These thermocouples can be used in outdoor and wet environments, including bright sunlight, with little to no effect on performance or accuracy. Our unique construction techniques provides a fast responding thermocouple junction in a thin and flexible mounting pad. These SA3 thermocouples are available in 2 styles, stripped #30AWG solid leads, or with a miniature color coded connector.
Specifications
Thermocouple: ANSI color code J/K/T/E or IEC color code JI/KI/TI/EI
Accuracy: Special limits of error
Junction Type: Ungrounded sensor construction
• Polyimide tape base with silicone adhesive and paper peel sheet
• Polyimide tape cover
• PFA insulated and jacketed 30 AWG cable
• Glass filled nylon connector when specified
Temperature Range:
Sensor: -17 to 260°C (0 to 500°F)
Connector: -29 to 180°C (-20 to 356°F)
Insulation Resistance: 100 M? minimum at 100 Vdc at room temperature and sensor mounted to surface
Specifications
Thermocouple: ANSI color code J/K/T/E or IEC color code JI/KI/TI/EI
Accuracy: Special limits of error
Junction Type: Ungrounded sensor construction
• Polyimide tape base with silicone adhesive and paper peel sheet
• Polyimide tape cover
• PFA insulated and jacketed 30 AWG cable
• Glass filled nylon connector when specified
Temperature Range:
Sensor: -17 to 260°C (0 to 500°F)
Connector: -29 to 180°C (-20 to 356°F)
Insulation Resistance: 100 M? minimum at 100 Vdc at room temperature and sensor mounted to surface
Rated 1 out of
5
by
User from
fragile, thin wire and insulation, not robust
Fragile, thin wire and insulation, not robust. One wire broke after first use.
Date published: 2020-05-21
Rated 1 out of
5
by
gewissler from
adhesive did not stick to stainless steel
poor adhesive. Did not stick to cleaned stainless steel surfaces. Had to apply anothe layer of fiberglass high heat tape to get them to stay in place.
Date published: 2020-12-02
Rated 5 out of
5
by
Anonymous from
Self-adhesive thermocouples
This tc serves its purpose well! Easy to install but you have to be very careful not to damage it.
Date published: 2020-09-05
Rated 1 out of
5
by
Unlikely future customer from
False advertisement - very disappointed
Even now you picture shows a thermocouple with a yellow connector at the end. I ordered the parts thinking that it was connectorized, but received the TCs with bare wire. Very disappointed in Omega.
Date published: 2020-08-24
Rated 5 out of
5
by
N8GR8 from
Great product
Worked great for the application. Well made and consistent.
Date published: 2024-02-23
Rated 5 out of
5
by
Anonymous from
Love This Product!
Works like a Charm! Need to attach these to a wax surface to go through an investment casting process and study how long the molds take to dry. These self adhesives work fantastic to stick to the mold and I would recommend.
Date published: 2023-06-04
Rated 4 out of
5
by
Anonymous from
Lab Test
Works good in lab test and connects to equipment well.
Date published: 2023-05-22
Rated 2 out of
5
by
Steve1 from
Super fragile - BE CAREFUL
Yes they're conveniently sized and when they work they work well. I ordered 3 (because I needed 3). One of them broke in the adhesive/PI sandwich section. The actual sensor wire broke off where the insulated wire began. This boggled my mind because that joint is contained within the adhesive section and is effectively strain relieved - that's how weak that joint is. Ordering some new thermocouples to try out.
Date published: 2023-01-04
In the product details, there is a column called "Minimum Temperature Measurement". The result is in inches.....specifically 36in for the device I ordered. What does that mean?
Thank You for your question.
That is a website error. The length in inches describes the length of the wire being used in for that part in accordance to that part number.
I will submit a ticket in order to have that category title fixed.
Date published: 2022-10-21
What is the accuracy of the SA3-K-SRTC? What is the response time of the SA3-K-SRTC?
Thank you for your inquiry. The accuracy of the SA3-K-SRTC is +/- 1.1°C or 0.4% of the reading, whichever is greater. For response time, please email temp@dwyeromega.com
Date published: 2024-07-29
are these well insulated electrically, what if these are pasted on high voltage copper bus bars with voltage up to 500V to 1000V are there any other products that for surface mount application that can be used on copper bsubar with 1000V on it.
Hi Amit,
The adhesive pad is electrically insulative but we do not provide a voltage rating. If applied to a surface with potential the leads should be considered to be at the same potential.
Best regards
OMEGA
Date published: 2020-11-13
What is the accuracy of the SA3-K-120 type thermocouple?
The accuracy of the SA3-K-120 is +/- 2.2 C
Date published: 2024-05-30
1. what is the accuracy of SA3-J-SRTC? 2. what is the response time of SA3-J-SRTC? 2 seconds or 0.3 seconds? Thank you
Surface Thermocouple achieves response times of less than 0.15 seconds.
Date published: 2020-03-17
I want to measure the metal tube surface temperature inside a tube in shell heat exchanger (undergraduate lab). The environment would be steam/water up to about 120 degrees C. Will the SA3 thermocouples function in this environment? Other suggestions?
Thank you for your inquiry Rolf. This probe works on wet environments that don't include the full water immersion and powerful water jets.
Date published: 2022-11-14
Can you get this item already attached to a connector for high temperatures?
This would need to be handled by contacting the Temperature Engineering group directly at temp@omega.com.
Date published: 2021-06-28
Are these thermocouples applicable in Vacuum environment (5torr- 10torr) pressure? at around 200 deg.
Thank you for your inquiry. These sensors are NOT vacuum rated.
Date published: 2021-06-10