Cart  |  Contact  |  Help  |  Francais  | 
1-888-826-6342  | 
Canada1-888-826-6342
International514-856-6928

Your Source for Process Measurement & Control

Variable Speed and Fixed Peristaltic Pumps

FPU2000, FPUVS2000, FPUDV2000

 | FPU2000, FPUVS2000, FPUDV2000

CAD1,355.00 FPUDVS2003

1 year warranty
  • Peristaltic Pump Tube Does Not Require Valves
  • Self Priming
  • High Outlet Pressure Capability of 100 psig on Most Models
  • Acceptable for Indoor Use
  • Corrosion Proof Valox Housing
  • Tamper Resistant Electronic Control Panel Cover
  • Tube Failure Detection
Pumps & Mixers - View related products

Description

The FPU2000 series has been discontinued. Please see the FPU2000A Series as a possible alternative or contact our Flow Engineering department.

The FPU2000 Series fixed pumps feed by an analog fixed 60 second timer. The pump can be on for 1 to 60 seconds. All FPU2000 Series have fixed speed outputs and can be adjusted by selecting the pumphead tube size and choosing the desired RPM (revolutions per minute).

The FPUVS2000 and FPUDVS2000 Series variable speed pumps are for continuous pumping relatively pulse free, even while adjusting the percentage of output. The variable speed pump requires the use of brushes on the DC motor. Excellent brush life expectancy (2000 hours). An extra set of brushes included with every pump.

The FPUDVS2000 Series will accept any one of three different types of external input signals; 4 to 20 mA, 0 to 10 Vdc, or frequency. The 4 to 20 mA and 0 to 10 Vdc loops must be powered. Two types of frequency inputs, AC sine waves (magnetic coils type outputs) and digital square waves (Hall Effect signals, contact closures), are acceptable. A jumper plug located on the circuit board is factory pre-set for AC sine wave signals, the jumper must be re-positioned when digital square wave signals are being used. All wiring connections are to be made inside of the junction box located on the side of the FPUDVS2000 Series.

A liquid tight connector is supplied and should be used for the external signal cable. The signal input wires are color coded to the type of signal being used.

SPECIFICATIONS
Maximum Working Pressure: 100 psig/6.9 bar (most models)
Maximum Fluid Temperature: 54°C (130°F)
Ambient Temperature Range: -10 to 43°C (14 to 110°F)
Enclosure: NEMA 3R (IP24) (acceptable for indoor use)
Pump Tube Material: Norprene
Duty Cycle: Continuous
Maximum Solids: 50% by volume
Maximum Viscosity: 5000 Centipoise
Maximum Suction Lift: Up to 9 m (30') water
Turn Down Ratio: 20:1
Power Requirements: 115 V 60 Hz 80 Watts, 220 V 50 Hz 40 Watts, 230 V 60 Hz 45 Watts
Variable Speed: 115 V 60 Hz 40 Watts, 220 V 50 Hz 40 Watts, 230 V 60 Hz 40 Watts
Dimensions: 155.6 H x 257.2 W x 228.6 mm D (618 x 1018 x 9")
Variable Speed: 159 H x 254 W x 235 mm D (6¼ x 10 x 9¼")
Weight: 3.6 kg (8 lb)
Tube Connection: Compression barb type (38" ID x ¼" OD)
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
Peristaltic Pumps
Fixed Timer Control
  
FPU2006 Star
CAD680.00
Availability: 1 week
 
Max Feed Rate: 42 ml/min (16 GPD)
  
FPU2010 Star
Consult Sales  
Availability: 
 
 
Max Feed Rate: 138 ml/min (52.5 GPD)
Variable Speed - Standard Percentage
  
FPUVS2002 Star
Consult Sales  
Availability: 
 
 
Max Feed Rate: 13 ml/min (4.9 GPD)
  
FPUVS2005 Star
CAD940.00
Availability: 1 week
 
Max Feed Rate: 28 ml/min (6.8 GPD)
Variable Speed - Digital Percentage Controllers
  
FPUDVS2005 Star
Consult Sales  
Availability: 
 
 
Max Feed Rate: 28 ml/min (6.8 GPD)
  
FPUDVS2007 Star
Consult Sales  
Availability: 
 
 
Max Feed Rate: 63 ml/min (24 GPD)
  
FPUDVS2008 Star
Consult Sales  
Availability: 
 
 
Max Feed Rate: 79 ml/min (30.1 GPD)
Accessories
  
FPU1000-AB Star
CAD37.50
Availability: 4 weeks
 
Quantity 2, armature bearings
  
FPU1000-IF Star
CAD47.50
Availability: 4 weeks
 
Injection fitting
  
FPU2000-14PTA Star
CAD36.50
Availability: 1 week
 
1/4" OD pump tube assembly
  
FPU2000-38PTA Star
CAD41.50
Availability: 1 week
 
3/8" OD pump tube assembly
  
FPU2000-716PTA Star
CAD42.50
Availability: 1 week
 
7/16" OD pump tube assembly
  
FPU2000-CW Star
CAD3.80
Availability: 1 week
 
Ceramic weight
  
FPU2000-PH Star
CAD80.00
Availability: 4 weeks
 
Pump head
Click to expand/minimize a list of what others bought with theFPU2000-PHB
FPU2000-PHB Star
CAD30.00
Availability: 4 weeks
 
Pump head cover with bearing
  
FPU2000-RA Star
CAD83.00
Availability: 1 week
 
Roller assemblies for 1/4 and 3/8" tube models
  
FPU2000-716RA Star
CAD83.00
Availability: 1 week
 
Roller assemblies for the 7/16" tube model
  
FPU2000-SP Star
CAD5.00
Availability: 1 week
 
Strainer plug
  
FPU2000-TN Star
CAD5.00
Availability: 1 week
 
Tube nut (3/8")
All dollar amounts on this site are shown in Canadian currency. Note: Comes complete with suction tube strainer, tube weight, suction tubing, discharge tubing and injection fitting with internal back-flow check valve, mounting hardware, and operator’s manual.

FPUVS and FPUDVS come with an additional set of brushes.

For optional CE approved 220 Vac/50Hz add suffix "-220/50" to model number, no additional charge.

For optional CE approved 230 Vac/60 Hz model add suffix "-230/60" to model number, no additional charge.

Note: 220 Vac/50Hz fixed speed models output approximately 20% less.


Ordering Example: (1) FPUDVS2007 Digital Peristaltic Pump, CAD1,355.00

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Variable Speed select from:
Nothing(leave field blank) for None
VS for Standard Percentage
DVS for Digital percentage controller

(2) Max Feed Rate select from:
01 for 6 ml/min (2.3 GPD)
02 for 13 ml/min (4.9 GPD)
03 for 21 ml/min (8 GPD)
04 for 25 ml/min (9.5 GPD)
05 for 18 ml/min (6.8 GPD)
06 for 42 ml/min (16 GPD)
07 for 63 ml/min (24 GPD)
08 for 79 ml/min (30.1 GPD)
09 for 57 ml/min (21.7 GPD)
10 for 138 ml/min (52.5 GPD)
11 for 200 ml/min (76.1 GPD)
12 for 250 ml/min (95.1 GPD)

(3) Additional Option select from:
Nothing(leave field blank) for None
-220/50 for 220 Vac/50Hz model
-230/60 for 230 Vac/60 Hz model
Note: All combinations may not be valid, check spec sheet for valid part numbers.