Ball Bearing Gas Turbine Flowmeters with Male NPT Fittings

FTB-930

Ball Bearing Gas Turbine Flowmeters with Male NPT Fittings | FTB-930

Ball Bearing Gas Turbine Flowmeters with Male NPT Fittings

CAD1,990.00 FTB-939

1 year warranty RoHS
  • ±1% of Reading Accuracy
  • Ball Bearing Design for Economy
  • 440C Bearing Retainers for Durability
  • Ball Bearings Field Replaceable Without Loss of Calibration
  • Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life
  • NIST Certificate Supplied Standard
Turbine, Paddle Wheel & Positive Displacement Flow Meters - View related products

Description

The OMEGA® FTB-930 & FTB-940 Series turbine meters have male NPT end fittings for easy connections. They are suitable for use with gases with a minimum density of 0.025 lb/ft 3 (air at STP is 0.0752 lb/ft 3 ).These units come supplied with a mating 2-wire connector and can be supplied with integrally mounted FLSC-60 Series signal conditioners to provide 4-20 mA, 0-5 V, or amplified pulse outputs. These turbine gas meters are intended for clean service only; where there is any doubt about the fluid, strainers are recommended.

OMEGA® precision turbine gas flowmeters are designed to measure actual cubic feet or actual volume passing through the meter. Before sizing a flowmeter, it is necessary to convert flow units (i.e., SCFM, LPM, etc.) to actual units. To convert to actual measured volume (ACFM) from standard volume (SCFM), use the following formula:
ACFM = SCFM x 14.7/Pa x Ta/530
where:
ACFM = Actual cubic feet per minute of measured gas flow
SCFM = Standard cubic feet per minute gas flow
Pa = Operating pressure (psia) in = (psig + 14.7)
Ta = Temperature in degrees, Rankine = (°F + 460)


SPECIFICATIONS
Accuracy: ±1.0% of reading
Repeatability: ±0.25%
Materials of Construction:
Body: 304/316 stainless steel
Rotor: 17-4 PH SS
Bearings: 440C stainless steel
Output: 30 mV p-p sinewave min.
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/Desc.
Availability
Price
Description
Qty
RoHS
  
FTB-931B
Star
Availability: 1 week  
CAD1,575.00   
0.35-3.5 Max Linear Range (AFCM); 1/2 End Connections MNPT (in)
RoHS compliancy undetermined
  
FTB-932
Star
Availability: 1 week  
CAD1,575.00   
.75-5 Max Linear Range (ACFM); 1/2 End Connections MNPT (in)
RoHS compliant
  
FTB-933
Star
Availability: 1 week  
CAD1,575.00   
1-10 Max Linear Range (ACFM); 1/2 End Connections MNPT (in)
RoHS compliant
  
FTB-934
Star
Availability:  
Consult Sales  
2-20 Max Linear Range (ACFM); 1/2 End Connections MNPT (in)
 
RoHS compliant
  
FTB-935
Star
Availability: 1 week  
CAD1,575.00   
2.5-28 Max Linear Range (ACFM); 3/4 End Connections MNPT (in)
RoHS compliant
Click to expand/minimize a list of what others bought with theFTB-936
FTB-936
Star
Availability: 8 weeks  
CAD1,590.00   
4-60 Max Linear Range (ACFM); 1 End Connections MNPT (in)
RoHS compliant
  
FTB-937
Star
Availability: 1 week  
CAD1,590.00   
6-100 Max Linear Range (ACFM); 1 1/4 End Connections MNPT (in)
RoHS compliant
  
FTB-938
Star
Availability: 8 weeks  
CAD1,795.00   
8-130 Max Linear Range (ACFM); 1 1/2 End Connections MNPT (in)
RoHS compliant
  
FTB-939
Star
Availability: 7 weeks  
CAD1,990.00   
15-250 Max Linear Range (ACFM); 2 End Connections MNPT (in)
RoHS compliant
  
FTB-940
Star
Availability:  
Consult Sales  
25-450 Max Linear Range (ACFM); 2 1/2 End Connections MNPT (in)
 
RoHS compliant
  
FTB-941
Star
Availability: 8 weeks  
CAD2,970.00   
40-650 Max Linear Range (ACFM); 3 End Connections MNPT (in)
RoHS compliant
  
FTB-942
Star
Availability: 8 weeks  
CAD3,650.00   
75-1200 Max Linear Range (ACFM); 4 End Connections MNPT (in)
RoHS compliancy undetermined
Signal Conditioners (Order as a System for factory Scaling on FLSC-61 and FLSC-62, For Example: SYS/FTB-931/FLSC-62)
  
FLSC-61
Star
Availability: 8 weeks  
CAD700.00   
0-5/0-10 Volt output
RoHS compliant
Click to expand/minimize a list of what others bought with theFLSC-62A
FLSC-62A
Star
Availability: In Stock  
CAD700.00   
4-20 mA output
RoHS compliant
  
FLSC-64
Star
Availability: In Stock  
CAD425.00   
Amplifier (Squarewave Output)
RoHS compliant
Accessories
Click to expand/minimize a list of what others bought with thePSR-24S
PSR-24S
Star
Availability: In Stock  
CAD81.00   
Regulated power supply, US plug, 90-264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL
Not RoHS compliant
All dollar amounts on this site are shown in Canadian currency. Note: Comes complete with operator’s manual and NIST Certificate for air.

To order turbine meters with integral signal conditioners, specify model as a system such as : SYS/FTB-932/FLSC-62A. Omega will scale the signal conditioner with the appropriate calibration information from the turbine meter specified.

No other calibrations are available.

Compatible Meters: DPF701, DPF402, DPF70 with FLSC-AMP, DPF10, DPF500, FC20, 21, 22

Contact Flow Engineering Dept


Ordering Example: (1) DPF701 1/8 DIN Panel Meter for Rate or Totalization, CAD350.00  plus (1) FTB-932 0.75-5 Max Linear Range (ACFM); 1/2 End Connections MNPT (in), CAD1,575.00, CAD350.00 + 1,575.00 = CAD1,925.00

Product Manuals:

Download FTB-900/FTB9500 Series - Precision Turbine Flowmeters
Download FLSC-64 - Pulse Amplifier
Download FLSC-62A - Signal Conditioner
Download FLSC-61 - 3-Wire Analog Transmitter