Cart  |  Contact  |  Help  |  Francais  | 
1-888-826-6342  | 
Canada1-888-826-6342
International514-856-6928

Your One-Stop Source for Process Measurement & Control!

Vapor and Gas Actuated Thermometers, Panel & Surface Mount

VA and GA Series

Vapor and Gas Actuated Thermometers | VA and GA Series

Vapor and Gas Actuated Thermometers

See All Models Below

RoHS
  • Accuracy ±1 Scale Division or 1% Scale for Gas
  • Brass Movement with Precision Gearing
  • White Dial with Black Graduations
  • Phosphor Bronze Bourdon Tube
Glass Bulb and DialTemp™ Thermometers - View related products

Description

OMEGA® remote vapor- and gas-actuated thermometers are manufactured to the highest standards for a wide range of uses and can be fitted into almost any temperatureindicating application. These instruments are ideal for remote reading, such as panel installations, with capillary lengths of 1 to 100'. Vapor, or more precisely vaporized liquid, thermometers will give excellent readings, provided the temperature being measured is above or below ambient temperature. Vapor instruments also have progressive graduations and are best read in the upper 2/3 of the dial range. Many ranges are available between -40 to 232°C (-40 to 450°F), and care should be taken to select a range that will locate the operating temperatures within the upper 2/3 of the dial range.

OMEGA gas-actuated thermometers combine advanced gas coil technology with a state-of-the-art gas absorbent (Class IV) thermal system, producing a superior temperature measurement instrument that can be fitted to a wide variety of applications. Gas-actuated thermometers have an advantage over vapor-actuated thermometers in that they are more accurate over the full range. They also operate at higher and lower ranges than vapor-actuated thermometers.

The linear dial on all OMEGA gas thermometers provides a consistent 1% accuracy across the full span of each range. This, combined with over 20 Fahrenheit and dual ranges, from -196 to 649°C (-320 to 1200°F), provides complete coverage of all normal temperature requirements.

SPECIFICATIONS
Dial Sizes: 2", 2½", 3½", 4½"
Dial: Aluminum with white finish and black markings
Pointer: Furnished standard adjustable
Movement: Brass with precision gearing
Bourdon Tube: Vapor-phosphor bronze
Gas: Nitrogen in nispan coil
Accuracy:
    Vapor: ±1 scale division
    Gas: ±1% of scale
Process Connection: Plain bulb, ½NPT union; or thermowell
Note: thermowells must be used whenever the bulb would be exposed to pressure, fluid velocity, or corrosive media.
Window: Polycarbonate STD; glass available on all models
Bulb: Stainless steel or copper; bulb O.D. 3/8" on plain bulbs, 7/16" with threads. Bulb lengths from 2½" to 7 7/8" depending on capillary length.
Capillary: Copper, copper with bronze braid armor; stainless steel with stainless steel armor; capillary lengths 1 to 100' (standard length, 5')
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
RoHS
Description
GA-45RR-FN-E-51-M2 Star
CAD640.00
Availability: 1 week
RoHS compliancy undetermined
Gas Actuated Thermometer
GA-35FR-FL-E-15-J3 Star
CAD690.00
Availability: 7 weeks
RoHS compliancy undetermined
Gas Actuated Thermometer
GA-25FR-FN-E-30-L2 Star
Consult Sales  
Availability: 
 
RoHS compliant
Gas Actuated Thermometer
GA-35RB-FL-E-05-J1 Star
CAD395.00
Availability: 1 week
RoHS compliant
Gas Actuated Thermometer
VA-20RR-60-C-3-J2 Star
CAD113.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-20UR-(72-A-05-K2) Star
CAD86.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-25FR-33-E-05-J3 Star
CAD188.00
Availability: 4 weeks
RoHS compliancy undetermined
Vapor Actuaterd Thermometer
VA-35UR-(73-E-06-J3) Star
CAD220.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RB-51-D-50-L2 Star
CAD540.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-25FR-56-E-05-J3 Star
CAD174.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-20UR-81-A-05-J1 Star
CAD73.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-25FR-70-C-05-J2 Star
CAD107.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RB-50-C-06-J1 Star
CAD151.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RB-51-D-25-L2 Star
CAD353.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RB-51-D-50-L2 Star
CAD540.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RB-60-D-3-M2 Star
Consult Sales  
Availability: 
 
RoHS compliant
Vapor Actuated Thermometer
VA-35RR-(20-A-05-J1) Star
CAD109.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RR-(30-D-05-J1) Star
CAD171.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RR-(49-A-05-J1) Star
CAD109.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-35RR-(60-E-05-J1) Star
CAD194.00
Availability: 7 weeks
RoHS compliant
Vaport Actuated Thermometer
VA-35RR-51-C-10-J2 Star
CAD159.00
Availability: 6 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-45FL-60-E-10-J3 Star
CAD400.00
Availability: 4 weeks
RoHS compliancy undetermined
Vapor Actuated Thermometer
VA-45RB-(50-E-10-L2) Star
CAD301.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-45FR-61-E-10-J3 Star
CAD327.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-45RB-71-C-15-J2 Star
CAD193.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-45RB-80-C-08-K2 Star
CAD178.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer
VA-45RR-20-E-5-J1 Star
CAD204.00
Availability: 1 week
RoHS compliant
Vapor Actuated Thermometer
VA-45RR-30-A-10-J1 Star
CAD133.00
Availability: 7 weeks
RoHS compliant
Vapor Actuated Thermometer

Order By Part Number

Part Number
Qty
Part Number
Qty


All dollar amounts on this site are shown in Canadian currency.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Style select from:
VA for Vapor Actuated Thermometer
GA for Gas Actuated Thermometer

(2) Case Style and Size select from:
20FR for Front Flange (Panel Mount) style.Dial 2 in. Case stainless steel. Connection location rear
25FR for Front Flange (Panel Mount) style. Dial 2 1/2 in. Case stainless steel. Connection location rear
35FR for Front Flange (Panel Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
45FR for Front Flange (Panel Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location rear
45FL for Front Flange (Panel Mount) style. Dial 4 1/2 in. Case black aluminum (hinge ring type). Connection location lower rear
20UR for U-Clamp (Panel Mount) style. Dial 2 in. Case stainless steel. Connection location rear
25UR for U-Clamp (Panel Mount) style. Dial 2 1/2 in. Case stainless steel. Connection location rear
35UR for U-Clamp (Panel Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
20RR for Rear flange (Surface Mount) style. Dial 2 in. Case stainless steel. Connection location rear
35RR for Rear flange (Surface Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location rear
35RB for Rear flange (Surface Mount) style. Dial 3 1/2 in. Case stainless steel. Connection location bottom
45RR for Rear flange (Surface Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location rear
45RB for Rear flange (Surface Mount) style. Dial 4 1/2 in. Case stainless steel. Connection location bottom
45TB for Rear flange (Surface Mount) style. Dial 4 1/2 in. Case Phenolic. Connection location bottom (turret)

(3) Temperature Range (ranges 300°F or above for vapor-actuate and all gas-actuated models only offered with stainless steel systems.) select from:
20 for -40 to 60°F (VA Range only)
21 for -40 to 60°F (-40 to 15°C) (VA Range only)
30 for -40 to 110°F (VA Range only)
31 for -40 to 110°F (-40 to 40°C) (VA Range only)
32 for -20 to 120°F (VA Range only)
33 for -20 to 120°F (-30 to 50°C) (VA Range only)
72 for 0 to 180°F (VA Range only)
73 for 0 to 180°F (-20 to 80°C) (VA Range only)
49 for 0 to 150°F (VA Range only)
79 for 0 to 150°F (-15 to 65°C) VA Range only)
80 for 20 to 220°F (VA Range only)
81 for 20 to 220°F (0 to 105°C) (VA Range only)
50 for 40 to 240°F (VA Range only)
51 for 40 to 240°F (0 to 115°C) (VA Range only)
56 for 0 to 250°F (VA Range only)
57 for 0 to 250°F (-20 to 120°C) (VA Range only)
60 for 30 to 300°F (VA Range only)
61 for 30 to 300°F (0 to 150°C) (VA Range only)
68 for 100 to 350°F (VA Range only)
66 for 100 to 350°F (40 to 175°C) (VA Range only)
FB for -320 to 100°F (GA Range only)
DB for -320 to 100°F (-200 to 40°C) (GA Range only)
FE for -120 to 120°F (GA Range only)
DE for -120 to 120°F (-85 to 50°C) (GA Range only)
FG for -40 to 180°F (GA Range only)
DG for -40 to 180°F (-40 to 80°C) (GA Range only)
FH for 0 to 120°F (GA Range only)
DH for 0 to 120°F (-15 to 50°C) (GA Range only)
FJ for 60 to 120°F (GA Range only)
DJ for 60 to 120°F (15 to 50°C) (GA Range only)
FL for 20 to 240°F (GA Range only)
DL for 20 to 240°F (-5 to 110°C) (GA Range only)
FN for 0 to 300°F (GA Range only)
DN for 0 to 300°F (-10 to 150°C) (GA Range only)
FP for 50 to 550°F (GA Range only)
DP for 50 to 550°F (10 to 29°C) (GA Range only)
FR for 50 to 750°F (GA Range only)
DR for 50 to 750°F ( 0 to 400°C) (GA Range only)
FT for 400 to 1200°F (GA Range only)
DT for 400 to 1200°F (200 to 650°C) (GA Range only)
70 for 200 to 450°F (GA Range only)
71 for 200 to 450°F (100 to 230°C) (GA Range only)

(4) Capillary and Bulb select from:
A for Capillary and bulb material copper.
C for Capillary and bulb material copper. Capillary protection bronze braid
D for Capillary and bulb material 316 SS.
E for Capillary and bulb material 316 SS. Capillary protection SS armor

(5) Capillary Length (For custom length contact our sales team for pricing) select from:
05 for 5 Feet
10 for 10 Feet
25 for 25 Feet

(6) Process Connection select from:
J1 for Connection type none (plain bulb)
K2 for Connection type 1/2 NPT union. Material Brass
L2 for Connection type 1/2 NPT union. Material 316 SS
M2 for Connection type 1/2 NPT union jam nut and bendable extension. Material 316 SS
J2 for Connection type Jam nut only (required with thermowell). Material Brass
J3 for Connection type Jam nut only (required with thermowell). Material 316 SS

(7) Lens select from:
Nothing(leave field blank) for None
-Glass for Glass lens
-Poly for Polycarbonate Lens
Note: All combinations may not be valid, check spec sheet for valid part numbers.