Cart  |  Contact  |  Help  |  Francais  | 
1-888-826-6342  | 
Canada1-888-826-6342
International514-856-6928

Your One-Stop Source for Process Measurement & Control!

Wireless Sensor System IEEE 802.11 b/g / Wi-Fi Transmitters

wSeries

Wireless Sensor System IEEE 802.11 b/g / Wi-Fi Temperature Transmitters | wSeries

CAD375.00 wTHP2-LCD-CCELL

1 year warranty CE
  • Web Server
  • Virtual Coordinator Data Logging Software
  • Alarms by Email or Text Message
  • Gadgets for your Desktop
  • Temperature
  • Humidity
  • Barometric Pressure
  • Dual Thermocouple Input
  • Analog Process Voltage and Current Inputs
  • NEMA 4 (IP65) Enclosure
Wireless Sensors, Transmitters, Receivers, Meters & Controllers - View related products

Description

The new OMEGA® wSeries transmitters communicate on a standard Wi-Fi network which is an ideal and economical solution for facilities with an existing Wi-Fi network as well as new installations.

Omega offers Wi-Fi transmitters for Analog Voltage and Current, Temperature from digital sensors and dual Thermocouples, Humidity, and Barometric Pressure.

Included with Wireless Sensor System is the Virtual Coordinator, a data logging software application running on a computer on the network. The "VC" collects and logs data from the transmitters and serves it to Web browsing clients.


wSeries
You can view charts and graphs, monitor and record readings from virtually any type of transducer over an Ethernet network or the Internet from any computer, tablet, or smart phone with a Web browser.

The Wi-Fi transmitters are powered by your choice of batteries or AC. The battery version comes with two ordinary alkaline "C-Cell" batteries that can last for two years depending on the frequency of readings. The AC version comes with a universal AC adapter that operates on any voltage worldwide (110 to 240 VAC) and also includes an alkaline AA backup battery.

The wSeries Wi-Fi transmitters are designed for demanding industrial applications and harsh outdoor environments. The electronics are protected in a rugged weatherproof, polycarbonate NEMA 4 (IP65) rated housing.

Alarm and Email
The wSeries wireless sensor system can trigger an alarm if variables go above or below a set point that you determine. You can even set alarms to be notified by email. Alarms can be sent to a single user or to a group distribution list, including text messages to cell phones.


Charts and Graphs
The wSeries system serves Active Web Pages to display real time readings and charts of Analog Voltage and Current, Temperature, Humidity, and Barometric Pressure. You can also log data in standard data formats for use in a spreadsheet or data acquisition program such as Excel or Visual Basic.

Chart scales are fully adjustable on the fly. For example, the chart can display one minute, one hour, one day, one week, one month or one year. Temperature and humidity can be charted across the full span (-40 to 125°C, and 0 to 100% RH) or within any narrow range such as (20 to 30°C). Omega offers an OPC Server software that makes it easy to integrate the wSeries wireless sensor system with many popular Data Acquisition and Automation programs offered by Omega, Wonderware, iConics, Intellution, Rockwell Automation, and National Instruments, among others.
Charts and Graphs

Gadgets
Another way to display your data is by using our gadget feature. This is a convenient way to view your process without keeping a web browser open, and you can display multiple IP addresses. The values are always visible while you are working on your other computer tasks. It will automatically start when you restart your computer.
Download the gadget from our software download page.

Gadgets

Quality and Technology
The innovative Omega® wSeries system features an extended one (1) YEAR warranty at no extra charge.


Ethernet Computer Network

SPECIFICATIONS
EXTERNAL SENSOR SPECIFICATIONS

RELATIVE HUMIDITY
Accuracy/Range:
wTHP, wTHP2, wBTHP

±2% for 10 to 90%;
±3% for 5 to 10% and 90 to 95%;
±4% for 0 to 5% and 95 to 100%
Hysteresis: ±1% RH
Non-linearity: ±3%
Repeatability: ±0.1%
Resolution: 0.1%

TEMPERATURE
Accuracy/Range*:
wTHP, wTHP2

±0.5°C for 5 to 45°C (±0.9°F for 41 to 113°F);
up to ±1.5°C for -40 to 5°C and 45 to 124°C
(up to ±2.7°F for -40 to 41°F and 113 to 255°F)
wTP1, WTP2
±0.5°C for 10 to 85°C (±0.9°F for 50 to 185°F);
±1°C for -40 to 10°C and 85 to 125°C
(±1.8°F for -40 to 50°F and 185 to 257°F)
wBTHP
±0.5°C for 5 to 45°C (±0.9°F for 41 to 113°F);
up to ±1.5°C for -40 to 5°C and 45 to 85°C
(up to ±2.7°F for -40 to 41°F and 113 to 185°F)
wBTP
±0.8°C @ 25ºC (±1.5°F @ 77ºF)
±4°C for -40 to 85°C (±7.2°F for -40 to 185ºF)
*Note: extended temperature range is
for External Probe only.

Resolution: 0.1ºC

BAROMETRIC PRESSURE
Accuracy/Range:
wBTP, wBTHP
±2 mbar for 300 to 1100 mbar @ 0 to 50°C
±6 mbar for 300 to 1100 mbar @ -40 to 85°C
Resolution: 0.1 mbar

ANALOG VOLTAGE & CURRENT INPUT (wVI)
Voltage Input: Differential; bipolar; ±100 mV, ±1 V, ±10 V
Input Impedance: 38 K ohm for voltage
Current Input: Differential; bipolar; ±20 mA (5 Ohm load)
Accuracy: ±0.1% Full Range @ 25°C
Reading Rate: Periodic (1 sample/update)
or continuous (3 samples/second)
A/D Conversion: Sigma-Delta
Resolution: 16 bits
Temperature Coefficient: ±50 ppm/°C
Common Mode Rejection: 105 dB
Normal Mode Rejection: 98 dB
Warm-Up to Rated Accuracy: 30 minutes

THERMOCOUPLE INPUT (wTC)
Temperature Range: refer to Thermocouple Chart
Temperature Accuracy: refer to Thermocouple Chart
Temperature Stability: 0.08°C/°C
Temperature Coefficient: ±25 ppm/°C Thermocouple Cold End Tracking: 0.1°C/°C
Thermocouple Lead Resistance: 100 ohm max.
Thermocouple Type (ITS 90):
J, K, T, E, R, S, B, C, N, L (DIN J)
Warm-Up to Rated Accuracy: 30 minutes
Reading Rate:Periodic (1 sample/update)
or continuous (3 samples/second)

METER SPECIFICATIONS

Supported Protocols Transmitter:
TCP/IP, UDP, ARP, ICMP, DHCP, HTTP and FTP
Supported Protocols VC:
TCP/IP, UDP, HTTP, FTP, SMTP and Telnet

WIRELESS COMMUNICATION
Standard: IEEE 802.11 b/g / Wi-Fi
Frequency: 2.4 GHz (2402~2480 MHz)
Range: 60 m (200') indoor line-of-site or more depending upon sensitivity, data rate, wireless access point, and environmental considerations
Radio Power Output Level (Class 1):
91.4 mW EIRP (19.6 dBm EIRP)
Modulation:
  802.11b Compatibility: DSSS
  (CCK-11, CCK-5.5, DQPSK-2, DBPSK-1)
  802.11g: OFDM (default)
Channels: 1 to 13; Channel 14 for Japan use only and is not certified
Channel Spacing (Bandwidth): 20 MHz, refer to manual
Transmission Rate (over the air):
  802.11b: 1 to 11 Mbps
  802.11g: 6 to 54 Mbps
Receiver Sensitivity: -85 dBm, typ.

POWER (wSeries AC POWER)
Power Input: 5 Vdc
Consumption: 0.7 W max
Safety Qualified AC Power Adapter (included)
  Nominal Output:
  5 Vdc @ 0.6 A
  Input:
  100 to 240 Vac, 50/60 Hz
Back-up Alkaline Battery: One AA 1.5 Vdc, supplied
Universal ac Power Adapter
Universal ac Power Adapter

POWER (wSeries-CCELL) Alkaline Battery:
Two C-CELL 1.5 Vdc, supplied
Lifetime:
Estimate of 2.4 years (wTC/wVI) and 4.3 years (wTxxP/wBxxP) with frequency of 1 reading per 1 minute (see Chart)
Caution!

Battery life is dependent on environmental conditions and transmitter settings.

ENCLOSURE PACKAGING
Material: Polycarbonate
Protection: NEMA 4 (IP65) rated housing
Dimensions: 96.5H x 146.3W x 50.8D mm
(3.8 x 5.76 x 2"), not including connectors or antenna

GENERAL
Approvals: FCC Part 15C; CE EMC; 2004/108/EC, LVD 2006/95/EC, R&TTE 1999/5/EC
Operating Temperature:
-10 to 55ºC (14 to 131ºF), 90% RH non-condensing
  AC Power Adapter: 0 to 40ºC (32 to 104ºF)

2 Thermocouples included with WTC models

Introduction to Thermocouples

Optional Caps available for Industrial Probes
2 Thermocouples included
with WTC models
Introduction
to Thermocouples
Optional Caps available
for Industrial Probes

ESTIMATED ALKALINE BATTERY LIFETIME CHART
Estimated Alkaline Battery Lifetime
Update Rate
C Cell Units
AA Back-Up/AC Units
Continuous* (wTC, wVI)
2 weeks
2 days
10 seconds* (default)
9.6 to 20.5 months
4 weeks
1 Minute
2.4 to 7 years
3.6 to 9.6 months
2 Minute
4.3 to 7 years
6 months to 1.5 years
* Power Save mode
Click HERE for detailed Battery Lifetimes
Caution!
Battery life is dependent on environmental conditions and transmitter settings.
THERMOCOUPLE CHART

Input Type
Range
Accuracy
J
Iron-Constantan
-210 to 760°C / -346 to 1400°F
0.5°C / 0.9°F
K
CHROMEGA®-ALOMEGA®
-230 to -180°C / -180 to 1372°C
-382 to -292°F / -292 to 2502°F
1.0°C / 0.5°C
1.8°F / 0.9°F
T
Copper-Constantan
-240 to -180°C / -180 to 400°C
-400 to -292°F / -292 to 752°F
1.0°C / 0.5°C
1.8°F / 0.9°F
E
CHROMEGA®-Constantan
-250 to -220°C / -220 to 1000°C
-418 to -364°F / -364 to 1832°F
1.0°C / 0.5°C
1.8°F / 0.9°F
R
Pt/13%Rh-Pt
310 to 1768°C
590 to 3214°F
1.0°C
1.8°F
S
Pt/10%Rh-Pt
400 to 1768°C
752 to 3214°F
1.0°C
1.8°F
B
30%Rh-Pt/6%Rh-Pt
470 to 1050°C / 1050 to 1820°C
878 to 1922°F / 1922 to 3308°F
2.0°C / 1.0°C
3.6°F / 1.8°F
C
5%Re-W/26%Re-W
0 to 450°C / 450 to 790°F
790 to 2280°C / 32 to 842°F
842 to 1454°C / 1454 to 4136°F
1.0°C / 0.5°F
1.0°C / 1.8°F
0.9°C / 1.8°F
N
Nicrosil-Nisil
-200 to -120°C / -120 to 1300°C
-328 to -184°F / -184 to 2372°F
1.0°C / 0.5°C
1.8°F / 0.9°F
L
J DIN
-200 to 900°C / -328 to 1652°F
0.5°C / 0.9°F

REPLACEMENT PROBES & CALIBRATION CERTIFICATES
No need to take your unit out of service to get re-calibrated, order a calibrated probe instead.
Probes NIST Certificate

Get a NIST Traceable Calibration Certificate
with your Calibrated Replacement Probe.
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Part Number/ Desc.
Qty
Description
  
wTP1-LCD Star
CAD319.00
Availability: 1 week
 
Temperature sensor with stick probe, AC powered, LCD display
  
wTP2-LCD Star
CAD319.00
Availability: 1 week
 
Temperature sensor with lug mount probe, AC powered, LCD display
  
wTHP-LCD Star
CAD375.00
Availability: 1 week
 
Temperature and humidity sensor, AC powered, LCD display
  
wTHP2-LCD Star
CAD375.00
Availability: 1 week
 
Temperature and humidity sensor, short probe, AC powered, LCD display
  
wBTHP-LCD Star
CAD445.00
Availability: 1 week
 
Barometric pressure, temp and humidity sensor, AC powered, LCD display
  
wTC-LCD-CCELL Star
CAD375.00
Availability: 1 week
 
Wireless Transmitter: Dual thermocouple inputs, battery powered, LCD display
  
wVI-LCD-CCELL Star
CAD363.00
Availability: 1 week
 
Wireless Transmitter: Analog input, battery powered, LCD display
Replacement Probes
  
zTP1-P Star
CAD63.00
Availability: 1 week
 
External stick probe with temperature sensor, 3 m (10') cable
  
zTP2-P Star
CAD63.00
Availability: 1 week
 
External lug mount probe with temperature sensor, 3 m (10') cable
  
zTHP-P Star
CAD119.00
Availability: 1 week
 
External industrial probe with temperature and humidity sensor, 3 m (10') cable
  
zTHP2-P Star
CAD119.00
Availability: 1 week
 
External short industrial probe with temperature and humidity sensor
  
wBTP-P Star
CAD125.00
Availability: 1 week
 
External industrial probe with barometric pressure, temperature sensor, 3 m (10') cable
  
wBTHP-P Star
CAD181.00
Availability: 1 week
 
External industrial probe with barometric pressure, temp and humidity sensor, 3 m (10') cable
Calibration for New Units
Click to expand/minimize a list of what others bought with theCAL-3-HU
CAL-3-HU Star
Consult Sales  
Availability: 
 
 
NIST Traceable Calibration Certificate. Three Humidity Points: 25%, 50%, 75%, One Temperature Point 25°C (for new units)
Click to expand/minimize a list of what others bought with theCAL-3-HU-P-T
CAL-3-HU-P-T Star
Consult Sales  
Availability: 
 
 
NIST Traceable Calibration Certificate. Three Humidity , Barometric Pressure, and Temperature Points (for new units)
  
CAL-3-P Star
Consult Sales  
Availability: 
 
 
NIST Traceable Calibration Certificate. Three Barometric Pressure Points and one temperature 25°C (for new units)
  
CAL-3-T Star
Consult Sales  
Availability: 
 
 
NIST Traceable Calibration Certificate. Three Temperature Points (for new units)
Click to expand/minimize a list of what others bought with theCT485B-CAL-KIT
CT485B-CAL-KIT Star
CAD100.00
Availability: 1 week
 
Calibration Kit, 33% and 75% RH Standards
Calibrated Replacement Probes, including Calibration Certificate
  
zTP1-P-CAL-3-T Star
CAD160.00
Availability: 1 week
 
Replacement External Stick Probe with Temperature Sensor, cable 3m (10 ft) NIST Traceable Calibration Certificate. Three (3) Temperature Points
  
zTP2-P-CAL-3-T Star
CAD156.00
Availability: 1 week
 
Replacement External Lug Mount Probe with Temperature Sensor, cable 3m (10 ft) NIST Traceable Calibration Certificate. Three (3) Temperature Points
  
zTHP2-CAL-3-HU Star
CAD213.00
Availability: 1 week
 
Replacement External Short Industrial Probe with Temperature and Humidity Sensor, with NIST Traceable Calibration Certificate. Three (3) Humidity Points of 25%, 50%, 75%, one temperature 25°C.
  
wBTP-P-CAL-3-P Star
CAD219.00
Availability: 1 week
 
Replacement External Industrial Probe with Barometric Pressure and Temperature Sensor, cable 3m (10 ft) with NIST Traceable Calibration Certificate. Three (3) Barometric Pressure Points, one temperature 25°C.
  
wBTHP-P-CAL-3-HU-P-T Star
CAD465.00
Availability: 1 week
 
Replacement External Industrial Probe with Barometric Pressure, Humidity and Temperature Sensor, cable 3m (10 ft) with NIST Traceable Calibration Certificate. Three (3) humidity, barometric pressure, and temperature points
Accessories
Click to expand/minimize a list of what others bought with theIP-PCI-10P
IP-PCI-10P Star
CAD25.00
Availability: 1 week
 
Porous Polyethylene Industrial Probe Cap, for wet environments, 10 pack. For external industrial probes only.
Click to expand/minimize a list of what others bought with theIP-SC
IP-SC Star
CAD31.50
Availability: 1 week
 
Porous Stainless Steel Probe Cap, 5um porosity, for dusty and pressurized (less than 35 psi) environments. For external industrial probes only.
  
IND-KIT Star
CAD9.40
Availability: 1 week
 
Replacement Mounting Kit, for external industrial probes.
All dollar amounts on this site are shown in Canadian currency. Note: Comes complete with 2 "CCELL" batteries or AC power adaptor, and "AA" backup battery.

Note: Two type K thermocouples with 1 m of 24 AWG PFA insulated wire with stripped lead termination included with WTC models.

Note: Because of transmission frequency regulations, these products may only be used in the United States, Canada and Europe.


Ordering Example: (2) WTP1-LCD wireless transmitters with LCD, AC power and external temperature sensor with 3 m (10') cable, CAD319.000   plus (1) ZTP1-CAL-3-T For a calibrated replacement probe including Calibration Certificate, CAD127.00, CAD319.00 X 2 + 127.00 = CAD765.00

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) External Sensors select from:
TP1 for Temperature Stick Probe
TP2 for Temperature Lug Mount Probe
THP for Humidity + Temperature Industrial Probe
THP2 for Short Quick-Disconnect Humidity + Temperature Probe
BTHP for Barometric Pressure + Temperature + Humidity Industrial Probe
BTP for Barometric Pressure + Temperature Industrial Probe
TC for Dual Thermocouple Input
VI for Analog Process Voltage and Current Input

(2) Power and Display Options select from:
-LCD for AC power and LCD Display
-LCD-CCELL for Power with two C-cell alkaline batteries and LCD Display
Note: All combinations may not be valid, check spec sheet for valid part numbers.

Product Manuals:

Download wSeries - Wireless Transmitter Setup Guide
Download wSeries - Wireless Sensor System User Guide