DIN Rail 2-Wire Temperature Transmitters

C$284.00

Item# DRA-TCI-2-S

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 C$284.00
5-9 C$269.80
10-24 C$264.12
25-49 C$252.76
50-99 C$247.08
100+ C$241.40

In stock

Lead Time ( If not in Stock): 99 weeks

DIN Rail 2-Wire Temperature Transmitters DRA-TCI-2-S DRA-TCI-2-S
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • DRA-TCI-2 Thermocouple Input Model
  • DRA-RTI-2 RTD Input Model
  • Isolated
  • Linearized
  • Field Rangeable

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Number of Inputs
Input Type
Input Ranges
Output Type


Product Specs

  • Accuracy Value ±0.08% of span for type K
  • Form Factor 35 mm DIN rail
  • Maximum Ambient Humidity 95% RH non-condensing
  • Maximum Ambient Temperature 70 {C} (158 {F})
  • Minimum Ambient Temperature -20 {C} (-4 {F})
  • Maximum Storage Temperature 85 {C} (185 {F})
  • Minimum Ambient Humidity 5% RH
  • Minimum Storage Temperature -30 {C} (-22 {F})
  • RTD Connection 2-Wire or 3-Wire
  • RTD Curves Supported alpha = 0.00385
  • Form Factor 35 mm DIN rail
  • Accuracy Value ±0.08% of span for type K
  • Maximum Storage Temperature 85 {C} (185 {F})
  • Maximum Ambient Humidity 95% RH non-condensing
  • Maximum Ambient Temperature 70 {C} (158 {F})
  • Minimum Ambient Humidity 5% RH
  • Minimum Ambient Temperature -20 {C} (-4 {F})
  • Minimum Storage Temperature -30 {C} (-22 {F})
  • RTD Connection 2-Wire or 3-Wire
  • RTD Curves Supported alpha = 0.00385

Models DRA-TCI-2 and DRA-RTI-2 are linearized temperature transmitters that produce a 4-20 mA process signal that is directly proportional to temperature. These transmitters have exceptionally high input to output common mode rejection (CMR), a high degree of filtering that eliminates false output signals and provides a low ripple current. Model DRA-TCI-2 is available for thermocouple types J, K, T, E, R, S or B and provides exceptional temperature linearization by applying eight segment linearization circuitry. Model DRA-RTD-2 accepts 2 or 3 wire Pt-100 RTDs, alpha = 0.00385. Both models are field rangeable using a set of six internal dip switches for coarse ranging and front accessible zero and span potentiometers for fine adjustment. Test terminals are provided to monitor the transmitter’s 4-20 mA output without disturbing the actual process loop.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Hi, is there a manual for the DRA-RTI-2 model? I see the manual on the website for the DRA-TCI-2 model only. Thanks.

Asked by: aenc
Thank you for your question. See link for DRA-RTI-2 manual: https://www.omega.com/en-us/pdf-manuals
Answered by: PVDAS
Date published: 2020-04-14
  • y_2020, m_9, d_20, h_15CST