10 Products found
thumbnail

The CDCN-91 series dual channel conductivity/resistivity controller is a two-channel input device equipped with three scalable 4 to 20 mA outputs and four programmable rela... Read More

CDCN91
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits
5   In Stock
Conductivity 0.055 to 400,000 μS/cm, Resistivity 10 k1/2/cm to 18.26 M1/2/cm (0.055 to 100 μS/cm)
100 to 240 Vac
1
4 to 20 mA
1/4 DIN
2 x 16 Digit
thumbnail

The CDH-93 resistivity and conductivity meter uses advanced automatic frequency conversion and booster technology to keep the electrode constant the same in different solut... Read More

CDH-93-series
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits
43   In Stock
Conductivity 5.0 to 50.0μ S/cm, 50 to 500μ S/cm, 0.5 to 5.00 mS/cm, 5.0 to 50.0 mS/cm, Resistivity 2.0 to 20 MΩ-cm
Not Applicable
Not Applicable
Not Applicable
Handheld
Not Applicable
thumbnail

The CDCN441 conductance/resistance analyzercontroller is designed for online monitoring of process solutions and water applications. Applications include: waste water treat... Read More

CDCN441-series
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits
Available in 8 weeks
0.1 μS to 20 mS, K = 0.1, 0 to 130°C (32 to 266°F), 10 kg/cm2
90/240 Vac
1
2 N.O. (1A/240 Vac) on/off alarm or PWM 4 to 20 mA for PID control or retransmission
Wall Mount
2 lines x 16 characters
Available in 8 weeks
0.01 μS to 2mS, K = 0.01, 0 to 100°C (32 to 212°F), 10 kg/cm2
90/240 Vac
1
2 N.O. (1A/240 Vac) on/off alarm or PWM 4 to 20 mA for PID control or retransmission
Wall Mount
2 lines x 16 characters
Available in 8 weeks
0.1 μS to 100 mS, K = 1, 0 to 130°C (32 to 266°F), 10 kg/cm2
90/240 Vac
1
2 N.O. (1A/240 Vac) on/off alarm or PWM 4 to 20 mA for PID control or retransmission
Wall Mount
2 lines x 16 characters
Available in 8 weeks
1 μS to 150 mS, K = 5, 0 to 130°C (32 to 266°F), 10 kg/cm2
90/240 Vac
1
2 N.O. (1A/240 Vac) on/off alarm or PWM 4 to 20 mA for PID control or retransmission
Wall Mount
2 lines x 16 characters
1   In Stock
Not Applicable
90/240 Vac
2
Relay, 4 to 20 mA
Wall Mount
2 lines x 16 characters
show More  Load More Items from this family (1) ...
thumbnail

The CDCN-961 conductance, resistance or total dissolved solids (TDS) controller is designed for inline monitoring of process solutions and water applications. T... Read More

CDCN-961-series
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits Cell Constants
5   In Stock
Conductivity 0.000 to 3.000, 30.00, 300.0 μS/cm / mS/cm Resistivity 0.3 to 30.0 MΩcm 3 to 300 MΩcm TDS 0.000 to 3.000, 30.00,300.0 ppm / ppt
Not Applicable
1
0.4 to 20 mA
Not Applicable
Not Applicable
0.01, 0.1, 1, 10
thumbnail

The OMEGA™ CDH-SD1 is innovative and easy to operate. What sets the CDH-SD1 apart from other conductivity meters is that it incorporates a real-time SD card data logger. Th... Read More

CDH-SD1-series
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits
Available in 10 weeks
Conductivity 200 uS, 2, 20, or 200 mS, TDS 200, 2000, 20,000, or 132,000 PPM, Salt 0 to 12% (% by weight)
Not Applicable
Not Applicable
Not Applicable
Handheld
Not Applicable
thumbnail

The CDCN442 toroidal conductivity system isdesigned for online monitoring of chemically aggressive process solutions, water applications that coat or foul traditional senso... Read More

CDCN442-series
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits Cell Constants
Available in 8 weeks
1 mS to 1 S
90/240 Vac
1
4 to 20 mA
Wall Mount
2 x 16 Digit
0.01, 0.1, 1 or 5/10 cm-1
Available in 8 weeks
Conductivity Range 10 mS/cm to 1 S/cm, Resistivity Range 10 MΩ/cm to infinity
90/240 Vac
1
4 to 20 mA
Wall Mount
2 x 16 Digit
0.01, 0.1, 1 or 5/10 cm-1
thumbnail

The PHUCN600 Series multi-parameter controller is a microprocessor-based controller capable of measuring one of the following parameters, pH, ORP, or conductivity. Wh... Read More

PHUCN600
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits
2   In Stock
pH 0.01 to 14.00 pH -5 to 95°C (23 to 203°F), ORP -1999 to 1999 mV -5 to 95°C (23 to 203°F)
16 to 32 Vdc
1
4 to 20 mA
1/4 DIN, Panel Mount
Not Applicable
2   In Stock
pH 0.01 to 14.00 pH -5 to 95°C (23 to 203°F), ORP -1999 to 1999 mV -5 to 95°C (23 to 203°F)
110 Vac
1
4 to 20 mA
Panel
Not Applicable
3   In Stock
pH 0.01 to 14.00 pH -5 to 95°C (23 to 203°F), ORP -1999 to 1999 mV -5 to 95°C (23 to 203°F)
220 Vac
1
4 to 20 mA
Panel
Not Applicable
thumbnail

This microprocessor-based family of pH panel mounted controller is designed for a wide variety of environmental monitoring applications. The units features automatic or man... Read More

PHCN37
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits Additional Features
Available in 4 weeks
0 to 14.00 pH 0 to 100°C (32 to 212°F)
230 Vac
Not Applicable
Not Applicable
1/8 DIN
4 Digit
Isolated Analog Output
Available in 4 weeks
0 to 14.00 pH 0 to 100°C (32 to 212°F)
115 Vac
Not Applicable
Not Applicable
1/8 DIN
4 Digit
Isolated Analog Output
26   In Stock
0 to 14.00 pH 0 to 100°C (32 to 212°F)
230 Vac
Not Applicable
Not Applicable
1/8 DIN
4 Digit
Standard
Available in 4 weeks
0 to 14.00 pH 0 to 100°C (32 to 212°F)
10/32 Vdc
Not Applicable
Not Applicable
1/8 DIN
4 Digit
Standard
Available in 4 weeks
0 to 14.00 pH 0 to 100°C (32 to 212°F)
115 Vac
Not Applicable
Not Applicable
1/8 DIN
4 Digit
Standard
show More  Load More Items from this family (5) ...
thumbnail

Electronics are available in various configurations for maximum installation flexibility. The universal-mount version is for pipe, wall, or tank mounting and uses the CDCE-... Read More

CDTX-2850
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits Cell Constants Additional Features
Available in 6 weeks
Not Applicable
12 to 24 Vdc
1
4 to 20 mA
Junction box for integral mount PBT
Not Applicable
10
Manufactured under ISO 9001 and ISO 14001
Available in 6 weeks
Not Applicable
12 to 24 Vdc
1
4 to 20 mA
Junction box for integral mount PBT
Not Applicable
Not Applicable
Threaded J-box
Available in 6 weeks
Not Applicable
12 to 24 Vdc
1
4 to 20 mA
Junction box for integral mount PBT
Not Applicable
1
Manufactured under ISO 9001 and ISO 14001
Available in 6 weeks
Not Applicable
12 to 24 Vdc
1
4 to 20 mA
Junction box for integral mount PBT
Not Applicable
0.01
Manufactured under ISO 9001 and ISO 14001
2   In Stock
Not Applicable
12 to 24 Vdc
1
4 to 20 mA
Junction box for integral mount PBT
Not Applicable
0.01
Not Applicable
show More  Load More Items from this family (5) ...
thumbnail

Industrial process conductivity/temperature controllers CDTX-111 and CDTX-112 are panel instruments for in-process monitoring of conductivity. Range switch over and cell co... Read More

CDTX-111-CDTX-112
Price Stock Range Supply Voltage Number of Control Outputs Control Output Type Form Factor Number of Display Digits
34   In Stock
0 to 199.9 μS/cm 0 to 1999 μS/cm
110 V to 220 V
1
Isolated, 4 to 20 mA
Panel
Not Applicable
11   In Stock
0 to 999.9 μS/cm 0 to 9999 μS/cm, 0 to 100mS/cm, 0 to 600 mS/cm
110 V to 220 V
1
Isolated, 4 to 20 mA
Panel
Not Applicable