en
Save Configuration
text.skipToContent text.skipToNavigation
Configure Product
Saved Configuration
View Configuration
Terms and Conditions

PID Controllers

449 Products found
thumbnail

DescriptionThe CN7200 Series ¼DINtemperature/process controllers aredesigned to accept thermocouple,RTD, current or voltage input andprovide dual outputs for control.Av... Read More

CN72000
Price Stock Accuracy Control Output Type Display Type Form Factor Input Type Maximum Ambient Temperature Minimum Ambient Temperature Number of Control Outputs Number of Display Digits Number of Inputs Other Features Output Mode Ramp & Soak Capability Supply Voltage Thermocouple Type
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 AC SSR/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Single output relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
1.0
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 AC SSR/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 0 to 20mA and relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Single output 0 to 20mA with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
1
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 5 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 AC SSR/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 5 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 5 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 AC SSR/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 AC SSR/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 0 to 20mA and relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Single output relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
1
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 5 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 5 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 5 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
2  In Stock
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 0 to 20mA and relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 AC SSR/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 2 relay/DC Pulse with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output two 0 to 20mA with alarm
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 0 to 20mA and relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
Available in 6 weeks
±0.25% of span, ±1 least significant digit
Dual output 0 to 20mA and relay/DC Pulse
Dual LED
1⁄4 DIN
Thermocouple, RTD, DC voltage, DC current
55°C (131°F)
-10°C (14°F)
2
4 Digit, 7 Segment
4.0
Recorder Retransmission Fuzzy Logic
on/off PID heat/cool or latching alarm
Yes
100 to 240 Vac
J K E T L N B C S R
thumbnail

Monitor and control temperature or process applicationswith precision using the CN7800 Series controllers. TheCN7800 Series provides dual LED displays fo... Read More

CN7800-Series
Price Stock Accuracy Communication Protocols Control Output Assignment Control Output Type Display Type Form Factor Input Type Maximum Ambient Temperature Minimum Ambient Temperature Number of Control Outputs Number of Display Digits Number of Inputs Output Mode Ramp & Soak Capability Resolution Supply Voltage Thermocouple Type
9  In Stock
±0.25% span ±1 least significant digit
RS485 Modbus® A-5-11/RTU communication protocol
2 Alarm
Relay, Relay
Dual LED
1/16 DIN
Thermocouple, RTD, DC voltage, DC current
50°C (122°F)
0°C (32°F)
2
4 Digit, 7 Segment
4.0
PID ON/OFF Manual or PID program control
Yes
1.0 0.1 for thermocouples
100 to 240 Vac
K J N T E N R S B L U
26  In Stock
±0.25% span ±1 least significant digit
RS485 Modbus® A-5-11/RTU communication protocol
2 Alarm
DC Pulse, Relay
Dual LED
1/16 DIN
Thermocouple, RTD, DC voltage, DC current
50°C (122°F)
0°C (32°F)
2
4 Digit, 7 Segment
4.0
PID ON/OFF Manual or PID program control
Yes
1.0 0.1 for thermocouples
100 to 240 Vac
K J N T E N R S B L U
13  In Stock
±0.25% span ±1 least significant digit
RS485 Modbus® A-5-11/RTU communication protocol
2 Alarm
4 to 20mA Relay
Dual LED
1/16 DIN
Thermocouple, RTD, DC voltage, DC current
50°C (122°F)
0°C (32°F)
2
4 Digit, 7 Segment
4.0
PID ON/OFF Manual or PID program control
Yes
1.0 0.1 for thermocouples
100 to 240 Vac
K J N T E N R S B L U
thumbnail

DescriptionThe PHCN-961/962 series of pH controller andtransmitter provides a reliable method of monitoringand controlling pH in water treatment, electrolyticwater clea... Read More

PHCN-961-Series
Price Stock Accuracy Communication Protocols Control Output Assignment Control Output Type Display Type Form Factor Input Type Maximum Ambient Temperature Minimum Ambient Temperature Number of Control Outputs Number of Display Digits Number of Inputs Ramp & Soak Capability Resolution Supply Voltage
Available in 11 weeks
pH Accuracy ±0.01 pH mV Accuracy ±1 mV Temperature Accuracy ±0.5°C
RS485 client program
2 Alarm
Relay, Analog
LCD
Wall-mount
pH Voltage Temperature
50°C (122°F)
-10°C (14°F)
2.0
4 Digit
3.0
No
pH Resolution 0.01 pH mV Resolution 1 mV Temperature Resolution 0.1°
110 or 220 Vac
Available in 9 weeks
pH Accuracy ±0.01 pH mV Accuracy ±1 mV Temperature Accuracy ±0.5°C
RS485 client program
2 Alarm
Relay, Analog
LCD
Panel Mount
pH Voltage Temperature
50°C (122°F)
-10°C (14°F)
2.0
4 Digit
3.0
No
pH Resolution 0.01 pH mV Resolution 1 mV Temperature Resolution 0.1°
110 or 220 Vac
thumbnail

DescriptionThe OMEGA™ 4000A Series digital controller distinguishes itself by features, construction, and operation one would expect to find only in controllers costing... Read More

4000A
Price Stock Accuracy Control Output Assignment Control Output Type Display Type Form Factor Input Type Maximum Ambient Temperature Minimum Ambient Temperature Number of Control Outputs Number of Display Digits Number of Inputs Ramp & Soak Capability Resolution Supply Voltage Thermocouple Type
1  In Stock
±0.5% of span over 10 to 90% of range
Dual Setpoint
Relay/Relay (On/Off Only)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 4 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
Relay (Standard Model)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
J
2  In Stock
±0.5% of span over 10 to 90% of range
Single Setpoint
Relay (Standard Model)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
DC Pulse
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Single Setpoint
Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Single Setpoint
Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Single Setpoint
Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Single Setpoint
DC Pulse
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Single Setpoint
Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Dual Setpoint
Relay/Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Dual Setpoint
Relay/Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Dual Setpoint
Relay/Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Dual Setpoint
Relay/Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Dual Setpoint
Relay/Relay (On/Off Only)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Dual Setpoint
Relay/Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Dual Setpoint
Relay, DC Pulse
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Dual Setpoint
Relay/Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Dual Setpoint
Relay/Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
K
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
DC Pulse
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
Triac
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
Available in 5 weeks
±0.4% of span over 10 to 90% of range
Dual Setpoint
Relay/Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
J
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Dual Setpoint
Relay/Current Proportional
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
K
2  In Stock
±0.5% of span over 10 to 90% of range
Single Setpoint
Relay (Standard Model)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
K
Available in 5 weeks
±0.5% of span over 10 to 90% of range
Single Setpoint
DC Pulse
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
K
4  In Stock
±0.4% of span over 10 to 90% of range
Dual Setpoint
Relay/Relay (On/Off Only)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
Available in 4 weeks
±0.4% of span over 10 to 90% of range
Single Setpoint
Relay (Standard Model)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
1.0
3 or 3 1⁄2 Digits
1.0
No
1°F
120/240 Vac
J
1  In Stock
±0.4% of span over 10 to 90% of range
Dual Setpoint
Relay/Relay (On/Off Only)
Filtered LED
1/4 DIN Metal Case
Thermocouple
54°C (130°F)
-1°C (30°F)
2.0
3 or 3 1⁄2 Digits
1.0
No
1°C
120/240 Vac
J
thumbnail

DescriptionThe CN3261 Series High LimitController protects expensiveheaters and sensitive materials fromdamaging over temperatureconditions. It is designed forindustria... Read More