Skip to search Skip to main content Skip to navigation

Call us at 1-888-826-6342

We noticed you are from . Visit your local site for regional offers and live support.

1/32, 1/16, and 1/8 DIN Universal High Performance Controllers

Platinum Series Versatile High Performance PID Controllers

C$482.23

Item# CN32PT-330

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-9 C$482.23
10-24 C$458.12
25-49 C$434.01
50-99 C$409.90
100-499 C$385.78
500+ C$361.67

In stock

Lead Time (If not in stock): 6 weeks
Platinum Series Versatile High Performance PID Controllers CN32PT-330 CN32PT-330
  • Strain & Bridge Inputs, 6 Digit Display and Upgraded Platinum Software Now Available
  • Industry Leading Performance (20 Samples / Sec), High Accuracy
  • Up to 6 Programmable Control/Alarm/Re-transmission/Relay Outputs
  • Full Autotune PID with Fuzzy Logic Adaptive Control
  • Up to 99 Programs with 16 Ramps and Soaks and Chaining
  • No Jumpers to Set, Totally Firmware Configurable
  • USB Communications Standard on Every Model
  • Meter and Alarm only versions also available
  • Support Heating & Cooling Control
  • Log data with Omega Enterprise Gateway(OEG)
  • CAD/STEP File download

CN32PT-330 Model Options

View all models

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Control Outputs
Form Factor
Communications
Supply Voltage Type
Display Type
Output Type
Measurement Type
Number Of Inputs
Input Type
Ramp And Soak
Additional Feature


The Platinum Series family of microprocessor-based PID controllers offer unparalleled flexibility in process measurement. While extremely powerful and versatile, great care has gone into designing a product that is very easy to set-up and use. The automatic hardware configuration recognition eliminates the need for jumpers and allows the firmware to automatically simplify itself, eliminating all menu options that do not apply to a specific configuration. Offered in 1⁄32, 1⁄16, and 1⁄8 DIN sizes, the 1⁄16 and 1⁄8 DIN models can be configured with dual displays.
 

 



Each unit allows the user to select the input type from 9 thermocouple types, PRT/RTD sensors, thermistors, DC voltage, DC current, and Strain & Bridge inputs. The full bidirectional voltage or current inputs are fully scalable to virtually all engineering units, with a selectable decimal point that is perfect for use with pressure, flow, or other process input.

Up to 6 programmable outputs including the isolated analogue and additional features make this the most powerful product in its class. Standard features include: remote set-point for cascaded control, high-high/low-low alarms, external latch reset, external ramp and soak initiation, combination heat/cool control mode and configuration save and transfer.

Free Downloadable Software
Free Downloadable Configurator Windows® Application Software
  • Fully Configure all PLATINUM Functions/Parameters
  • Auto-Connect Through USB Channel
  • Load/Save PLATINUM Configuration Files
  • Performance Tracking (Charting) with Data Capture

An advanced multi-stage ramp and soak sequencer supports up to 99 profiles of 8 segment ramp/soak sequences. Profiles may be linked to provide extended sequences and auxiliary outputs may be triggered based on individual Ramp or Soak states to provide external control over blowers, mixers or other auxiliary control functions.

Embedded Ethernet and Serial Communications
Optional “embedded ethernet” on the 1⁄16 and 1⁄8 DIN models allow the units to connect directly to an Ethernet network and transmit data in standard TCP/IP packets, or serve Web pages over a LAN or the Internet. Optional serial communications are also available configurable as RS232 or RS485, with straightforward ASCII commands or MODBUS®. All three types of communications interfaces can be installed and active simultaneously.

LabVIEW™ Driver
The Platinum LabVIEW™ driver is the National Instrument device driver for communicating with Omega Platinum Controllers via Modbus RTU/ASCII and Modbus TCP protocols. The driver allows easy access to the internal data, configuration settings, and operating functions of the Platinum product family.

The LabVIEW™ instrument driver reduces the application development time and simplifies instrument control. With the Platinum LabVIEW driver, customers can quickly communicate with the instrument and develop robust test applications and software.

DasyLab
Support for the easy-to-use DasyLab software solves complex data acquisition and control problems by allowing you to work with flowcharts directly on your PC screen. The high input accuracy, advanced process control, extended sequencing capability and flexible output options of a Platinum controller may be easily integrated with the rich set of function modules provide by the DasyLab software. The DasyLab software may be integrated thru the Platinum serial, Ethernet or USB connections.

Comparison Chart
Pt Series Features—PerformanceVs CompetitionBenefitsUp to 20 Input Samples per Second with 24-bit ADCBest in classImproved control for responsive systems such as flow or weight control in factory automation and process industries.Up to 99 Programs with 16 Ramps and Soaks Including Ramp/Soak Events and Remote Start. Chainable for unmatched programmability.Best in classCombines with the measurement accuracy feature to provide precise control in menu-driven applications such as plastics, food, and ceramics processing.


SPECIFICATIONS
INPUTS
Input Types: Thermocouple, RTD, Thermistor, analogue Voltage, analogue Current, Strain
Current Input: 4 to 20 mA, 0 to 24 mA scalable
Voltage Input: ±100 mV, ±1 V, ±10 Vdc single-ended, scalable; ±50 and ±100 mV differential and ratiometric inputs, scalable
Thermocouple Input (ITS 90): K, J, T, E, R, S, B, C, N
RTD Input (ITS 90): 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385, 0.00392 (100Ω only), or 0.003916 (100 Ω only) curves
Thermistor Input: 2252 Ω, 5K Ω, 10K Ω
Strain Input: ±100 mV, ±50 mV
Configuration: Differential
Polarity: Bipolar
Accuracy: See full table below
Resolution: 0.1° temperature; 10 µV process
Input Impedances:
    Process Voltage: 10M Ω for ±100 mV, 1M Ω for other voltage ranges
    Process Current: 5 Ω
    Thermocouple: 10K Ω max
    Auxiliary Input (Remote Setpoint): 3.5K Ω for 0-10 V, 50K Ω for 0-1 V, 50 Ω for Current
Temperature Stability:
    RTD: 0.04°C/°C
    Thermocouple @ 25°C (77°F): 0.05°C/°C (cold junction compensation)
    Process/Strain: 50 ppm/°C
A/D Conversion: 24-bit sigma delta
Reading Rate: 20 samples per second
Digital Filter: Programmable from 0.05 seconds (filter = 1) to 6.4 seconds (filter = 128)
CMRR: 120 dB
Excitation: Menu selectable (no jumpers to set) 5, 10, 12, and 24 Vdc @ 25 mA (12 V max for DC powered units).
Setpoint Adjustment: 4 Digit -9999 to +9999 counts; 6 Digit -99999 to +999999
Warm-Up to Rated Accuracy: 30 mins

CONTROL MODES
Action: Reverse (heat), direct (cool), or heat/cool
Auto-Tune: Operator initiated from front panel
Adaptive Tune: User selectable; fuzzy logic continuous PID tuning optimization
Control Modes: ON/OFF or the following time/amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative
Cycle Time: 0.1 to 199 seconds
Ramp and Soak: Up to 99 saved ramp and soak programs, up to 8 ramp and 8 soak segments with individually selectable events per program
Ramp and Soak Segment Times: 00.00 to 99.59 (HH:MM) or 00.00 to 99.59 (MM:SS)

CONTROL OUTPUTS
Analogue Output: Non-isolated, programmable for control or retransmission; Voltage Output 0-10V output. 500Ohms Min. Accuracy 0.1%(1); Current Output 0-20mA output. 500Ohms Max. Accuracy 0.1%(1)(2); Step response time 100ms(3)
DC Pulse: Non-isolated; 10 Vdc at 20 mA
SPST Relay: Single pole, single throw mechanical relay, 250 Vac or 30 Vdc at 3 A (resistive load)
SPDT Relay: Single pole, double throw mechanical relay, 250 Vac or 30 Vdc at 3 A (resistive load)
SSR: 20 to 265 Vac at 0.05 to 0.5 A (resistive load)
Isolated analogue: 1.5kV Isolation(4), programmable for control or retransmission; Voltage Output 0-10V output. 500Ohms Min. Accuracy 0.1%(1); Current Output 0-20mA output. 500Ohms Max. Accuracy 0.1%(1)(2); Step response time 100ms(3)
Isolated DC Pulse: 1.5kV Isolation(4); 10Vdc at 20mA
(1) At 25C.
(2) Output scaling required for stated accuracy. Refer to Platinum Current Output Application Note.
(3) Filter setting of 1.
(4) Isolated outputs not individually isolated.

COMMUNICATIONS (USB STANDARD, OPTIONAL SERIAL AND ETHERNET)
Connection:
    USB: Female micro-USB
    Ethernet: Standard RJ45
    Serial: Screw terminals
USB: USB 2.0 host or device
Ethernet Standards Compliance: IEEE 802.3 10/100 Base-T autoswitching, TCP/IP, ARP
Serial: Software selectable RS232 or RS485; programmable 1200 to 115.2 K baud
Protocols: Omega ASCII, Modbus® ASCII/RTU

ISOLATION
Approvals: UL, cUL, CE
Power to Input/Output: 2300 Vac per 1 min test; 1500 Vac per 1 min test (low voltage/power option)
Power to Relays/SSR Outputs: 2300 Vac per 1 min test
Relays/SSR to Relay/SSR Outputs: 2300 Vac per 1 min test
RS232/RS485 to Inputs/Outputs: 500 Vac per 1 min test

 
Thermocouple Input TypeDescriptionRangeAccuracyProcessProcess Voltage±100 mV, ±1, ±10 Vdc0.03% FSProcessProcess CurrentScalable within 0 to 24 mA0.03% FSJIron-Constantan-210 to 1200°C (-346 to 2192°F)0.4°C (0.7°F)KChromel-Alumel-270 to -160°C (-454 to -256°F)
-160 to 1372°C (-256 to 2502°F)1.0°C (1.8°F)
0.4°C (0.7°F)TCopper-Constantan-270 to -190°C (-454 to -310°F)
-190 to 400°C (-310 to 752°F)1.0°C (1.8°F)
0.4°C (0.7°F)EChromel-Constantan-270 to -220°C (-454 to -364°F)
-220 to 1000°C (-364 to 1832°F)1.0°C (1.8°F)
0.4°C (0.7°F)RPt/13%Rh-Pt-50 to 40°C (-58 to 104°F)
40 to 1788°C (104 to 3250°F)1.0°C (1.8°F)
0.5°C (0.9°F)SPt/10%Rh-Pt-50 to 100°C (-58 to 212°F)
100 to 1768°C (212 to 3214°F)1.0°C (1.8°F)
0.5°C (0.9°F)B30%Rh-Pt/6%Rh-Pt100 to 640°C (212 to 1184°F)
640 to 1820°C (1184 to 3308°F)1.0°C (1.8°F)
0.5°C (0.9°F)C5%Re-W/26%Re-W0 to 2320°C (32 to 4208°F)0.4°C (0.7°F)NNicrosil-Nisil-250 to -100°C (-418 to -148°F)
-100 to 1300°C (-148 to 2372°F)1.0°C (1.8°F)
0.4°C (0.7°F)RTDPt, 0.00385, 100 Ω, 500 Ω, 1000 Ω-200 to 850°C (-328 to 1562°F)0.3°C (0.7°F)RTDPt, 0.003916, 100 Ω-200 to 660°C (-328 to 1220°F)0.3°C (0.7°F)RTDPt, 0.00392, 100 Ω-200 to 660°C (-328 to 1220°F)0.3°C (0.7°F)Thermistor2252 Ω-40 to 120°C (-40 to 248°F)0.2°C (0.35°F)Thermistor5K Ω-30 to 140°C (-22 to 284°F)0.2°C (0.35°F)Thermistor10K Ω-20 to 150°C (-4 to 302°F)0.2°C (0.35°F)

Accessories
Use the optional PT-USB-CABLE for an IP65 rated panel mount USB connector. A 300 mm length cable connects from USB port of Platinum controller to your control panel. This accessory includes a protective end cap when not in use.

The PT-USB-ADAPTER, which is supplied with each unit, can be plugged into the controller and be used with a standard USB 2.0 memory stick.

This 1 GB USB thumbdrive has a standard USB connector on one end and a micro-USB connector on the other end. It is convenient for transferring files between your PC and your PLATINUM unit.
Optional PT-USB-CABLE Optional 1 GB USB thumbdrive
The part numbers listed below are only examples. Many more configurations are offered and can be constructed using the part number builder at the bottom of this page.

 

loading all models
loading all reviews
Rated 3 out of 5 by from Terrible website and stock Product is okay, website and delivery is horrible!
Date published: 2023-12-23
Rated 5 out of 5 by from Omega PID controller The PID controller we bought from omega was able to fix our temperature controller which we were struggling for about a month. Would definitely recommend it to other users.
Date published: 2023-12-06
Rated 4 out of 5 by from temp controlser included manual does not provide proper info for programing controller. downloading manual has much needed info.
Date published: 2023-03-19
Rated 5 out of 5 by from Solid Bright Display Works great in our Dyno, bright and visible among other instrumentation
Date published: 2022-01-16
Rated 2 out of 5 by from Support support support... We have bought a few of them to control temperature in vacuum chambers. All for ATE systems, meaning they need to be remotely controlled by a computer. The documentation with these PID is ridiculously inadequate, and I am being nice! We spent all our time trying to configure, control, configure, control... etc. The technical support is practically non existent. These are not new products. I would have assumed Omega would invest a little in all those years, just a little, to make working with them easier. Be aware that if you want to use these PID, you need to put aside a very long time just to understand how they work, as the manuals are useless in most cases.
Date published: 2021-08-18
Rated 3 out of 5 by from Good Very easy to setup and get working. Does a great job with the heat treat oven it is being used on. Unfortunately the USB board connection poped off the unit when i tried to insert the micro usb cable, so I can no longer use it in conjunction with my PC for data logging setup etc (maybe i don't know my own strength or maybe it was a bad solder connection not sure, it was a clean break on the soldier joint though). First time this has ever happened to me on any deice I have ever owned so it goes down a few stars for loosing so much functionality within the first week of ownership. Otherwise great unit.
Date published: 2020-04-10
Rated 4 out of 5 by from Good Product I bought this last week and its feature are amazing
Date published: 2019-04-01
Rated 5 out of 5 by from Love it, except one annoying little thing . . . Replaced a CNiS32 (where 4-button programming was driving me crazy) with a CN32Pt. Got it working OnOff (all I need for now) using Platinum Configurator 1.5.2.0 software in a few hours; BIG improvement over the buttons ! Using a PX309-300AV P-transducer, set scaling to give 20.7 bar at 100mV, set-point 11.0 bar. Great so far. However, cannot set deadband value smaller than 0.1; would prefer 0.05. Any way around this ? Maybe software update ?
Date published: 2018-07-11
Rated 5 out of 5 by from Excellent instruments ! We are laboratory of scientific institute and we already purchased 4 Omega Platinum controllers currently working perfectly in 4 new scientific instruments built in our lab giving millions of measurement cycles. We are going now a bit further into development and we need some more purely technical information, for instance can auto-tune be initiated over RS-232 serial protocol (which I currently could not figure out from serial protocol manual and I find command for same thing in modbus manual) and few similar questions. If we want, can we contact someone for such info ? Thank you and good job making instruments. Thomas
Date published: 2018-07-06
Rated 4 out of 5 by from Great features in controller, lousy documentation Purchased controller to receive 0-10V input and 0-10 Analog output. Set up documentation is very lacking. Controller now works very well, but we lost weeks trying to sort out the issues.
Date published: 2016-12-09
  • y_2024, m_3, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_18
  • loc_en_CA, sid_CN32PT-330, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
loading all QA

I have a CN8PTD-305, when I run a profile it will only run the first ramp/soak segment and will not advance to the next segment even with segments set to above 1. The tracking action doesn't affect this behaviour. How do I fix this?versions: FW1406,CS1520

Asked by: NickatBAA
Thank you for the inquiry. Please forward this request to TEMP@DWYEROMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-01-16

What is the specifications for a USB thumb drive? I'm trying 2-16GB and I did format one to FAT and the unit will not recognize (getting a red F100 error that requires a power cycle). If the drive is missing or unformatted, I get normal error messages.

Asked by: Gerald
Hi Gerald, Please try FAT32. If you still receive error message contact our temperature technical support. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-10-24

I have a new CN8DPT-220 my computer dose not see it when I plug it in with a usb cable (phone charging cable) why not? I have never been able to make this controller work The plug is sensitive in the side of And its very frustrating

Asked by: Onedusty
Thank you for your inquiry. It can be one of two things. It could be your PC Firewall blocking communication or the USB Cable quality issue. Try using a different PC/Cable.
Answered by: Application Engineer CB
Date published: 2021-09-01

Does the excitation current introduced by a CN32PT change depending on the installed probe's nominal resistance? (eg would a 100 ohm RTD have a different excitation current than a 1000 ohm RTD or a 2252 ohm thermistor)

Asked by: benjfitz
The excitation Voltages are all Controlled by the processor's program and will vary dependent on the type of input selected.
Answered by: ApplicationsEngineerANB
Date published: 2022-05-16

What is the range of Heating Control Cycle Settings? We need a controller with a faster relay switching time than the CND3, 5 seconds. It is not specified on the webpage or in the manual what the minimum setting for the Heating Control Cycle is. 1sec?

Asked by: jpvance
Hi JPVance, Thank you for the inquiry. Fastest cycle time is 0.1 sec. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-12-16

I have CN32PT-440-C24 units controlled by Modbus. I want to set a manual output level. On the front panel I can go to oPER > MANL > M.CNt, but can this be done over Modbus/serial communication? If so, what registers? The manual doesn't say.

Asked by: melectron
Hi melectron, Thank you for the inquiry. Please forward this question to temp@omega.com. https://assets.omega.com/manuals/M5458.pdf Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-03-18

I am switching from a cni series to a cn32pt series. Does the cn32pt provide the ramp-to-setpoint feature of the cni series by using a singular ramp then setting the end action to hold?

Asked by: Bob2727Bob
Thank you for your inquiry. It does contain all of these features and more.
Answered by: Application Engineer CB
Date published: 2023-12-07

Using a CN8DPT-305 to measure a 4-20 mA signal from a pressure transmitter and control a fan motor with a 0-10 VDC. I'd like to use the tare command to zero my display as process starts. When I use the tare command it sets it to random numbers - not zero.

Asked by: Kenneth
Kenneth, sorry to hear that the tare function does not work. After scaling the meter if you hit the left arrow button, you must see "TARE" and wen you enter the "ENTER" button the reading must display zero. If that does not work kindly call us at 1800 622 2378, we can troubleshoot with you and help you resolve this issue.
Answered by: SAE DV
Date published: 2021-06-14

How are DIN controllers mounted to front panels? Is there a bracket to secure the controller in place? I can't see the attachment in your cutout panels (e.g., https://www.omega.com/en-us/accessories/protection/electrical-enclosures/p/OM-HFPU).

Asked by: PLS34
Thank you for your inquiry. PLS34. All of our controllers come with mounting brackets and instructions on how to attach to a panel.
Answered by: Application Engineer MC
Date published: 2023-10-14

I recently purchased a Platinum Series DP8PT-330-006-C24-EIP universal controller. The manual doesn't have the communications information in it. Where can I find the information on the Modbus RTU ethernet communications for SCADA connection?

Asked by: MTen
Hi Marek, Thank you for the inquiry. Following links are for the manuals describing communications; https://assets.omega.com/manuals/M5458.pdf https://assets.omega.com/manuals/M5452.pdf And for the configurator software; https://assets.omega.com/manuals/M5461.pdf Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2020-12-18

What is the mechanical relays fastest switching time?

Asked by: jpvance
Thank you for your inquiry. One second (Seven seconds is recommended).
Answered by: Application Engineer CB
Date published: 2021-12-08

When I am trying to do a firmware upgrade I get E07. What do you suggest?

Asked by: Clemens
There is a E007 error which is an Auto-tune timeout error. Make sure auto-tune is not initiated when doing the firmware update and if still an issue contact the temperature group at temp@omega.com.
Answered by: ApplicationsEngineerANB
Date published: 2021-11-30

Hello, for SSR output control, it only has the VAC option, and if I plan to use the SSRDIN280DC10 relay, can I connect it to the Mechanical Relay control? Thanks.

Asked by: AnnaH
Thank you for your inquiry. You can only connect DC Controlled Solid State Relays to a DC Pulse Output Control Option only.
Answered by: Application Engineer CB
Date published: 2023-07-17

Is the CN16DPT-330-C24 the correct replacement for the CN77533-A2-2.8?

Asked by: RoHa
Thank you for inquiry. CN16DPT-330 is the best replacement.
Answered by: CB Engineer
Date published: 2021-02-15

We have issues with CN8DPT-305-C24 connected to 3-wire RTD. It seems like controller doesn't compensate for the wire resistance and the temperature reading is higher than it supposed to be. Look like this is controller issue. Is the recent firmware 1.04?

Asked by: myevit
Hi Myevit, Thank you for the inquiry. 1.04.06 is latest firmware. It shows on the controller display screen as 1.04. For questions on the 3 wire mode RTD please forward request to TEMP@OMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-11-09

I need a controller to handle two SSRs, with a degrees/minute programmable temperature ramp rate, RS-232 communication to understand a visual basic macro from MSExcel.

Asked by: Polymer John
Hi Polymer John, Thank you for the inquiry.This controller does not have ramp/rate function. You'll need to use a target temp and calculate time to target to achieve the ramp/rate. We do not have drivers to work with Windows Excel. Our free software may cover your requirements. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-05-24

What is the equation that calculates the temperature from mV

Asked by: ealmorgan
Hi, if you are using a thermocouple then here are some reference pages on how this is done. This all goes into detail on the Seebeck voltage. Please contact us if you need anything further. Thanks! https://www.omega.co.uk/prodinfo/thermocouples.html https://www.omega.co.uk/techref/
Answered by: Jane
Date published: 2019-05-15

Why does my new CN32PT-224-C24-DC initially display a TC temperature on the Platinum Monitor software, then flashes "oPEN" as soon as I start a run? The TC is fine and works on an older CN32PT controller I bought 3 years ago.

Asked by: JackTA
Hi JackTA Thank you for the inquiry. You might try a jumper wire in place of the TC. The instrument should see this as room temperature if it is set for TC input. If you have more questions please forward to TEMP@OMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-02-21

Could you suggest a model of Platinum Series Versatile High Performance PID Controllers with which we could set up linearization values with RTD ? We are using the CN32PT-444-C24-DC model right now but can't use the linearization process with RTD.

Asked by: Line
Hi Line, We have 1 or 2 point calibration under "t.cal" in manual. Please refer to section 6.8 of the manual. https://assets.omega.com/manuals/M5451.pdf Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2020-11-25

CN16DPT-145. There is limited info on the retransmit function. I'd like to retransmit measured temperature from a thermocouple. How does the scaling work for retransmit?

Asked by: NIST
To set the Analog output range on the Platinum Controllers you need to select the RNGE in the PROG menu then scale it in the RtRN parameter in the PROG menu in your case for ANG1 as well. Please call the temperature department if you need detailed assistance.
Answered by: ApplicationsEngineerANB
Date published: 2022-03-10

When I turn the power on to the Omega USB Platinum Temperature controller, the Omega display reads "oPER". What does this mean?

Asked by: Richie_GDS
Thank you for your inquiry! The "oPER" text on the display stands for Operating Mode and is found in the Level 1 Menu. For more information on how to navigate through various menus, please see page 16 of the Platinum Series Controller User Guide Manual (M5451).
Answered by: Application Engineer CK
Date published: 2021-05-28

All the controller have 2 or 3 outputs, but we can only control one load at a time due to having only one input. Then what is the purpose of having three different or same outputs?

Asked by: Maxy
Hi Maria, Thank you for the inquiry. Second output is often used for cooling. It can also be used for second heater ( or other load) to act as back up to a primary heater. There is a second PID group and control offset to provide for these options. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-08-18

I had bought the Item# CN16DPT-224-C24. I didn't notice the output for SSR is AC power and bought the SSR with DC input. Could you recommond a AC input SSR for me? Thank you!

Asked by: Anonymous
Thank you for your inquiry! The SSRL series (https://www.omega.com/en-us/control-monitoring/relays/solid-state-relays/ssrl240-660/p/SSRL240AC10) are available with either an AC or DC control input
Answered by: Application Engineer JM
Date published: 2021-03-04

I have a CN32PT-304 but i forgot the password and now I cannot change initial parameters, What can I do to retore the password? or Is the controller lost?

Asked by: Anonymous
Thank you for the inquiry. Please try the password "5709". Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-02-04

Hi there, I am interested in the CN32PT-440. Are the isolated DC pulse outputs isolated from the AC power input or the sensor input or both? I am assuming isolated means the grounds are floating compared to each other?

Asked by: Madt
Hi Madt, Thank you for the inquiry. On this model the DC pulse output signals are isolated from the AC line not the input signal. Isolation spec is detailed in section 9.5 on the manual; https://assets.omega.com/manuals/M5451.pdf Best regards Omega
Answered by: NorwalkAE_RS
Date published: 2021-01-24

I want to but a controller for heating only from 100 to 500 degree Celsius. Which option is better for this? Output with Mechanical relay or Solid State Relay?

Asked by: Maxy
Hi Maxy- If maintaining temp for long duration is your end goal then SSR will be best. Not only will the control around the set point be more precise but SSR also has extended life cycle over mechanical relay. Be sure to check the specs of the heater on power required as solid state relays and mechanical relays outputs vary.
Answered by: ApplicationsEngineer_RD
Date published: 2022-08-23

I want to drive a 24Vdc 3port/2way solenoid air valve. What output option do I select? I see there is a DC power supply option will that be needed?

Asked by: JulieC
Hi Julie, Thank you for the inquiry. For your device the best option to use is the mechanical relay. You will need a power source suitable for your relay coil. The internal excitation is limited to 25 mA @ 24 VDC. Best regards Omega
Answered by: ANBENG
Date published: 2019-11-13

Hi, I installed a CN32PT-305-DC in an aluminium case and the thermocouple reading is very sensible to the internal controller’s temperature ans doesn’t represent the true temperature at the sensor. How can I fix this problem ? Thanks

Asked by: Sylvain
Hi Sylvain, Thank you for the inquiry. Suggest to ensure that you have thermocouple connectors and thermocouple extension wire inside the enclosure. Double check the thermocouple wire polarity inside the enclosure. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2021-08-16

How do I change the output on a CN32PT-224-C24 to analog 0-5VDC. The Platinum GUI seems to resisto me making the change is there some king of unlock that needs to be done?

Asked by: Mark Morin
Hi Mark, Thank you for the inquiry. Unfortunately this controller does not have analog output. Similar controller with analog output is CN32PT-145-C24 Best regards OMEGA
Answered by: AENorwalk
Date published: 2020-04-02

I'm looking at the CN32PT-145-C24. Need to put out around 2 amps from a DC power supply to a resistive load when a certain temperature low point, then cut off current at higher temp. Is this doable? It looks like it, but I'm new to PID controllers.

Asked by: davidm
Thank you for your inquiry. Yes with this controller that is possible. You will need to use an SSRDC150VDC12 Solid State Relay to switch the DC Signal. See link below. https://www.omega.com/en-us/control-and-monitoring-devices/relays/solid-state-relays/p/SSRDC150VDC12
Answered by: Engineer CB
Date published: 2020-08-15
  • y_2024, m_3, d_28, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_53
  • loc_en_CA, sid_CN32PT-330, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 48ms
  • QUESTIONS, PRODUCT
Accessories
Standard USB to Micro USB Adapter
C$20.55
0 In Stock
USB Micro to Standard Cable with Panel Mount Connector
C$41.60
1 In Stock
1 GB Double-Ended USB Stick (Male Micro and Male Standard)
C$42.32
283 In Stock
en-CA
en
Save Configuration