text.skipToContent text.skipToNavigation

NSF/ANSI Certified Turbine Flow Meters

Turbine Flow Meter, 0.026 to 0.65 GPM, Trogamid, 1/4" NPT, 3 Pin Mini DIN

C$92.00

Item# BV1000TRN025A

In stock

Lead Time ( If not in Stock): 5 weeks

Turbine Flow Meter, 0.026 to 0.65 GPM, Trogamid, 1/4" NPT, 3 Pin Mini DIN BV1000TRN025A BV1000TRN025A
  • Compact size
  • Measurement in any meter orientation
  • Operating pressure up to 362.50 psi (25 bar)
  • Temperature range of –4…212° F (–20…100° C)
  • Accuracy of ± 3%
  • Resolution up to 83,000 ppg (22,000 ppl), depending on the model
  • NSF/ANSI Standards 61 and 372 Certified
  • K-Factor: See Product Data Sheet VIS-DS-00020-EN-12
5 Year Warranty

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Media Type
Flow Range
Accuracy
Output Signal
Max Process Temperature
Wetted Materials
Process Connection Type
Process Connection Size
Features
Connector Type


Product Specs

The Vision Turbine Meters comply with the lead-free provisions of the Safe Drinking Water Act. Available models include meters that are:

  • Bisphenol A (BPA)-free
  • Certified to NSF/ANSI Standards 61 and 372

  • MEASURING PRINCIPLE

    The rotor is turned by the liquid force proportional to flow. A Hall effect sensor supplies pulses that can be used for digital or analog signal processing. The generated pulses are specified as a K-factor.

    OPERATING PRINCIPLE

    Liquid flow causes a bladed turbine inside the meter housing to turn at an angular velocity directly proportional to the velocity of the liquid measured. As the blades pass beneath a magnetic pickup coil, a frequency signal is generated. Each pulse is equivalent to a discrete volume of liquid. The frequency pulse is directly proportional to the turbine angular velocity and the flow rate. The large number of pulses provides high resolution. As the mass of the turbine is small, the response time is fast. It is not necessary to install a straight length of pipeline upstream of the meter. The simple mechanical construction of the Vision meter provides a long lifespan without any loss of accuracy. Pressure spikes less than the burst pressure rating do not affect the measurements.

    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • LOCAL, getReviews, 0ms
    • REVIEWS, PRODUCT
    • bvseo-msg: The resource to the URL or file is currently unavailable.;
    • bvseo_sdk, java_sdk, bvseo-4.0.0
    • LOCAL, getContent, 0ms
    • QUESTIONS, PRODUCT
    • bvseo-msg: The resource to the URL or file is currently unavailable.;

    en-CA
    en
    Save Configuration