Single Point Load Cell with IP65 Rating
600 gf, ±0.028 %, Linearity, 1 mV/V Output, Cable
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | C$193.00 |
5-9 | C$183.35 |
10-24 | C$179.49 |
25-49 | C$171.77 |
50-99 | C$167.91 |
100+ | C$164.05 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- Aluminum-Alloy IP65 Single Point Load Cell.
- Colorless Anodized Aluminum
- Suitable for Pricing Scales, Bench Scales, etc.
- Available in Ranges from 600g to 200kg
LC61SP-600G Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Weight Capacity
Measurement Units
Linearity
Electrical Output (nominal)
Height
Width
Length
Force direction
Connection Type
Cable Length
Omega’s LC60 Series is a low cost, highly accurate, single point load cell, ideal for OEM applications such as electronic scales and weighing machines. The single point design is highly resistant to eccentric loading, allowing direct mounting to the scale base and weighing platform. The LC60 Series features a moisture-proof sealant and is available in ranges from 600 grams to 200 kilograms.
Maximum Platform Size:
LC61SP: 200 x 200 mm (7.87 x 7.87") LC62SP: 250 x 350 mm (9.84 x 13.77") LC63SP: 400 x 400 mm (15.74 x 15.74")
Specifications
LC62 and LC63: C3
OIML R60 Accuracy Class: LC61: C3D
Output Sensitivity (= FS, mV/V):
LC61: 1.0 ±0.1
LC62 and LC63: 2.0 ±0.2
Maximum Number of Load Cell Intervals(nLC):
LC61: 2500
LC62 and LC63: 3000
Ratio of Minimum LC Verification Interval Y = Emax/vmin:
LC61: 5000
LC62 and LC63: 10000
Combined Error:
LC61: ±0.028 %FS
LC62 and LC63: ±0.02 %FS
Minimum Dead Load: 0% FS
Safe Overload: 120% FS
Maximum Overload: 150% FS
Zero Balance: ±2.0% FS
Excitation, Recommended Voltage: 5 to 12 VDC
Excitation Maximum: 18(VDC)
Input Resistance ?: 406 ±6
Output Resistance ?: 350 ±3
Insulation Resistance M?: ? 5000 (50 VDC)
Compensated Temperature: -10 to 40ºC (14 to 104ºF)
Operating Temperature: -35 to 65ºC (-31 to 149ºF)
Storage Temperature: -40 to 70ºC (-40 to 158ºF)
Element Material: Aluminum
Recommended Bolt Size/Torque (Nm):
LC61: M3/1.5
LC62: M6/6 for < 30kg, M6/10 for > 30kg
LC63: M6/10
Ingress Protection (According to EN 60529): IP65
Figure 1 All Dimensions mm
Figure 2
Figure 3
Wiring

Maximum Platform Size:
Specifications
LC62 and LC63: C3
OIML R60 Accuracy Class: LC61: C3D
Output Sensitivity (= FS, mV/V):
LC61: 1.0 ±0.1
LC62 and LC63: 2.0 ±0.2
Maximum Number of Load Cell Intervals(nLC):
LC61: 2500
LC62 and LC63: 3000
Ratio of Minimum LC Verification Interval Y = Emax/vmin:
LC61: 5000
LC62 and LC63: 10000
Combined Error:
LC61: ±0.028 %FS
LC62 and LC63: ±0.02 %FS
Minimum Dead Load: 0% FS
Safe Overload: 120% FS
Maximum Overload: 150% FS
Zero Balance: ±2.0% FS
Excitation, Recommended Voltage: 5 to 12 VDC
Excitation Maximum: 18(VDC)
Input Resistance ?: 406 ±6
Output Resistance ?: 350 ±3
Insulation Resistance M?: ? 5000 (50 VDC)
Compensated Temperature: -10 to 40ºC (14 to 104ºF)
Operating Temperature: -35 to 65ºC (-31 to 149ºF)
Storage Temperature: -40 to 70ºC (-40 to 158ºF)
Element Material: Aluminum
Recommended Bolt Size/Torque (Nm):
LC61: M3/1.5
LC62: M6/6 for < 30kg, M6/10 for > 30kg
LC63: M6/10
Ingress Protection (According to EN 60529): IP65
Figure 1 All Dimensions mm

Figure 2

Figure 3

Wiring




What is the maximum strain for the LC61SP-2kg?
The maximum calibrated load range is 0 to 2 kilograms. In case of occasional accidental overload the load cell can handle up to 120% of it's calibrated load range.
Date published: 2020-08-22
On aluminum load cells ,LC61SP-3KG. Are connection wires included? What is recommended the supply voltage? Is there a transfer function that can be used to convert Vout measurement to mass? What is the sensitivity? Thanks Victor
Thank you for your question?
Output is a linear response over the sensors 0 to 3KG load range. Sensitivity of the LC61 is 1.0mV/V, +/- 0.1. A 0.45 meter long is attached to the unit. Wiring code= Red (+Exc), Black (-Exc), Green(+ Signal), White (- Signal). Maximum Excitation 18VDC.
Date published: 2019-07-05