Metric, Low Profile, Tension & Compression Load Cells
250 kgf, ±0.1%, Linearity, 3 mV/V Output, Cable
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | C$1,275.00 |
5-9 | C$1,211.25 |
10-24 | C$1,185.75 |
25-49 | C$1,134.75 |
50-99 | C$1,109.25 |
100+ | C$1,083.75 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- All Stainless Steel for Harsh Industrial Applications
- 5-Point NIST Traceable Calibration with 59 KOhm Shunt Cal Data Provided
- 0.25% Interchangeable for Multiple Load Cell Applications
- Rugged Industrail Design
- Easy to Use Twist Lock Connection
LCM402-250 Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Weight Capacity
OD
Through hole (ID)/ Threaded hole dimension
Height
Connection Type
Cable Length
Measurement Units
Force direction
Linearity
Electrical Output (nominal)
The LCM402 and LCM412 are also available in standard configurations, with 0-50 to 0-750,000 lb ranges and standard threads. Please see the LC402 for complete details, or contact our Pressure department for more information..
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 3 mV/V ±0.25%
5-Point Calibration: 0%, 50%, 100%, 50%, 0% in compression
Linearity: 0.10% FSO
Hysteresis: 0.10% FSO
Repeatability: 0.05% FSO
Zero Balance: ±1% FSO
Operating Temp Range:
LC402: -54 to 107°C (-65 to 225°F)
LC412: -54 to 127°C (-65 to 260°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.0025% FSO/°F
Span: 0.0025% FSO/°F
Safe Overload: 150% of Capacity
Ultimate Overload:
ranges ?400,000 lb: 300% of Capacity
ranges >400,000 lb: 200% of Capacity
Bridge Resistance: 350 ±10 ?
FS Deflection: 0.025 to 0.075 mm (0.001 to .003") typical
Construction: 17-4 PH Stainless Steel
Electrical Connection:
LC402/LCM402: 15 ft (4.8 m) 4-conductor shielded PVC cable
LC412/LCM412: DT02H-10-6P connect (or equivalent)
Mating Connector: PT06F10-6S, sold separately
SPECIFICATIONS
Excitation: 10 Vdc (15 Vdc max)
Output: 3 mV/V ±0.25%
5-Point Calibration: 0%, 50%, 100%, 50%, 0% in compression
Linearity: 0.10% FSO
Hysteresis: 0.10% FSO
Repeatability: 0.05% FSO
Zero Balance: ±1% FSO
Operating Temp Range:
LC402: -54 to 107°C (-65 to 225°F)
LC412: -54 to 127°C (-65 to 260°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.0025% FSO/°F
Span: 0.0025% FSO/°F
Safe Overload: 150% of Capacity
Ultimate Overload:
ranges ?400,000 lb: 300% of Capacity
ranges >400,000 lb: 200% of Capacity
Bridge Resistance: 350 ±10 ?
FS Deflection: 0.025 to 0.075 mm (0.001 to .003") typical
Construction: 17-4 PH Stainless Steel
Electrical Connection:
LC402/LCM402: 15 ft (4.8 m) 4-conductor shielded PVC cable
LC412/LCM412: DT02H-10-6P connect (or equivalent)
Mating Connector: PT06F10-6S, sold separately



Can load be applied over the entire face of the load cell or is there a certain area on the face that must receive load?
Thank you for your inquiry.
That load cell should be loaded only on the inner raised lip or with a load button installed
Hope this was helpful?
Date published: 2019-11-15
Does this load cell measure Fx, Fy, Fz, Mx, My, Mz or does it only measure one value?
Hi, thanks for contacting Omega. This is a single output load cell, only providing tension or compression signals perpendicular to the planner faces. Please contact our Tech Support if you need any further assistance.
Date published: 2019-01-29
Accessories