Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type | Maximum Operating Temperature | Minimum Operating Temperature | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
1" NPT
|
6 5⁄16"
|
0.75 kW
|
64 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
187°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
1" NPT
|
6 5⁄16"
|
0.75 kW
|
64 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
187°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
1" NPT
|
6 5⁄16"
|
1.0 kW
|
85 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
187°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
1" NPT
|
6 5⁄16"
|
1.0 kW
|
85 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
187°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
1" NPT
|
8 1⁄16"
|
1.25 kW
|
83 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
187°F
|
60°F
|
Integral Thermostat
|
Immersion heater with copper sheath element, 1.25" NPT screw plug fitting and designed for clean water applications. Explosion resistant options available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type |
---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
4 1/4" NPT
|
6 1⁄8"
|
1.0 kW
|
86 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
5 1/4" NPT
|
6 1⁄8"
|
1.0 kW
|
86 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
9 1/4" NPT
|
6 1⁄8"
|
1.2 kW
|
53 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
10 1/4" NPT
|
6 1⁄8"
|
1.2 kW
|
53 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
12 1/4" NPT
|
6 1⁄8"
|
1.5 kW
|
65 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
Immersion heater with incoloy sheath elements, 2.5" NPT fitting, designed for use in oil and clean water, up to 40 kW of power and integrated J type thermocouple.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type | Maximum Operating Temperature | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2 1/2" NPT
|
20 3⁄16"
|
Oil 15 kW Water 15 kW, 59 kW
|
Oil 15 W/in2 Water 15 W/in2, 59 W/in2
|
120V/240V
|
1 Phase, 3 Phase
|
Oil, Water
|
Incoloy
|
General Purpose NEMA-1 rated
|
300°F
|
Integral Tupe J Thermocouple
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
20 3⁄16"
|
Oil 15 kW, 5 kW Water 15 kW, 5 kW, 59 kW
|
Oil 15 W/in2, 5 W/in2 Water 15 W/in2, 59 W/in2, 5 W/in2
|
240V, 480V
|
1 Phase, 3 Phase
|
Oil, Water
|
Incoloy
|
General Purpose NEMA-1 rated
|
300°F
|
Integral Tupe J Thermocouple
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
30 3⁄8"
|
Oil 11 kW Water 11 kW, 80 kW
|
Oil 11 W/in2 Water 11 W/in2, 80 W/in2
|
120V, 208V, 240V
|
1 Phase, 3 Phase
|
Oil, Water
|
Incoloy
|
General Purpose NEMA-1 rated
|
300°F
|
Integral Tupe J Thermocouple
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
20 3⁄16"
|
Oil 20 kW Water 20 kW, 78 kW
|
Oil 20 W/in2, Water 20 W/in2, 78 W/in2
|
120V, 208V, 240V
|
1 Phase, 3 Phase
|
Oil, Water
|
Incoloy
|
General Purpose NEMA-1 rated
|
300°F
|
Integral Tupe J Thermocouple
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
20 3⁄16"
|
Oil 2 kW, 5 kW, 15 kW, 20 kW Water 2 kW, 5 kW, 15 kW, 20 kW, 78 kW
|
Oil 5 W/in2, 15 W/in2 Water 5 W/in2, 15 W/in2, 2 W/in2, 20 W/in2, 78 W/in2
|
120V, 208V, 240V, 480V
|
1 Phase, 3 Phase
|
Oil, Water
|
Incoloy
|
General Purpose NEMA-1 rated
|
300°F
|
Integral Tupe J Thermocouple
|
Immersion heater with incoloy sheath element, 2" NPT screw plug fitting and can be inserted into pipes. Explosion resistant enclosure options available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Sheath Material | Enclosure Type |
---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2" NPT
|
319"
|
11.5 kW
|
12.9 W/in2
|
480V
|
1 Phase
|
Incoloy
|
Moisture Resistant/Explosion Resistant Enclosure
|
|
Screw Plug Immersion
|
2" NPT
|
127"
|
4 kW
|
11.7 W/in2
|
240V
|
1 Phase
|
Incoloy
|
Moisture Resistant Terminal Enclosure
|
Immersion heater with copper sheath element, 2" NPT fitting and power range from 3 to 12 kW. Designed for clean water and explosion resistant enclosures available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type |
---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2" NPT
|
7"
|
3 kW
|
67 W/in2
|
240V
|
3 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
7"
|
3 kW
|
67 W/in2
|
480V
|
3 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
12"
|
6 kW
|
67 W/in2
|
240V
|
3 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
12"
|
6 kW
|
67 W/in2
|
480V
|
3 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
17 1⁄2"
|
9 kW
|
65 W/in2
|
240V
|
3 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
Immersion heater with incoloy or steel sheath element, 2.5" square flange mounted, designed for water and air applications and up to 5 kW or power.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type | Flange |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Flanged Immersion
|
2 1/2" Square
|
12 5⁄16"
|
3 kW
|
70 W/in2
|
240V
|
3 Phase
|
Water
|
Incoloy
|
Electrical Enclosure
|
2 1⁄2" Square Steel
|
|
Flanged Immersion
|
2 1/2" Square
|
19"
|
5.0 kW
|
70 W/in2
|
120V
|
3 Phase
|
Water
|
Incoloy
|
Electrical Enclosure
|
2 1⁄2" Square Steel
|
|
Flanged Immersion
|
2 1/2" Square
|
11"
|
1.25 kW
|
70 W/in2
|
208V
|
3 Phase
|
Water
|
Incoloy
|
Electrical Enclosure
|
2 1⁄2" Square Steel
|
|
Flanged Immersion
|
2 1/2" Square
|
7 3/8"
|
1.5 kW
|
70 W/in2
|
120V
|
3 Phase
|
Water
|
Incoloy
|
Electrical Enclosure
|
2 1/2" Square Steel
|
|
Flanged Immersion
|
2 1/2" Square
|
9"
|
2 kW
|
70 W/in2
|
240V
|
3 Phase
|
Water
|
Incoloy
|
Electrical Enclosure
|
2 1⁄2" Square Steel
|
Immersion heater with stainless steel sheath element, 2" NPT screw plug fitting and designed for medium weight oil. Enclosure NEMA-1 rated and explosion resistant options.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type |
---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2" NPT
|
24 7⁄8"
|
2 kW
|
15 W/in2
|
240V
|
1 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
24 7⁄8"
|
2 kW
|
15 W/in2
|
480V
|
1 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
32 3⁄4"
|
2.66 kW
|
15 W/in2
|
480V
|
1 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
40 1⁄4"
|
3.33 kW
|
15 W/in2
|
240V
|
1 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2" NPT
|
40 1⁄4"
|
3.33 kW
|
15 W/in2
|
480V
|
1 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
Immersion heaters with steel sheath element, 2.5" NPT screw fitting and integrated thermostat for medium weight oil applications. Explosion proof option available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type | Maximum Operating Temperature | Minimum Operating Temperature | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2 1/2" NPT
|
24 1⁄2"
|
3 kW
|
15 W/in2
|
240V
|
3 Phase
|
Medium Weight Oil
|
Steel
|
Moisture Resistant/Explosion Resistant Enclosure
|
550°F
|
200°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
24 1⁄2"
|
3 kW
|
15 W/in2
|
480V
|
3 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
100°F
|
0°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
24 1⁄2"
|
3 kW
|
15 W/in2
|
240V
|
3 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
24 1⁄2"
|
3 kW
|
15 W/in2
|
480V
|
3 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
32 3⁄8"
|
4 kW
|
15 W/in2
|
480V
|
3 Phase
|
Medium Weight Oil
|
Steel
|
General Purpose NEMA-1 rated
|
100°F
|
0°F
|
Integral Thermostat
|
Immersion heater with copper sheath element, 2.5" NPT screw plug fitting and designed for clean water applications. Explosion resistant options available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type |
---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2 1/2" NPT
|
11 7⁄8"
|
4.5 kW
|
48 W/in2
|
208V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
11 7⁄8"
|
4.5 kW
|
48 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
17 7⁄8"
|
6 kW
|
48 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
24 1⁄2"
|
9 kW
|
47 W/in2
|
208V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
24 1⁄2"
|
9 kW
|
47 W/in2
|
480V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
Immersion heaters with copper sheath element, 2.5" NPT screw fitting and integrated thermostat for clean water applications. Explosion proof options available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type | Maximum Operating Temperature | Minimum Operating Temperature | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2 1/2" NPT
|
7 3⁄8"
|
3 kW
|
51 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
7 3⁄8"
|
3 kW
|
51 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
11 3⁄8"
|
4.5 kW
|
48 W/in2
|
120V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
11 3⁄8"
|
4.5 kW
|
48 W/in2
|
208V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2 1/2" NPT
|
11 3⁄8"
|
4.5 kW
|
48 W/in2
|
240V
|
1 Phase
|
Clean Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
Immersion heater with stainless steel sheath element, 1.25" NPT screw plug fitting and designed for process water. Explosion resistant options available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type |
---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
1 1/4" NPT
|
6 1⁄8"
|
2 kW
|
86 W/in2
|
120V
|
1 Phase
|
Process Water
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
1 1/4" NPT
|
6 1⁄8"
|
2 kW
|
86 W/in2
|
240V
|
1 Phase
|
Process Water
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
1 1/4" NPT
|
6 1⁄8"
|
2 kW
|
86 W/in2
|
120V
|
1 Phase
|
Process Water
|
Stainless Steel
|
Moisture Resistant/Explosion Resistant Enclosure
|
|
Screw Plug Immersion
|
1 1/4" NPT
|
6 1⁄8"
|
1.0 kW
|
43 W/in2
|
120V
|
1 Phase
|
Process Water
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
|
Screw Plug Immersion
|
1 1/4" NPT
|
6 1⁄8"
|
1.0 kW
|
43 W/in2
|
120V
|
1 Phase
|
Process Water
|
Stainless Steel
|
Moisture Resistant/Explosion Resistant Enclosure
|
Immersion heaters with stainless steel sheath element, 2" NPT screw fitting and integrated thermostat for process water applications. Explosion proof option available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type | Maximum Operating Temperature | Minimum Operating Temperature | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2" NPT
|
9"
|
2 kW
|
47 W/in2
|
240V
|
1 Phase
|
Mild Acid or Alkaline
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
11 1⁄2"
|
3 kW
|
43 W/in2
|
208V
|
1 Phase
|
Mild Acid or Alkaline
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
11 1⁄2"
|
3 kW
|
43 W/in2
|
240V
|
1 Phase
|
Mild Acid or Alkaline
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
17 1⁄2"
|
4 kW
|
44 W/in2
|
208V
|
1 Phase
|
Mild Acid or Alkaline
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
17 1⁄2"
|
4 kW
|
44 W/in2
|
480V
|
1 Phase
|
Mild Acid or Alkaline
|
Stainless Steel
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
Immersion heaters with copper sheath element, 2" NPT screw fitting and integrated thermostat for clean water applications. Explosion proof options available.
Product Number | Form Factor | Connection Type | Heating Element Length | Power | Power Density | Supply Voltage | Supply Voltage Type | Heated Medium | Sheath Material | Enclosure Type | Maximum Operating Temperature | Minimum Operating Temperature | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Screw Plug Immersion
|
2" NPT
|
40 1/2"
|
10 kW
|
46 W/in2
|
240V
|
1 Phase
|
Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
40 1/2"
|
10 kW
|
46 W/in2
|
480V
|
1 Phase
|
Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
48"
|
12 kW
|
46 W/in2
|
240V
|
1 Phase
|
Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
12"
|
1.5 kW
|
48 W/in2
|
120V
|
1 Phase
|
Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|
|
Screw Plug Immersion
|
2" NPT
|
12"
|
1.5 kW
|
48 W/in2
|
240V
|
1 Phase
|
Water
|
Copper
|
General Purpose NEMA-1 rated
|
250°F
|
60°F
|
Integral Thermostat
|