All Products
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
- Sign In
- Register
- Resources
- Services
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
-
ContactHelpTechnical Reference1-888-826-6342 | 1-203-359-1660 (US & Canada)
- Sign In
- Register
- Home
- Process Switches
- Flow Switches
- Thermal Dispersion Flow Switches for Liquids
Thermal Dispersion Flow Switches for Liquids
C$290.00
Item# FST-211-SPST

Quantity | Price each |
---|---|
1-9 | C$290.00 |
10-24 | C$275.50 |
25-49 | C$269.70 |
50-99 | C$258.10 |
100-199 | C$252.30 |
200+ | C$246.50 |
Please add to cart to keep it or exit the configuration
In stock
Thermal Dispersion Flow Switches for Liquids FST-211-SPST FST-211-SPST
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getAggregateRating, 170ms
- REVIEWS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
- High Reliability — No Moving Parts
- Very Low Flow Detection–Down to 0.04 FPS Liquids
- Use in 1/8 through 12" Pipe or Tubing
- SPST Relay Standard
- Excellent for Pump and Valve Monitoring of Critical Flows
Product info
Product Specs
- Maximum Pressure PP or PVDF: 150 psi @ 25°C (77°F) derated @ 1.667 psi per °C above 25°C (77°F)
- Minimum Supply Voltage 12 VDC
- Switch Operation selectable
OMEGA™ FST-200 Series flow switches use thermal dispersion technology to create a very accurate and economical method of sensing flow. Monitor fluids from 0.4 to 1.2 specific gravity, 1 to 300 cp, and pulsating flow from 10 to 100 pulses per minute. The sensors incorporate two temperature probes, one of which is heated. The flow of liquid reduces the temperature of the heated probe, decreasing the temperature differential with the non-heated probe. OMEGA’s LVCN-131 and LVCN-141 of controllers can easily be interfaced to perform a variety of control functions.
SPECIFICATIONS
Range: 0.04 to 3 fps (liquids)
Accuracy: ±5% of setpoint at constant temperature and flowrate
Response time: 10 seconds after initial 30 sec warm up
Setpoint Drift with Fluid Temperature: 0.5% per °C
Voltage Input: 12-36 Vdc@70 mA
Contact Output Mode: selectable, NO or NC states
Fluid Temperature: 0 to 60°C (32 to 140°F)
Max Fluid Pressure (PP or PVDF): 150 psi @ 25°C (77°F)
derated @1.667 psi per °C above 25°C (77°F)
Wetted Materials: PP and PVDF
Cable Specifications: 3 m (10 ft)
Max Cable Length: 305 m (1000 ft)
Dimensions: 76.2 or 114.3 x 26.7 mm dia. (3.0 or 4.5 x 1.05')
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getReviews, 19ms
- REVIEWS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getContent, 136ms
- QUESTIONS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
Request an RoHS Status