Mass Flowmeters and Controllers With Or Without Integral Display

Item# FMA-A2100

Mass Flowmeters and Controllers With Or Without Integral Display Mass Flowmeters and Controllers With Or Without Integral Display

Description

The FMA-A2100/2200/2300/2400 Series Electronic Mass Flowmeters/ Controllers provide high performance, versatility and state-of-the-art design in one compact package. The FMA-A2100/ 2200/2300/2400 uses capillary-type thermal technology to directly measure mass flow of gases. No temperature, pressure, or square root corrections are required. The FMA-A2300/2400 Series comes with an LCD display, and all models come with linear 0-5 and 4-20 mA output.

The FMA-A2100/2200/2300/2400 measures the mass flowrate of gases in 24 ranges from 0-10 SCCM to 0-100 SLM. For the complete listing, refer to the range table below. The FMA-A2100/2200/ 2300/2400 Series is compatible with most noncorrosive gases. The user is advised to check the wetted materials against gas compatibility.

OMEGA’s Mass Flow Controllers use an internal electromagnetic proportional valve to control the mass flowrate. A command signal can be supplied either by the internal setpoint pot or by a 0-5 Vdc external source.
FMA-A2100
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 1500ms
  • REVIEWS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 1,500ms;
  • ±1% Accuracy
  • Linear Output
  • Low Cost
  • Thermal Technology
  • For Flow Rates up to 75 SLM
  • Power Supply Included
  • Comes standard with 5-point NIST cert
com.omegaengineering.b2bfacades.product.data.CalibrationCertificatesData@3f2bf2bb
com.omegaengineering.b2bfacades.product.data.CalibrationCertificatesData@717c2ced
Accuracy Value
Additional Option
Display Type
Flange Type
Flow Measuring Range
Housing Material
Media Type
Output Signal
Power Source
Retransmission/Analog Output
See All Options
Quantity Price each
1-4 C$865.00
5-9 C$821.75
10-10 C$804.45
11-24 C$790.50
25-49 C$769.85
50-99 C$752.55
100+ C$735.25

0 In Stock

Lead Time: 5 weeks

Product Specs

  • Accuracy Value ±1% of full scale including linearity
  • Connection Type 1/4 FNPT standard
  • Maximum Ambient Temperature 1/4 FNPT standard
  • Maximum Burst Pressure ±0.15% full scale or better
  • Maximum Operating Pressure 100:1
  • Measurement Units 50 {C} (122 {F})
  • Minimum Ambient Humidity 0.05% full scale per 1°C or better
  • Measurement Type Flow
  • Minimum Ambient Temperature 0 {C} (32 {F})
  • Minimum Pressure 5 seconds
  • Pressure Coeffcient 0.01% full scale per psi or better
  • Pulse Output Linear 0 to 5 Vdc
  • Response Time 5 seconds
  • Supply Voltage Meters: 24 Vdc @ 150 mA
  • Temperature Coefficient 0.05% full scale per 1°C or better
  • Wetted Materials Standard: Polyacetal
  • Turndown Ratio 100:1

Description

The FMA-A2100/2200/2300/2400 Series Electronic Mass Flowmeters/ Controllers provide high performance, versatility and state-of-the-art design in one compact package. The FMA-A2100/ 2200/2300/2400 uses capillary-type thermal technology to directly measure mass flow of gases. No temperature, pressure, or square root corrections are required. The FMA-A2300/2400 Series comes with an LCD display, and all models come with linear 0-5 and 4-20 mA output.

The FMA-A2100/2200/2300/2400 measures the mass flowrate of gases in 24 ranges from 0-10 SCCM to 0-100 SLM. For the complete listing, refer to the range table below. The FMA-A2100/2200/ 2300/2400 Series is compatible with most noncorrosive gases. The user is advised to check the wetted materials against gas compatibility.

OMEGA’s Mass Flow Controllers use an internal electromagnetic proportional valve to control the mass flowrate. A command signal can be supplied either by the internal setpoint pot or by a 0-5 Vdc external source.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 1502ms
  • REVIEWS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 1,500ms;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 1500ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 1,500ms;