Self-Adhesive Polyimide Fast Response Surface Thermocouples

Surface Thermocouple with Self-Adhesive Backing - Package of 5

C$190.24

Item# SA1-K-SRTC

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-9 C$190.24
10-24 C$180.73
25-99 C$171.22
100-499 C$161.70
500-999 C$152.19
1000+ C$142.68

In stock

Lead Time (If not in stock): 4 weeks
Surface Thermocouple with Self-Adhesive Backing - Package of 5 SA1-K-SRTC SA1-K-SRTC
  • Patented Spool Caddy
  • Self Adhesive Backing for Easy Installation
  • Better Than 0.3 Second Response Time
  • 1 m (36') or 2 m (72') Color-Coded PFA Insulated Leads

SA1-K-SRTC Model Options

View all models

Edit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination or click the CONFIGURE button to build your own.

Thermocouple Type
Process Temperature Range
Termination Connection Type
Cable Length
Features
Category
Sensor Application
Cable Insulation
Color Code Standard
Mounting Style
Probe Diameter


OMEGA’s self-adhesive thermocouple temperature sensors have now been expanded to include the popular miniature connector with our patented spool caddy. The spool caddy provides a convenient way to store the thermocouple wire that is not needed for the application.



Specifications
Thermocouple Calibrations: J (Iron-Constantan), K (CHROMEGA™-ALOMEGA™), T (Copper Constantan), E (CHROMEGA™-Constantan)
Adhesive: Silicon based cement
Maximum Temperature: 175°C (350°F) continuous
Minimum Temperature: -60°C (-75°F) continuous
Dimensions: 25 L x 19 W x 0.3 mm (1 x 0.8 x 0.01")
Laminates: High temperature polymer, and fiberglass reinforced polymer layers
Wire: 30 AWG PFA-coated
Adhesive Pad (TAP): Polymide Film with a silicone pressure sensitive adhesive.
13% Polymide, 32% Polymethyl phenylsiloxane, 54% Saturated Paper

Model No.-ANSI Color Code Wire
Gage
Length
meter(in)
Insulation
Thermocouple with Stripped Leads Thermocouple with Spool Cap Connector Thermocouple with SMP connector and Strain Relief
SA1-J SA1-J-SC SA1-J-SRTC 30 1 (40) PFA
SA1-K SA1-K-SC SA1-K-SRTC 30 1 (40) PFA
SA1-T SA1-T-SC SA1-T-SRTC 30 1 (40) PFA
SA1-E SA1-E-SC SA1-E-SRTC 30 1 (40) PFA
SA1-J-72 SA1-J-72-SC SA1-J-72-SRTC 30 2 (80) PFA
SA1-K-72 SA1-K-72-SC SA1-K-72-SRTC 30 2 (80) PFA
SA1-T-72 SA1-T-72-SC SA1-T-72-SRTC 30 2 (80) PFA
SA1-E-72 SA1-E-72-SC SA1-E-72-SRTC 30 2 (80) PFA
Note: 2 m (80") is the longest length available with spool caddy.



NIST Traceable certification is available for this product - Consult Sales or Engineering

View the Thermocouple Accuracy and Color Code charts
loading all models
loading all reviews
Rated 5 out of 5 by from Thermocouple Ready for use, simple connectivity, durable product
Date published: 2022-08-08
Rated 5 out of 5 by from Great thermocouple I’ve been using this type of thermocouple throughout my career for engine and cooling applications for years. They work great and are very reliable.
Date published: 2022-01-29
Rated 4 out of 5 by from Well Made, Inexpensive Well made for something that can be disposable because it does not cost much.
Date published: 2021-03-26
Rated 5 out of 5 by from Small J Type Thermocouple I was looking for a very small, J type thermocouple that would fit flat against a glass surface without an air gap. This self adhesive thermocouple, model SA1-J-72 met all of my needs and I was very relieved that it has 72" leads which is a big plus.
Date published: 2021-03-04
Rated 1 out of 5 by from not very adhesive poor adhesion. would not stick to cleaned stainless steel pipe
Date published: 2020-12-02
Rated 5 out of 5 by from Sticky as Maple Syrup. When the surface is cleaned and prepped properly, these will stick to just about anything. Be careful contaminating them with your finger tips -- usually can only get one good use out of them before they lose their tackiness which is to be expected.
Date published: 2020-09-30
Rated 5 out of 5 by from Review of Surface Thermocouples Nice quality device. Each TC was individually wrapped. The connector end has a professional looking strain relief on it. The only thing that might be an issue (and it could be either a positive or a negative), is the connector itself is sealed. On the one hand, users can't get into it and mess up the connections. On the other hand, if something does go wrong with the connections inside the connector, it isn't easily repairable and may not be repairable at all requiring the replacement of the device.
Date published: 2020-09-30
Rated 5 out of 5 by from Great product! Great product! Too bad you’re website is garbage! Please go back to the old one! I can find anything!
Date published: 2020-07-02
Rated 5 out of 5 by from Very durable I bought many of these over the years. Even after adhesive wears off the last forever without breaking
Date published: 2019-03-30
Rated 5 out of 5 by from fantastic TC great product, gives me exactly what I want in a TC
Date published: 2019-03-20
Rated 5 out of 5 by from Works very good I used them to monitor battery temperature project and worked very well. The stick on tape works very well and was able to re use them several times.
Date published: 2019-03-13
  • y_2024, m_3, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_19
  • loc_en_CA, sid_SA1-K-SRTC, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
loading all QA

What is the accuracy of SA1-K thermocouples?

Asked by: EngTester
Thank you for your inquiry EngTester. The accuracy of SA1-K thermocouple is +/- 1.1°C or 0.4% whichever is greater.
Answered by: Application Engineer SP
Date published: 2022-06-22

Can this thermocouples work properly in a surface underwater?

Asked by: Neutrino
Thank you for your inquiry. This product is not suitable for water submersion.
Answered by: CB Engineer
Date published: 2020-10-05

Are these suitable for a Class 1, Div. 2 environment???

Asked by: Buysy
Thank you for your inquiry. This product is not rated for a Class I, Division 2 environment.
Answered by: Application Engineer JB
Date published: 2020-11-18

Whats the output signal? 4-20mA?

Asked by: mtalhaus
Thank you for your inquiry. The output of all thermocouples including the SA1 series is in mV
Answered by: Application Engineer MC
Date published: 2023-11-25

May I ask what is the transfer function (S-domain) of this sensor because I need to design a control system for certain application and I need the transfer function of this sensor.

Asked by: hakmi
Hi Hakmi, Thank you for the inquiry. We have not evaluated for this detail on response times. Testing has shown better than 0.3 seconds response time. Best regards, OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-01-02

I had one peel off of a metal surface, can an adhesive be applied to re-attach it? If so, which one?

Asked by: Moosa
Thank you for your inquiry Moosa. You could use the OB-200 epoxy as an adhesive up to a maximum temperature of 175 C. Using the epoxy will be a permanent fix. You can also use any general purpose adhesive to reattach the sensor as long as it doesn't exceed the maximum temperature of 175 C.
Answered by: Application Engineer SP
Date published: 2021-07-20

What is the dielectric withstand voltage (specifically, DC) of the PFA insulation on these wires?

Asked by: HVBatteryGuy
There is no dielectric rating on the insulation used on these Thermocouple probes. The dielectric constant for the PFA used is 2.1 per ASTM D50.
Answered by: ApplicationsEngineerANB
Date published: 2024-03-15

What material is the insulation?

Asked by: Hira
Thank you for connecting with Omega Engineering. The lead wire is PFA insulated on part number SA1-K-72-RoHS.
Answered by: Application Engineer RD
Date published: 2022-01-28

How do I convert the mV output to the respective temperature in degrees C?

Asked by: PierreLaplace
Thank you for your inquiry. You'll need a thermocouple meter. Please see this link to our temperature meters: https://www.omega.com/en-us/test-inspection/handheld-meters/c/temperature-and-humidity-and-dew-point-meters
Answered by: NorwalkAE_SP
Date published: 2024-03-01

What surface preparation should be performed for titanium mounting.

Asked by: Wilson405
Hi Wilson405, Thank you for the inquiry. Just need to ensure surface is clean of oils. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2024-03-19

looking for cost and spec sheet for a SA1-T adhesive mount

Asked by: obewan80
Thank you for your inquiry obewan80. Here is the link for the SA1-T: https://www.omega.com/en-us/temperature-measurement/temperature-surface-sensors/sa1/p/SA1-T. You can find the price and data sheet on this web page. If you have any other questions, please do not hesitate to contact us directly at 1-800-622-2378, ask for Temperature Engineering or temp@omega.com.
Answered by: Application Engineer MC
Date published: 2023-11-25
  • y_2024, m_3, d_28, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_19
  • loc_en_CA, sid_SA1-K-SRTC, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 38ms
  • QUESTIONS, PRODUCT
en-CA
en
Save Configuration