Skip to search Skip to main content Skip to navigation

Appelez-nous au 1-888-826-6342

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

DIN Rail Loop Powered RTD Input Signal Conditioner

DIN Rail Mount Loop-Powered RTD Input Signal Conditioner

C$205.03

Article# DRA-RTT-2

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$205.03
5-9 C$194.78
10-24 C$190.68
25-49 C$182.48
50-99 C$178.38
100+ C$174.28

En stock

Délai de livraison (si pas en stock): 7 semaines
DIN Rail Mount Loop-Powered RTD Input Signal Conditioner DRA-RTT-2 DRA-RTT-2
  • ±0.1% Accuracy
  • Linearized
  • Field Rangeable
  • Non-Isolated

DRA-RTT-2 Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Input Type
Input Class
Input Ranges
Output Type
Output Class
Supply Voltage Type
Isolation
Programability


Model DRA-RTT-2 is a non-isolated signal conditioner that accepts 100 Ohm Platinum RTD input and converts this into a 4-20 mA process current output which is linearly proportional to temperature. These signal conditioners incorporate excellent lead wire compensation and linearization circuitry. Field ranging is accomplished by using an internal DIP switch array for coarse range setting and front panel accessible multi-turn zero and span potentiometers for fine tuning. Test terminals are provided to monitor the transmitter’s 4-20 mA output without disturbing the actual process loop.
loading all models
loading all reviews
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
loading all QA

Can this DIN Rail Loop Powered RTD Input Signal Conditioner, convert PTC to 4-20 mA?

Asked by: Nadir
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Answered by: Application Engineer PV
Date published: 2021-07-28
  • y_2024, m_4, d_24, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_DRA-RTT-2, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 22ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration