fr
Enregistrer la configuration
text.skipToContent text.skipToNavigation
Configurer le produit
Configuration enregistrée
Voir la configuration
Termes et conditions

1/4 DIN 6-Zone Temperature Controllers with RS-232 Communications and Free Configuration Software

Article# CN616TC1

1/4 DIN 6-Zone Temperature Controllers with RS-232 Communications and Free Configuration Software 1/4 DIN 6-Zone Temperature Controllers with RS-232 Communications and Free Configuration Software

Description

The CN616 series has been discontinued. Please see the CN616A as a possible alternative or contact our Electronic Engineering department.

The CN616 Series is a highly versatile six-loop microprocessor-based controller designed for easy front panel or remote setup and operation. Each of six zones is sequentially scanned, and active zones are displayed. Individual zones can be locked for monitoring. Each instrument is programmable to meet operator needs for: Thermocouple Type, Temperature units Hi, Lo or Hi/Lo Alarm configured as Latching or Non-Latching and Autotune with Manual Trim or Manual PID Setting. The Zone Display Scan Time and Ramp/Soak can be set by the operator. Parameters and setpoints are retained when power is turned off. Password protection is provided to prevent accidental changes to calibration, PID setting and ramp/soak profile. If power loss occurs, the controller retains all the latest parameters and returns to “Run” mode.

All CN616 Series Controllers have RS-232 three-wire serial communications. Up to 10 units can be daisy-chained together. CN616-SOFT software is included with every unit at no charge. Windows 16/32 bit Operating Systems (Fully supported up to Windows XP)

Line Voltage is 120 Vac (110 vAC to 130 Vac)or 240 Vac (220 Vac to 260 Vac) selectable by external jumper assembly. Connections are made to the back of the instrument through easy-to-use screw terminal plugs.

The CN616 Series implements a security password to protect settings. The password can be enabled or disabled on the front panel and changed via RS-232. Calibration is performed on the front panel and is separately password protected. Higher level passwords are available.

The instrument is housed in a 1/4 DIN aluminum box which does not have to be removed for mounting. The unit mounts in a 1/4 DIN panel cutout and is secured by slide brackets. Control is done via 6 dc pulse outputs (one for each zone).

A single output relay is provided to indicate an alarm condition on any zone. The instrument shows an alarm condition by flashing the main temperature display while indicating the zone in alarm with a flashing zone number display. When set for Non-Latching, the alarm automatically resets when the condition changes. The alarm must be manually reset in the Latching setting.

The controller functions in two modes: “RUN” is the basic operating mode. “FUNCTION SELECT” is the password protected settings selection and control mode.
CN616TC1
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getAggregateRating, 1500ms
  • REVIEWS, PRODUCT
  • bvseo-msg: Execution timed out, exceeded 1,500ms;
  • Six-Loop PID Controller
  • Autotune or Manual Tuning
  • Heat or Cool Control
  • 20 Segments Ramp/Soak Profile Per Zone
  • Password Protected
  • User Programmable
  • RS-232 Digital Communications Standard
  • Front Panel Calibration
  • Hi, Lo or Hi/Lo Alarm, Latching or Non-Latching
  • Programmable Thermocouple Type J, K, T, R, S, E, B, or C
  • 1/4 DIN Aluminum Case
  • UL Listed (US & Canada)
  • Free Software (Fully Supported up to Windows XP)
Précision
Protocole de communication
Type de sortie de contrôle
Type d'affichage
Facteur de forme
Type d'entrée
Température ambiante maximale
Température ambiante minimale
Nombre de sorties de contrôle
Nombre de chiffres affichés
Nombre d'entrées
Autres caractéristiques
Mode de sortie
Capacité de rampe et de trempage
Résolution
Tension d'alimentation
Type de thermocouple
Voir toutes les options
Quantité Prix unitaire
1-4 C$945.00
5-10 C$888.30
11-24 C$869.40
25-49 C$812.70
50-99 C$803.25
100+ C$774.90

0 En stock

Délai de mise en œuvre: 99 semaines

Spécifications du produit

  • Protocoles de communication (variante de référence) RS-232 Single-drop daisy-chain up to 10 controllers
    RS-232 Single-drop daisy-chain up to 10 controllers
  • Sorties de contrôle / alarme, maximum 6
    6
  • Précision d'entrée analogique ±0.2% range
    ±0.2% range
  • Sorties de contrôle / alarme, standard 6 DC pulse outputs (1 per zone) designed to drive 3 to 32 Vdc input solid-state relays
    6 DC pulse outputs (1 per zone) designed to drive 3 to 32 Vdc input solid-state relays
  • Algorithmes de contrôle Autotune PID
    Autotune PID
  • Couleur d'affichage Red
    Red
  • Affichage de la hauteur des chiffres 14 mm
    14 mm
  • Température ambiante maximale 55 {C} (131 {F})
    55 {C} (131 {F})
  • Température de stockage maximale 85 {C} (185 {F})
    85 {C} (185 {F})
  • Type de mesure Temperature
    Temperature
  • Température ambiante minimale 0 {C} (32 {F})
    0 {C} (32 {F})
  • Nombre de lignes d'affichage (variante de référence) 2
    2
  • Autres éléments (variante de sku) Recorder Retransmission Software
    Recorder Retransmission Software
  • Fonction de consigne à distance Yes
    Yes
  • Taux d'échantillonnage 20 segments/loop
    20 segments/loop
  • Type de thermocouple B
    B

Description

The CN616 series has been discontinued. Please see the CN616A as a possible alternative or contact our Electronic Engineering department.

The CN616 Series is a highly versatile six-loop microprocessor-based controller designed for easy front panel or remote setup and operation. Each of six zones is sequentially scanned, and active zones are displayed. Individual zones can be locked for monitoring. Each instrument is programmable to meet operator needs for: Thermocouple Type, Temperature units Hi, Lo or Hi/Lo Alarm configured as Latching or Non-Latching and Autotune with Manual Trim or Manual PID Setting. The Zone Display Scan Time and Ramp/Soak can be set by the operator. Parameters and setpoints are retained when power is turned off. Password protection is provided to prevent accidental changes to calibration, PID setting and ramp/soak profile. If power loss occurs, the controller retains all the latest parameters and returns to “Run” mode.

All CN616 Series Controllers have RS-232 three-wire serial communications. Up to 10 units can be daisy-chained together. CN616-SOFT software is included with every unit at no charge. Windows 16/32 bit Operating Systems (Fully supported up to Windows XP)

Line Voltage is 120 Vac (110 vAC to 130 Vac)or 240 Vac (220 Vac to 260 Vac) selectable by external jumper assembly. Connections are made to the back of the instrument through easy-to-use screw terminal plugs.

The CN616 Series implements a security password to protect settings. The password can be enabled or disabled on the front panel and changed via RS-232. Calibration is performed on the front panel and is separately password protected. Higher level passwords are available.

The instrument is housed in a 1/4 DIN aluminum box which does not have to be removed for mounting. The unit mounts in a 1/4 DIN panel cutout and is secured by slide brackets. Control is done via 6 dc pulse outputs (one for each zone).

A single output relay is provided to indicate an alarm condition on any zone. The instrument shows an alarm condition by flashing the main temperature display while indicating the zone in alarm with a flashing zone number display. When set for Non-Latching, the alarm automatically resets when the condition changes. The alarm must be manually reset in the Latching setting.

The controller functions in two modes: “RUN” is the basic operating mode. “FUNCTION SELECT” is the password protected settings selection and control mode.