1/16 DIN Autotune Temperature Controllers with Modular Outputs
1/16 DIN Autotune PID/On-Off Controllers with Modular Output Options
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$622.71 |
10-24 | C$591.57 |
25-49 | C$560.44 |
50-99 | C$529.30 |
100-499 | C$498.17 |
500+ | C$467.03 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Découpe 1/16 DIN
- Entrée au choix : 9 types de Thermocouple ou Pt100
- Afficheur lumineux vert à LED 3 1/2 Digit
- 0.1° Resolution to 200°
- Constant Setpoint Deviation Indication
- Auto/Manual Output Control
- User Select from Autotune PID, PI, PD, P or On/Off Control
- Independent Second Setpoint and Output Models
- Comprehensive Alarm Features Deviation, Full Scale, Loop Break with Latching Option
- Fault Indication for Sensor Burnout, Sensor Short, Heater Break and Process Diagnostics
- Min/Max Data Storage and Autotune Diagnostics Eliminates Need for Chart Recorder
- Optional 24 Vac Power
- Field Replaceable Output Modules
CN9110A-230VAC Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Control Outputs
Input Type
Additional Feature
Output Type
Measurement Type
Form Factor
Number of Inputs
Supply Voltage Type
Display Type
The CN9000A digital temperature controllers feature high accuracy and reliability, and the sophisticated PID with approach control for optimal control during start-up and steady-state operation. These units are well suited for a broad range of applications, and are easy to install and operate. The unique, sophisticated autotune algorithm will calculate the optimum PID values, and additionally recommends the best value for cycle time. For most applications, the user need only select the desired input type, simply by using the front pushbuttons. The autotune parameters can be changed by the operator at any time, allowing the operator to fine tune the controller to an individual process.
The microprocessor holds all data in non-volatile memory, with the ability to retain data for 10 years with no power. The CN9000A has a large, 3 1/2 digit green LED readout, with auxiliary indicators for each output, and 3 LED’s to indicate deviation from setpoint.
Selection of all operational controls is made through the keys on the front panel, with the display prompting the user through each step. After the parameters have been set, they can be locked in, simply by removing a jumper located behind the front bezel. The user can select the control mode and parameters, display resolution (1 or 0.1°), and units (°F/°C). The operator can also utilize the ranging feature, which limits the range in which the setpoint may be chosen, or lock out a user from changing the setpoint. The new single setpoint controller has rear termination. The optional second setpoint and output of the CN9000A model can be set for proportional, on-off or latching limit control, and can be set as either a tracking or non-tracking setpoint. Cycle time, proportional band and on-off deadband are all set independently of the primary setpoint.
The microprocessor holds all data in non-volatile memory, with the ability to retain data for 10 years with no power. The CN9000A has a large, 3 1/2 digit green LED readout, with auxiliary indicators for each output, and 3 LED’s to indicate deviation from setpoint.
Selection of all operational controls is made through the keys on the front panel, with the display prompting the user through each step. After the parameters have been set, they can be locked in, simply by removing a jumper located behind the front bezel. The user can select the control mode and parameters, display resolution (1 or 0.1°), and units (°F/°C). The operator can also utilize the ranging feature, which limits the range in which the setpoint may be chosen, or lock out a user from changing the setpoint. The new single setpoint controller has rear termination. The optional second setpoint and output of the CN9000A model can be set for proportional, on-off or latching limit control, and can be set as either a tracking or non-tracking setpoint. Cycle time, proportional band and on-off deadband are all set independently of the primary setpoint.


RoHS 2015/863 - Voir le certificat
Approuvé CE
Composant certifié UL et cULus

Accessories