TDFS2-Series

TDFS2-1-P-06, THERMAL DISPERSION FLOW SWITCH FOR PIPE SIZE 1/2 TO 1-1/2" (15 TO 40 MM), 316SS, 1/2" BSPT PROCESS CONNECTION, 6' OF CABLE WITH CABLE GLAND (STANDARD LENGTH)

Article# TDFS2-1-P-06-BSPT

En stock

Délai de livraison (si pas en stock): 3 semaines
TDFS2-1-P-06, THERMAL DISPERSION FLOW SWITCH FOR PIPE SIZE 1/2 TO 1-1/2" (15 TO 40 MM), 316SS, 1/2" BSPT PROCESS CONNECTION, 6' OF CABLE WITH CABLE GLAND (STANDARD LENGTH) TDFS2-1-P-06-BSPT TDFS2-1-P-06-BSPT
  • Measure and control flow of liquids
  • No paddles or vanes to wear or break, no jams in the paddle movement, and no seals on movement assembly to wear or leak
  • Not affected by empty pipe by avoiding overheating with heating above the process temperature and then cooling down to process temperature
  • Lower system run cost due to low pressure drop with 10% insertion into the flow (e.g. 1/8" for 3/4" schedule 40 pipe)

TDFS2-1-P-06-BSPT Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Housing Materials
Accuracy
Wetted Materials
Compliance
Switch Type
Service
Pipe Range
Repeatability
Typical Deadband
Temperature
Pressure Limits
Response Time
Power Requirement
Switching Current
Current Consumption
Electrical Connection
Process Connection
Enclosure Rating
Input Power and Protection
Switched Output Protection


The Series TDFS2 Thermal Dispersion Flow Switch is a thermal flow switch that indicates whether the flow rate is above or below a user set flow rate. The unit incorporates two LED status indicators providing visual switch indication. The set flow rate (setpoint) is easily field adjustable with included magnet and the unit has both NO and NC NPN outputs.

loading all models
loading all reviews
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
loading all QA
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 41ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration