PST rejoint DwyerOmega. En savoir plus>
X-Series - Multi Channel Thermocouple Loggers
X-Series - 8 Channel Thermocouple Logger
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-4 | C$1,695.17 |
5-9 | C$1,661.27 |
10-24 | C$1,627.36 |
25-49 | C$1,559.56 |
50-99 | C$1,542.60 |
100+ | C$1,525.65 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Up to 4 Hz Reading Rate
- Open Channel Detection
- Configurable Channel Names
- Accepts Thermocouple Types J, K, T, E, R, S, B, N
OM-CP-OCTTCTEMP-A2 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Number of Measurements
Measurement Type
Input Type
Maximum Samples
Display
Power
Data Interface
Max Sampling Rate
Additional Feature
The new OM-CP-TCTempX Series consists of 4, 8, 12 and 16-channel thermocouple data loggers with a reading rate of up to 4 Hz. X-Series devices ship with a standard USB-A to Micro USB cable for use with free OM-CP PC based software. The X-series has a high memory capacity and increased download speed compared to previous generations of product.
In addition, the OM-CP-TCTempX Series features individual cold junction compensation for each channel providing increased accuracy and response time, and if a probe is removed or severed during logging, the software automatically annotates the data. For easy identification, each channel can be named with up to a ten digit title. To maximize memory capacity, users can enable or disable channels.
The OM-CP-TCTempX Series are ideal for a variety of applications, whether it is remote temperature monitoring, or multiple points in a central location. Data from all channels is simultaneously logged. After the monitoring cycle is complete, data can be downloaded for analysis.
Rated 5 out of
5
by
Shahrooz from
Great purchase, go ahead and place your order
It is a great datalogger. I recommend it as it is easy to use
Date published: 2023-08-07
Rated 4 out of
5
by
Justin C from
Great data logger with software that's easy to use
Works great, though I'd like it if there was an option to see data real time when doing a custom start.
Date published: 2021-10-12
Rated 5 out of
5
by
Anonymous from
The very best
It is so easy to install and use, i’d lo e the software
Date published: 2020-11-23
Rated 5 out of
5
by
Anonymous from
Rugged Stand-Alone TC Data Logger
Rugged piece of equipment that allows stand-alone logging of thermocouple data in multiple environments. Very easy to set up with the free software that is found on the OMEGA website. Retrieving the data is even easier. Just be sure to charge the battery before logging, and select the correct sample rate to avoid running out of memory. Great piece of equipment, we will be buying more in the near future.
Date published: 2020-10-15
- RoHS 2015/863 - Voir le certificat
- Approuvé CE
How can i change the sampling frequency?
Thank you for your question. You must go to Custom Start in the software to change the logging interval.
Date published: 2023-10-16
Is this Logger water resistant or water proof?
Thank you for your question. No it is not water proof or water resistant.
Date published: 2022-07-05
My new device is not appearing in the connected devices window. I've verified that it does recognize the USB that it is plugged into. My older data loggers are working correctly. Can you please help me troubleshoot this?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2023-10-24
Is it possible to poll each channel via ascii command whenever I want to record the data to a 3rd party software?
Thank you for your question. Unfortunately, there is no serial protocol available to poll logger just provided software.
Date published: 2023-09-05
I'm getting error when trying to export to excel "Unable to export to Microsoft Excel: Return argument has an invalid type." Any thoughts why?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@OMEGA.COM
Date published: 2022-11-10
Does the Data Logger comes with an extension to recharge the battery? If not, do we need to buy a new 9 V lithium battery? Thank you!
Thank you for your question. A 9 volt lithium battery is provided with the logger but this is not rechargeable and can be replaced by the user.
https://www.omega.com/en-us/data-acquisition/data-loggers/p/OM-CP-BAT103
Date published: 2022-04-28
how to you calibrate the device?
Thank you for your inquiry. Please send your request to our DAS team at das@dwyeromega.com and they will review and advise accordingly.
Date published: 2024-08-02
Does the OM-CP series software for the logger support Windows 10?
Thank you for your question. Yes, software supports Windows 10.
Date published: 2021-08-31