Gas/liquid Flow Sensors With 0 to 5 Vdc Output
Air/Water Flow Sensors with 0 to 5 Vdc Output
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- 0 to 5 Vdc Linear Output Signal
- Power Input 12 Vdc or 24 Vdc (depending on the model)
- Ranges from 20 to 100 ml/min, 100 to 500 L/min
- 1% Accuracy for Liquids/3% Accuracy for Gasses
FLR1011 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Media Type
Flow Range
Accuracy
Output Signal
Max Operating Pressure
Max Process Temperature
Wetted Materials
Process Connection Size
Display
Category
Process Connection Type
FLR1000 Series flow sensors can measure extremely low flow rates from 20 mL/min to 500 L/min. These sensors are suitable for a wide variety of industrial, commercial, and laboratory flow applications. Not for use with Hydrogen or Helium. FLR1000 Series flow sensors operate on 12 Vdc power and are designed for incorporation into data acquisition systems that supply 12.5 Vdc to sensors and receive 0 to 5 Vdc linear signals in return. Because of their cost effectiveness, FLR1000 Series units may replace conventional glass tube and ball flow meters in applications in which an electrical signal proportional to flow rate is desired.
The FLR1000 Series uses a Pelton-type turbine wheel to determine the flow rate of the gas. The rotation rate of the turbine wheel is linear over a wide dynamic range. The electro-optical system consists of a diode emitting energy in the infrared spectrum. Light energy is alternatively reflected and absorbed from "spokes" deposited on the small turbine wheel. This reflected light energy is detected by a photodiode. Thus, as the turbine wheel rotates in response to gas flow rate, electrical pulses are generated. Processing circuitry provides a DC voltage output proportional to the flow rate. For example, output signal is 1.0 Vdc at 20% of rated flow, 2.5 Vdc at 50% of rated flow, 4.0 Vdc at 80% of rated flow, and 5.0 Vdc at 100% of rated flow. Sensors can handle 20% above their rated flow without being damaged.
SPECIFICATIONS
FLR1000 Series
Accuracy: ±3% FS
Display: 3½-digit LCD, 22 mm (7/8") H
Output Signal: 0 to 5 Vdc, adjustable ±20% (typical)
Power Requirement: 11.5 to 15 Vdc regulated, 30 mA (typical)
Standard Sensor Material: 40% glass filled polyphenelene sulfide, glass window, stainless steel bearing support; sapphire shaft and bearing; FKM rubber O-rings standard
Pressure Rating: 40 psi at 20°C (68°F) for gas, 100 psi for liquid, 500 psi for brass units using liquid services
Temperature Rating: 0 to 50°C (32 to 122°F)
Temperature Sensitivity: ±0.2%/°C
Linearity: ±3% FS
Repeatability: ±0.5% FS from 50 to 100% of rated max flow for gas; ±0.2% FS for liquid
Cable Assembly: 0.9 m (3') cable length
Dimensions:
Display: 76 x 44 x 89 mm (3 x 1.75 x 3.5")
Non-Display: 60 x 42 x 37 mm (2.35 x 1.65 x 1.25")
Pressure Sensitivity: ±0.07%/mm Hg (using air at 1 to 3 atm)
Mounting: Holes for #4 screw provided
Voltage Output Models: 11.5 to 12.5 Vdc (0.4 W @ 12 Vdc)
Current Output Models: 18 to 24 Vdc (1.2 W @ 24 Vdc), 50 mA
The FLR1000 Series uses a Pelton-type turbine wheel to determine the flow rate of the gas. The rotation rate of the turbine wheel is linear over a wide dynamic range. The electro-optical system consists of a diode emitting energy in the infrared spectrum. Light energy is alternatively reflected and absorbed from "spokes" deposited on the small turbine wheel. This reflected light energy is detected by a photodiode. Thus, as the turbine wheel rotates in response to gas flow rate, electrical pulses are generated. Processing circuitry provides a DC voltage output proportional to the flow rate. For example, output signal is 1.0 Vdc at 20% of rated flow, 2.5 Vdc at 50% of rated flow, 4.0 Vdc at 80% of rated flow, and 5.0 Vdc at 100% of rated flow. Sensors can handle 20% above their rated flow without being damaged.
SPECIFICATIONS
FLR1000 Series
Accuracy: ±3% FS
Display: 3½-digit LCD, 22 mm (7/8") H
Output Signal: 0 to 5 Vdc, adjustable ±20% (typical)
Power Requirement: 11.5 to 15 Vdc regulated, 30 mA (typical)
Standard Sensor Material: 40% glass filled polyphenelene sulfide, glass window, stainless steel bearing support; sapphire shaft and bearing; FKM rubber O-rings standard
Pressure Rating: 40 psi at 20°C (68°F) for gas, 100 psi for liquid, 500 psi for brass units using liquid services
Temperature Rating: 0 to 50°C (32 to 122°F)
Temperature Sensitivity: ±0.2%/°C
Linearity: ±3% FS
Repeatability: ±0.5% FS from 50 to 100% of rated max flow for gas; ±0.2% FS for liquid
Cable Assembly: 0.9 m (3') cable length
Dimensions:
Display: 76 x 44 x 89 mm (3 x 1.75 x 3.5")
Non-Display: 60 x 42 x 37 mm (2.35 x 1.65 x 1.25")
Pressure Sensitivity: ±0.07%/mm Hg (using air at 1 to 3 atm)
Mounting: Holes for #4 screw provided
Voltage Output Models: 11.5 to 12.5 Vdc (0.4 W @ 12 Vdc)
Current Output Models: 18 to 24 Vdc (1.2 W @ 24 Vdc), 50 mA
Gas Flow Models - PPS Construction | ||||
---|---|---|---|---|
Model No. No Display | Model No. with Display | Flow Range | Max Pressure Drop | Acetal Tube Fitting |
FLR1001 | FLR1001-D | 20 to 100 mL/min | 20 Inches Water | 1/8" |
FLR1002 | FLR1002-D | 40 to 200 mL/min | 8 Inches Water | 1/8" |
FLR1003 | FLR1003-D | 100 to 500 mL/min | 2 Inches Water | 1/8" |
FLR1004 | FLR1004-D | 200 to 1000 mL/min | 2 Inches Water | 1/8" |
FLR1005 | FLR1005-D | 0.4 to 2 L/min | 2 Inches Water | 1/4" |
FLR1006 | FLR1006-D | 1.0 to 5 L/min | 2 Inches Water | 1/4" |
FLR1201 | FLR1201-D | 2.0 to 10 L/min | 3 Inches Water | 1/4" |
FLR1202 | FLR1202-D | 4.0 to 20 L/min | 3 Inches Water | 3/8" |
FLR1203 | FLR1203-D | 10 to 50 L/min | 3 Inches Water | 3/8" |
FLR1204 | FLR1204-D | 20 to 100 L/min | 3 Inches Water | 1/2" |
FLR1205 | FLR1205-D | 40 to 200 L/min | 5 Inches Water | 1/2" |
FLR1206 | FLR1206-D | 100 to 500 L/min | 20 Inches Water | 1/2" |
Liquid Flow Models - PPS Construction | ||||
---|---|---|---|---|
Model No. No Display | Model No. with Display | Flow Range | Max Pressure Drop | Acetal Tube Fitting |
FLR1007 | FLR1007-D | 13 to 100 mL/min | 10 psi | 1/8" |
FLR1008 | FLR1008-D | 20 to 200 mL/min | 10 psi | 1/4" |
FLR1009 | FLR1009-D | 50 to 500 mL/min | 10 psi | 1/4" |
FLR1010 | FLR1010-D | 100 to 1000 mL/min | 6 psi | 1/4" |
FLR1011 | FLR1011-D | 0.2 to 2 L/min | 6 psi | 1/4" |
FLR1012 | FLR1012-D | 0.5 to 5 L/min | 6 psi | 3/8" |
FLR1013 | FLR1013-D | 1.0 to 10 L/min | 10 psi | 3/8" |
Rated 4 out of
5
by
Special K from
These work as expected
We have used these in the past, so we know what to expect.
Date published: 2016-06-21
Rated 5 out of
5
by
Muhammad Azeem Ghouri from
Digital Flow Sensor
This flow sensor that I bought works well. The display makes it very convenient to control the flow rate. I highly recommend it.
Date published: 2023-07-26
Rated 5 out of
5
by
mschmid from
Easy and Reliable
We have several of these FLR series flow meters in the lab. They are easy to use, and very reliable.
Date published: 2023-04-01
Rated 5 out of
5
by
mschmid from
Perfect
The flowmeter works perfectly out of the box as advertised.
Date published: 2023-02-05
Rated 1 out of
5
by
Sarath from
VERY POOR! Wrong Reading!
Bought this flowmeter and tested it (measuring cylinder and timer)only to realise the reading was way off the mark.
Please be careful, look for a calibration certification if you plan to get one.
Date published: 2022-02-18
Rated 4 out of
5
by
Pat W from
C+ to B-
FLR1204 20-100L/min works. Spec sheet states "fast response" I did not find this to be true. Power requirements states 30mA (typical) with 11.5 V to 15.0 V supply, so 0.345 W to 0.45 W. Data logger has .4 W. Will data logger power the senor or not??? Also, the FLR1204 sensor is on a by-pass plumbing, I was not aware of this.
Date published: 2021-02-27
Rated 3 out of
5
by
Bhampton from
works and functions but limited
Purchased unit but had to return the first one due to a defect on the screen. got the second one in and it works great, in an environment without any back pressure. The second any pressure is added to the mix the gauge is rendered useless. unfortunately the testing we are performing requires some pressure while still maintaining flow and we are not able to get the value we are looking for. looking at other gauges that might have a different system to make our test work.
Date published: 2019-04-10
Rated 3 out of
5
by
sflyboy from
Warning - Will not work with Hydrogen
Will not work with Hydrogen even though the manual says call Omega for Hydrogen calibration info. Talked to an Omega engineer and was told they cant give calibration info because the unit will leak hydrogen.
Date published: 2018-02-11
- RoHS 2015/863 - Voir le certificat
- Approuvé CE
- UKCA
Can I use this meter as is to measure a water flow but also a more viscous (10 cP), transparent mix (water with honey) or do I need to do a measurement and calculate a conversion ("k") factor for the viscous fluid?
Thank you for your inquiry about this flow meter. Unfortunately, 10 cP is the maximum viscosity that the flow meter can handle or is recommended to measure. An alternative for viscous liquids is using a positive displacement flow meter.
Date published: 2021-09-22
Will this work with automotive liquids such as gasoline, diesel? If not can you suggest an alternative low flow rate meter.
Thank you for your inquiry! These flow meters incorporate infrared light into the measurement of flow rate and thus require that all fluids be translucent. Additionally, they are calibrated with water and will deviate with viscosities varying from water. Though suitable for up to 10 centistokes, accuracy may be affected by the combination of these factors. The FLR series would still be our best suited option as we do not have another offering with a similar flow range and analog output.
Date published: 2024-04-25
What is the pinout for this sensor in a 4-20 mA model? P/N FLR1009ST-I. Thank you.
Thank you for your inquiry about the flow meter. The manual outlines the wire schematic flow the "-I' flow meter such as the FLR1009ST-I meter you have. It goes as follows on page 13 of 34.
The RED wire should be connected to the Positive of the power source.
The BLACK wire should be connected to the Negative ( Ground ) of the
power source.
The WHITE wire provides the signal output (active current) and should be
connected to the positive terminal of the display, data acquisition system or
current meter with an impedance of 0 - 500Ω (Ohms).
The GREEN wire is NOT used.
Date published: 2022-01-05
Can I use this to measure the permeability of prepreg composite under a vacuum bag?
Thank you for your inquiry about the flow meter. Unfortunately, it is not recommend to use under vacuum. The FMA1700/1800A mass flow meters for gases can measure flow rate in vacuum conditions.
Date published: 2021-11-04
What is the Mfr and P/N of the electrical connector? Or, better yet, the mating connector/crimps?
Thank you for your question?
We do not sell the connector alone. If you are looking for the power supply connector, the part number for the connector and cable is FLR1000-PW for 120VAC, or FLR1000-230PW for 230VAC. If you are looking for the communication cable connector, the part number for the connector and cable is FLR1000-C.
Date published: 2019-07-08
The user's guide / manual for these units (FLR1003 / FLR1203) indicate Viton O-rings as standard, but EPDM optional. Can I order the EPDM option?
Yes. Add suffix "-EPDM" to the part number for the EPDM O ring option.
Date published: 2019-10-22
With operating Temperatures around 15 to 70 Degree Celsius and pressure ranging from 2 to 1000Kpa with water as working fluid and data to be read on Labview. I will like to know if this meter will be suitable for my desired application?
Thanks for your question. The FLR1000 series maximum working temperature is 55 degrees C. This meter cannot handle 70 degrees C.
Date published: 2020-02-03
Will this work with a coolant liquid at -10 C? The coolant is glycol-water mix.
Thanks for your question. The FLR1000 series meters have an operation temperature range of 5-55 C and a storage temperature range of 0-70 C. This meter cannot handle -10 C temperatures.
Date published: 2019-06-19
Accessories
COMPATIBLE METERS AND Accessories
4-digit precision process meter for use with voltage and current output models
C$589.59
0 In Stock