Appelez-nous au 1-888-826-6342
Débitmètres volumétriques à déplacement positif
Flowrate SensorsPour de plus amples informations veuillez contacter notre équipe commerciale.
- This product is discontinued and is replaced by BV1000-2000-3000-Series
- Measures Low Liquid Flow Rates of .13 to 7.9 GPM
- FDA Approved Materials
- Lightweight Plastic Design Permits Mounting in Any Position
FTB2001 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Flow Range
Category
Media type
Accuracy
Output Signal
Max Operating Pressure
Max Process Temperature
Wetted Materials
Process Connection Type
Process Connection Size
Display
Features
The FTB2000 series Hall-effect turbine flowrate sensor is ideal for OEM applications involving low flow liquid monitoring. The low cost, coupled with 1 /2 % repeatability, makes it an ideal candidate for replacing dispensing timer systems. Unlike existing timing systems, turbine technology is not influenced by changes in system pressure caused by aging filters. The sensor’s standard power and output specifications make it easy to retrofit to existing controllers.
SPECIFICATIONS:
Wetted Materials
Body: Nylon 12
Turbine: Nylon 12 Composite
Bearings: PTFE/15% Graphite
Accuracy: ±3% of reading
Repeatability: 0.5% of full scale
Operating Pressure: 200 psig
Operating Temperature: -20 to 100°C (-4 to 212°F )
Viscosity: 32 to 81 SSU (1.8 to 16 centistokes)
Filter: <50 microns Input
Power: 5 to 24 Vdc @ 8 mA
Output: NPN Sinking Open Collector @ 50 mA Maximum (1 to 2.2 K Ohm Pull-Up Resistor Required) (Hz Output)
Electrical Connection: Spade Terminals 2.8/6.3 x 0.8 mm (0.110/.248 x 0.031")standard
Cable 1m (3') on optional "-C" versions
Inlet/Outlet Ports: 3 /8 " NPT Male
SPECIFICATIONS:
Wetted Materials
Body: Nylon 12
Turbine: Nylon 12 Composite
Bearings: PTFE/15% Graphite
Accuracy: ±3% of reading
Repeatability: 0.5% of full scale
Operating Pressure: 200 psig
Operating Temperature: -20 to 100°C (-4 to 212°F )
Viscosity: 32 to 81 SSU (1.8 to 16 centistokes)
Filter: <50 microns Input
Power: 5 to 24 Vdc @ 8 mA
Output: NPN Sinking Open Collector @ 50 mA Maximum (1 to 2.2 K Ohm Pull-Up Resistor Required) (Hz Output)
Electrical Connection: Spade Terminals 2.8/6.3 x 0.8 mm (0.110/.248 x 0.031")standard
Cable 1m (3') on optional "-C" versions
Inlet/Outlet Ports: 3 /8 " NPT Male
Rated 4 out of
5
by
Travis k from
small sensor at an inexpensive price
Not the best sensor as far as flow sensors go but very inexpensive for a flow sensor it works good in our application of a chemical that is simalar to vegetable oil in viscosity we are using it with a plc and had to pull the voltage down from 24 v to 12 v then use a pull up resistor to be able to read pulses it word well at that point
Date published: 2017-03-01
Rated 4 out of
5
by
maktest from
Rating
Quality sensor. Don't problem. The brand we use all the time
Date published: 2020-12-21
Is this meter compatible with hydrocarbon fuels and hydrocracked base turbine oils?
Thank you for your inquiry! There should be no chemical compatibility issues with hydrocarbon fuels but we cannot guarantee chemical compatibility given possible unknowns in the process. In terms of functionality the k-factor may need to be adjusted to accurately represent the pulses per gallon for liquids other than water. This can be corrected through a field calibration.
Date published: 2021-09-15
Is it necessary to install a filter at the entrance in order to protect the Flowrate Sensors from dirt and unwanted parts that are in the water. We want to ensure that the product will not damaged.
Thank you for your inquiry about this flow meter. Yes, it would be recommended to use a filter of at least 10 microns to avoid any suspended particles to interfere with the moving turbine inside the flow meter.
Date published: 2020-08-10
About your answer: " it would be recommended to use filter of at least 10 microns to avoid suspended particles to interfere with the moving turbine of flow meter". can you recommend a specific filter? Manufacturer and P/N ? Is there such an OMEGA filter ?
Thank you for the following question. Please email flow@omega.com and will advise.
Date published: 2020-08-11
What's the pressure drop across the device as a function of flow rate(ml/s), for water, at 25 degrees C?
Thank you for your inquiry for the FTB2000 turbine flow meter. The information is shown on the data sheet on this Product Page, click on the link and you will see the Pressure Drop Curve across the entire flow range.
Date published: 2020-07-28