- Both Rate and Total Indication
- Percent Reading Accuracy
- 6-Digit Display
- FM Approved (Standard unit only)
- Signal Output Capabilities
- Reads GPM or LPM (Field Selectable)
- Battery Operated
G2S05NQ9GMA Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Flow Range
Accuracy
Process Connection Size
Media Type
Output Signal
Max Operating Pressure
Max Process Temperature
Wetted Materials
Process Connection Type
Display
Features
FTB790 Series Intrinsically Safe Turbine Meters with microprocessor-based electronics offers a durable, compact, high-precision fluid measurement device, with total and rate indication. Information is clearly displayed on a large 6-digit liquid crystal display with only 2-point floating decimal for totals from 0.01 to 999,999. All operations are easily performed with only 2 buttons.
The basic unit and display are powered by 2 AAA Alkaline batteries, providing up to 2 years of use. Cumulative total, batch total, and rate of flow are standard. A single-point field calibration curve can be stored in memory.



RoHS 2015/863 - Voir le certificat
Approuvé CE
FM
ATEX

What are the allowable mounting orientations? Vertical / flow up, vertical / flow down, horizontal?
Thank you for your inquiry about the inline flow meter. The orientation can be mounted in any position, yet, in a vertical position, the flow must go from floor to ceiling and must be full of flow at all times.
Date published: 2022-02-22
can these be utilized with nozzles?
The FTB791 requires a laminar flow in order to work properly. You cannot mount this sensor right before a nozzle. This sensor needs a straight pipe before and after the sensor. The FTB791 needs at least 15 inches of straight pipe before and 10 inches after the sensor. Please contact our Tech Support or flow@omega.com so we can fully understand your application to further advise as you need. Thank you!
Date published: 2019-05-20
Do you use any lubricant in assembly?
Thank you for your inquiry. Lubrication is not used in the assembly for the FTB790 series.
Date published: 2020-04-23
can this flow meter be used with Methylene Chloride VDG?
Thank you for your question?
Here is the the whetted materials of our meters. Please see below: Housing: 316 SS
Journal Bearings: Ceramic (96% alumina)
Shaft: Tungsten carbide
Rotor and Supports: PVDF
Retaining Rings: 316 SS