Rugged Bulb & Capillary Thermostats
$ --
Article# AR Series
Article# --
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
En stock
--
Délai de livraison (si pas en stock): 0 semaine
--
- Bulb and Capillary Design
- Long-Lasting, Snap-Action Mechanism
- Double-Pole, Single-Throw Contacts
- 3 Different Bulb Styles Available
These thermostats use sensitive bulbs that can be used in confined locations. Styles 4 and 5 bulbs are designed for inserting in drilled holes in platens and dies or for direct immersion.
Sensors for air and pipeline heating applications (style 9) can be coiled to inside radii as small as 13 mm (½inch).
SPECIFICATIONS
Temperature Range: -20 to 370°C (-4 to 698°F)
Operating Voltage:
Single-Phase: 120 to 480V
3-Phase: 120 to 277V
Enclosure: General purpose
Contacts: DPST, open on temperature rise; at positive off position, contacts cannot close
Differential: ±4% of scale
Bulb and Capillary: Copper for units rated at 120°C (248°F) and lower; nickel-plated copper for units between 95°C (203°F) and 290°C (504°F); tin-plated steel for units between 150°C (302°F) and 370°C (698°F)
Weight:
AR and ARR Series: 1.14 kg (2.5 lb)
AR-LT and AR-EP Series: 2.27 kg (5 lb)
Sensors for air and pipeline heating applications (style 9) can be coiled to inside radii as small as 13 mm (½inch).
SPECIFICATIONS
Temperature Range: -20 to 370°C (-4 to 698°F)
Operating Voltage:
Single-Phase: 120 to 480V
3-Phase: 120 to 277V
Enclosure: General purpose
Contacts: DPST, open on temperature rise; at positive off position, contacts cannot close
Differential: ±4% of scale
Bulb and Capillary: Copper for units rated at 120°C (248°F) and lower; nickel-plated copper for units between 95°C (203°F) and 290°C (504°F); tin-plated steel for units between 150°C (302°F) and 370°C (698°F)
Weight:
AR and ARR Series: 1.14 kg (2.5 lb)
AR-LT and AR-EP Series: 2.27 kg (5 lb)
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getReviews, 3ms
- REVIEWS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
- bvseo_sdk, java_sdk, bvseo-4.0.0
- CLOUD, getContent, 7ms
- QUESTIONS, PRODUCT
- bvseo-msg: The resource to the URL or file is currently unavailable.;
Demander un statut RoHS2