Appelez-nous au 1-888-826-6342
COOLING ELEMENT

Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$229.96 |
10-24 | C$218.46 |
25-49 | C$213.86 |
50-99 | C$204.66 |
100+ | C$200.07 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Made from 316L SS to Withstand Most Process Media
- 300°C (570°F) Maximum Temperature at 14,500 psi (1,000 bar)
- 5000 psi Maximum Pressure at 38°C (100°F)
- 0.4 kg (15 oz) Weight
PG-CTN2-G03 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Max Temperature
Connection Size
Max Pressure
Connection Type
Wetted Parts
Description
Extreme process temperatures reduce the accuracy, life and can possible damage pressure transmitters or gauges. The Omega cooling element is made from cast 316L stainless for maximum corrosion resistance and compatibility with process media. When used, in still air, cooling element can reduce a 300°C (570°F) liquid process temperature down to 25°C (77°F) at the active portion of the sensing element. This rugged machined bar stock construction allows the unit to operate to pressures of 100MPa (14,500 psi) at full temperature.SPECIFICATIONS
Connection: NPT male x NPT female
Body Material: 316L stainless steel
Weight: 15 oz (0.4 kg)
Operating Parameters: 200°C (570°F) maximum at 100MPa (14,500 psi)
Length: 135 mm (5.32") for -G03 or 105 mm (4.06") for -G02, maximum dia 32 mm (1.25")


Rated 5 out of
5
by
Anonymous from
Hot oil monitoring
This was purchased to monitor pressures on a heat exchanger that runs at 450f degrees with the cooling adapter installed it worked great it data logged as it should to help diagnose a problem we were having with gasket failures. I would definitely purcase again.
Date published: 2021-02-13

Do you have CRN certification for Canada?
We do not have any CRN Certification for any of our products
Date published: 2021-03-25
What is inside diameter of both go3 and go2 models
Inquiring with design engineering for this information. Will post when available.
Date published: 2023-06-19
Does it affect the pressure reading?
Thank you for your question?
The cooling element is a pass through will not effect reading?
Hope this was helpful?
Date published: 2020-03-09
How big is the hole in the center for the 1/2 npt version and also the 1/4 npt version thank you
Inquiring with design engineering. Will post information when available
Date published: 2023-06-19
Can this be used to cool a gas temperature or is it only for cooling liquids?
Thanks for connecting with Omega. The PG-CTN2-G02 is 316l Stainless Steel. You can use it with any media that is compatible with stainless steel, but please note that we do not have the heat dissipation curves for all media. The specification sheet simply states that cooling element can reduce a 300°C (570°F) liquid process temperature down to 25°C (77°F) at the active portion of the sensing element. If you are using it with gases you will have to calculate delta T for the gas you are using. Manual: https://assets.omega.com/manuals/M5166.pdf
Date published: 2022-03-04