Thin Film Pressure Transmitters, Stainless Steel Construction

Article# PX605


Thin Film Pressure Transmitters, Stainless Steel Construction PX605 PX605
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 7ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • Excellent Long Term Stability
  • NEMA 4 Cable or Connector Models
  • 0.4% Accuracy
  • Thin Film Design For High Reliability
  • Ideal for Liquid and Gas Applications
5 Year Warranty


Spécifications du produit

  • Valeur de précision 0.4
  • Excitation 10 to 30 Vdc unregulated
  • Résistance d'entrée 100 M½ @ 50 V
  • Répétabilité ±0.05%
  • Matériaux humides Stainless Steel Diaphragm

SPECIFICATIONS
Excitation: 10 to 30 Vdc unregulated
Output: 4 to 20 mA (2-wire)
Supply Current: 20 mA
Insulation Resistance: 100 M½ @ 50 V
Accuracy: ±0.4% BFSL (Includes non-linearity, hysteresis and non-repeatability errors)
±1.0% Terminal Point Method Includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors
Hysteresis: ±0.2%
Repeatability: ±0.05%
Stability: ±1.0%/year
Durability: 100 million cycles
Operating Temperature: -48 to 90°C (-55 to 195°F)
Compensated Temperature: -29 to 82°C (-20 to 180°F)
Thermal Zero Effect: ±0.07% FS/°C
Thermal Span Effect: ±0.07% FS/°C
Proof Pressure:
15 to 2000 psi = 200% Full Scale;
3000 to 5000 = 150% FS
7500 to 20000 = 120% FS
Burst Pressure:
15 to 2000 psi = 800% FS
3000 to 5000 = 500% FS
7500 to 20000 = 500% FS
Gages: Thin film polysilicon
Diaphragm: 17-4PH Stainless Steel
Case: 300 Series Stainless Steel
Pressure Connection:
15 to 10,000 psi: 1/4 NPT
15,000 and 20,000 psi = female AMINCO fitting (9/16-18 UNF)
Electrical Connection: 0.9 m (36') braided shield PVC Cable or Connector.
Mating Connector (PX615): PT06F8-4S, sold separately
Response Time: 5 ms
Construction: Sealed units, except PX605 ≤500 psi is vented to room
Weight: 128 g (4.5 oz) without cable

Examples of pricing for popular models is referenced in the 'To Order' box. Use the 'Part Number Builder' below to get pricing for all available models.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

will a px615 work in place of the px605 in the same range

Asked by: kendall
Thank you for your inquiry The only change is the PX615 will have a connector. All other features will be the same Hope this was helpful
Answered by: application engineer je
Date published: 2020-03-24
  • y_2020, m_4, d_14, h_12CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.5
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_PX605, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 3ms
  • QUESTIONS, PRODUCT
0 to 2,000 psi, Gauge, 4 to 20 mA, 1/4" NPT Male, MIL-26482-I 8-4P
C$620.00
4 In Stock
0 to 3,000 psi, Gauge, 4 to 20 mA, 1/4" NPT Male, MIL-26482-I 8-4P
C$620.00
4 In Stock