Thin Film Transducer for Gage or Vacuum, Rugged Stainless Steel Construction
0 to 100 psi, Gauge, 4 to 20 mA, 1/4" NPT Male, Cable
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$738.10 |
10-24 | C$701.20 |
25-49 | C$686.43 |
50-99 | C$656.91 |
100+ | C$642.15 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Excellent Long Term Stability
- All Stainless Steel Construction
- NEMA 4 Cable or Connector Models
- 0.4% Accuracy
PX605-100GI Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Pressure Range
Pressure Type
Output Signal
Electrical Output
Pressure Port Type
Connection/Termination
Additional Features
Accuracy Class
Accuracy Value(compensated range)
Pressure Port Size
Operating Temperature Range
SPECIFICATIONS
Excitation: 10 to 36 Vdc unregulated
Output: PX603/PX613 Series: 1 to 5 Vdc (3 wire)
PX605/PX615 Series: 4 to 20 mA (2 wire)
Supply Current: <3.0 mA
Insulation Resistance: 100 MΩ @ 50 V
Accuracy: ±0.4% BFSL (Includes non-linearity, hysteresis and non-repeatability errors)
±1.0% Terminal Point Method Includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors
Hysteresis: ±0.2% FS
Repeatability: ±0.07% FS
Stability: ±1.0%/year
Durability: 100 million cycles
Operating Temperature: -28 to 82°C (-20 to 180°F)
Compensated Temperature: -28 to 71°C (-20 to 160°F)
Thermal Zero Effect: ±0.04% FS/°F
Thermal Span Effect: ±0.04% FS/°F
Proof Pressure:
15 to 2000 psi = 200% FS
3000 to 5000 psi = 150% FS
7500 to 20,000 psi = 120% FS
Burst Pressure:
15 to 2000 psi = 800% FS
3000 to 5000 psi = 300% FS
7500 to 20,000 psi = 150% FS
Gages: Thin-film polysilicone
Diaphragm: 17-4 PH stainless steel
Case: 300 Series stainless steel
Pressure Connection:
15 to 10,000 psi = ¼ NPT
>10,000 psi = female Aminco fitting (9/16-18 UNF)
Electrical Connection: 0.9 m (36') braided-shield PVC cable or connector
Mating Connector: PT06F8-4S (not included)
Weight: 128 g (4.5 oz) without cable
Response Time: 5 ms
Construction: Sealed units, except PX603 and PX605 ≤500 psi is vented to room
Excitation: 10 to 36 Vdc unregulated
Output: PX603/PX613 Series: 1 to 5 Vdc (3 wire)
PX605/PX615 Series: 4 to 20 mA (2 wire)
Supply Current: <3.0 mA
Insulation Resistance: 100 MΩ @ 50 V
Accuracy: ±0.4% BFSL (Includes non-linearity, hysteresis and non-repeatability errors)
±1.0% Terminal Point Method Includes non-linearity, hysteresis, non-repeatability, zero offset and span setting errors
Hysteresis: ±0.2% FS
Repeatability: ±0.07% FS
Stability: ±1.0%/year
Durability: 100 million cycles
Operating Temperature: -28 to 82°C (-20 to 180°F)
Compensated Temperature: -28 to 71°C (-20 to 160°F)
Thermal Zero Effect: ±0.04% FS/°F
Thermal Span Effect: ±0.04% FS/°F
Proof Pressure:
15 to 2000 psi = 200% FS
3000 to 5000 psi = 150% FS
7500 to 20,000 psi = 120% FS
Burst Pressure:
15 to 2000 psi = 800% FS
3000 to 5000 psi = 300% FS
7500 to 20,000 psi = 150% FS
Gages: Thin-film polysilicone
Diaphragm: 17-4 PH stainless steel
Case: 300 Series stainless steel
Pressure Connection:
15 to 10,000 psi = ¼ NPT
>10,000 psi = female Aminco fitting (9/16-18 UNF)
Electrical Connection: 0.9 m (36') braided-shield PVC cable or connector
Mating Connector: PT06F8-4S (not included)
Weight: 128 g (4.5 oz) without cable
Response Time: 5 ms
Construction: Sealed units, except PX603 and PX605 ≤500 psi is vented to room
Rated 5 out of
5
by
Cody P from
Cylinder Testing
Perfect for our cycle machines! we purchase at least 3-5 of these monthly. works like a charm.
Date published: 2024-02-05
Rated 5 out of
5
by
Jim Bob II from
works well
works well for my application. cost to performance is a good value
Date published: 2023-07-26
Rated 5 out of
5
by
Good from
Good product
Good One and product quality very nice and i can see
Date published: 2023-05-11
Rated 5 out of
5
by
Anonymous from
Fantastic product
These items work very well for the application we use them for.
Date published: 2023-04-09
Rated 5 out of
5
by
Anonymous from
Used with sub ambient cannister sampling.
This worked well for our application of sub ambient cannister sampling. From -30 inHg to -6 inHg for record keeping.
Date published: 2020-11-12
Are the Model PX615-30V15GI Class I Div. 2 compliant? If not, is there a similar Omega sensor that is?
The PX605/615 Series Pressure Transmitters are not Class I Div 2 Compliant. The PX835-015CGI Intrinsically Safe Pressure Transmitter would meet you requirements.
Date published: 2021-06-30
I'm connecting the wires to my own serial connector. What are the assignments of the white, green and red cables? I'm assuming green is data, red is +VDC and white is GND. Is that correct?
Wiring would be as follows. Red is + Input Power, Green is + Output Signal, White is Common (- Input & - Signal).
Date published: 2020-03-13
Regarding product Item# PX615-20KGI: what electrical certifications does it carry for US and Canadian operations. Are they UL, ULc, or CSA compliant? Thank you!
The PX615 Series pressure transmitters are not UL, ULc or CSA Compliant.
Date published: 2019-07-24
Is there a life expectancy on the PX615 series transducer? If so how long?
Service life for PX615 is indefinite as long as it's operate within it's specified parameters. There are examples of theses sensors being in service for several years without any problems
Date published: 2019-11-16
Can I get the data from this sensor into my computer? Do you have any built-in application for this purpose or do I have to use the Data Acquisition Card to log the output voltage? If the later is true then tell me the conversion equation?
You will need to use Data Acquisition card. The out is a linear 1 to 5VDC over the sensors calibrated pressure range. You can use the linear equation y=mx+b
Date published: 2021-10-04
Do you have a drawing about the "High Pressure F-250-C", I need it to choose a fitting
Hello and thank you for your question. Could please contact the pressure department at Omega directly (pressure@omega.com)?
We would be happy to provide you with a drawing!
Date published: 2020-01-22
Absolute Pressure Models with Internal Wireless Transmitter Accessories
Accessories