text.skipToContent text.skipToNavigation

Thermocouples Probes with Connectors - Quick Disconnect - Standard Size Molded Connector

C$65.00

Article# NQIN-IM60U-600

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$65.00
10-24 C$61.75
25-99 C$58.50
100-499 C$55.25
500-999 C$52.00
1000+ C$48.75

En stock

Délai de livraison (si pas en stock): 4 semaines

Thermocouples Probes with Connectors - Quick Disconnect - Standard Size Molded Connector NQIN-IM60U-600 NQIN-IM60U-600
Thermocouples Probes with Connectors - Quick Disconnect - Standard Size Molded Connector is rated 4.8 out of 5 by 4.
  • y_2020, m_8, d_12, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.10
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_NQIN-IM60U-600, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 2ms
  • REVIEWS, PRODUCT
  • Précision classe 1
  • Connecteur mâle directement moulé sur le chemisage de la sonde
  • Connecteurs standard aux couleurs ANSI ou IEC
  • Chemisage en acier inox 304 ou 321 ou Inconel
  • Conception flexible et très robuste
  • Résiste aux vibrations, hautes températures et fortes pressions
  • Connecteur en nylon 220°C

Modifier les options

Voir tous les modèles

Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.

Sensor Type
Type de thermocouple
Process Temperature Range
Sensor Application
Sheath Material
Type de jonction
Diamètre de la sonde
Longueur de la sonde
Connector Style
Connector Color Code Standard
Additional Feature


Spécifications du produit

  • Unités de mesure °C
  • Type de mesure Air/Gas Temperature

Description

Les sondes thermocouple OMEGA™ à branchement instantané sont proposées équipées d'un connecteur standard en nylon directement moulé sur le chemisage de la sonde. Le chemisage est soit en acier inoxydable 304 ou 321 ou en Inconel.
Les tailles standards sont les suivantes:
Diamètre de sonde: 1,5 - 3 - 4,5 et 6mm
Longueur: 300 - 450 - 600mm
D'autres dimensions sont disponibles sur demande

Les prix des modèles les plus courants sont donnés dans le tableau "Pour commander".

Utilisez la table de "Construction d'une référence" ci-dessous pour obtenir les prix de tous les modèles disponibles.

Pour obtenir les caractéristiques complètes de ces sondes, cliquez sur le lien au bas de cette page.

Rated 4 out of 5 by from Thermocouple probes We use many different thermocouple types in our lab and need them quickly sometimes. We like Omega's flexibility to deliver these products with a reasonable price and availability.
Date published: 2017-06-01
Rated 5 out of 5 by from High quality Excellent product, fast shipping. Awesome selection.
Date published: 2017-11-16
Rated 5 out of 5 by from type k thermocouples a workhorse I use them at the upper limit [2000+] and get good service.
Date published: 2020-03-29
Rated 5 out of 5 by from good selection and quality We use these on our heat treat operation, they hold up well and are pretty reliable
Date published: 2018-03-22
  • y_2020, m_8, d_12, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.10
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_NQIN-IM60U-600, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT

What is the minimum temperature which the tip of the TQSS-18G-12 is rated to? Can the tip be immersed in liquid nitrogen without damage? What is the accuracy at -196 deg C?

Asked by: SeanB
Thank you for your inquiry. We do not state a minimum temperature below 0°C (32°F). Testing shows the accuracy is no longer linear. If you want the accuracy, we suggest that you get a CAL-4 Calibration at an additional cost for temperatures below 0°C. Please contact us at temp@omega.com
Answered by: Engineer CB
Date published: 2020-07-11

What is the response time for TQSS-18G-6? What is the accuracy of TQSS-18G-6?

Asked by: Wendy
Thank you for your interest in our Products .Response time for thermocouple probes are based on the following Factors . The probe diameter (the smaller the diameter the faster the response time) , If the probe is Grounded , Ungrounded or Exposed tip , and the application . For the TQSS-18G-6 , the response time in air is 1.4 seconds and in water 0.6 seconds
Answered by: SAE SAT
Date published: 2019-08-30
  • y_2020, m_8, d_12, h_15CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.10
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_NQIN-IM60U-600, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 2ms
  • QUESTIONS, PRODUCT

fr-CA
fr
Enregistrer la configuration