Skip to search Skip to main content Skip to navigation

Appelez-nous au 1-888-826-6342

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

Sondes exotiques chemisées ultra haute température <br>gainées en tantale, molybdène, platine, Inconel, titane

Very High Temperature Exotic Thermocouple Probes

C$743.60

Article# XMO-W5R26-U-125-30-A-MQ-12

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$743.60
10-24 C$706.42
25-99 C$669.24
100-499 C$632.06
500-999 C$594.88
1000+ C$557.70

En stock

Délai de livraison (si pas en stock): 4 semaines
Very High Temperature Exotic Thermocouple Probes XMO-W5R26-U-125-30-A-MQ-12 XMO-W5R26-U-125-30-A-MQ-12
  • Températures jusqu'à 2300°C selon le chemisage, le thermocouple, l'isolant et les dimensions de la sonde et l'environnement d'utilisation
  • Choix en fonction de l'atmosphère :
  • oxydante, réductrice, neutre, vide,
    et des agents polluants:
  • acides, halogènes, soufre,...
  • Chemisages:
  • Tantale
  • Molybdène
  • Platine/Rhodium
  • Titane
  • Inconel 600
  • Themocouples:
  • Tungstène/rhénium
  • Platine/rhodium
  • Isolations:
  • Oxyde d'hafnium
  • Magnésie
  • Alimine

XMO-W5R26-U-125-30-A-MQ-12 Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Thermocouple Type
Process Temperature Range
Sheath Material
Probe Diameter
Probe Length
Wire Gauge
Connector Style
Additional Feature
Sensor Type
Sensor Application
Junction Type
Connector Color Code Standard


Description

Les sondes exotiques OMEGA à thermocouple sont conçues pour l'utilisation à des températures extrêmes jusqu'à 2300°C. Elles sont construites avec des thermocouples en Platine/Rhodium (types R, S ou B) ou en Tungstène /Rhénium (types G, C ou D), et divers matériaux d'isolation et de chemisage.

Selon le matériau de chemisage choisi, ces sondes peuvent être utilisées dans des environnements inertes, oxydants, réducteurs ou sous vide. Les chemisages proposés les plus courants sont le tantale et le molybdène (*); d'autres métaux ou alliages tels que platine-rhodium, Inconel 600, titane sont également disponibles. Cinq types de terminaisons froides sont proposées : fils dénudés de 25,4mm, connecteur céramique miniature ou standard, connecteur nylon standard ou pot de jonction avec fil de 1,80m.

(*) Ces métaux réfractaires sont très sensibles à toute trace d'oxygène au-dessus d'environ 260°C. Ils doivent être utilisés sous vide ou avec des gaz inertes très purs tels que l'Hélium ou l'Argon.

Les prix de quelques modèles courants sont donnés dans le tableau "Pour commander".

Consultez notre service commercial pour tout autre configuration et prix.

Pour obtenir les caractéristiques complètes de ces produits, cliquez sur le lien au bas de cette page.
loading all models
loading all reviews
Rated 1 out of 5 by from Find a different supplier My issue with these probes is two-fold: first with the product itself and second with trying to address the product issues. The probes are not consistent from one to the next and I have contacted the engineering team to ensure that they are manufactured with tight tolerances, which they claim they do, but the following has been some of our experience. When changing thermocouples, we see high levels of temperature variation from one to the next which Omega’s provided calibration data does not account for, we have also seen vast differences in the temperature readings within a dual-probe thermocouple itself (i.e., one side reads 1000º while the other is reading 950º), we have been provided with dual thermocouples that have had the wires crossed, and so on. We are currently trying to get Omega to replace a few probes that were faulty and that has been a whole saga. First, they tried to claim that they were out of warranty, then when we were finally able to send them in and checked back a month later to find out the status, we were informed that Omega did not ever receive the probes. Upon sending them the signed delivery confirmation (then calling customer service a week later after not hearing anything) they informed us that they found the probes and could now start evaluating them. It has now been several months with zero updates even though we reach out for status updates every few weeks (which we imagine must be as annoying for them as it is for us). Do what you will with this information, but we found a new supplier.
Date published: 2021-03-17
  • y_2024, m_3, d_27, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_XMO-W5R26-U-125-30-A-MQ-12, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT
loading all QA

What kind of reader / data logger can be used to record and view the temperature readings of these ultra high temperature probes?

Asked by: Jamie B
Hi Jamie, Thank you for the inquiry. Some options; https://www.omega.com/en-us/data-acquisition/data-loggers/temperature-and-humidity-data-loggers/hh806/p/HH806AU https://www.omega.com/en-us/data-acquisition/data-loggers/multichannel-programmable-and-universal-input-data-loggers/om-cp-octpro-logger/p/OM-CP-OCTPRO And more options available. For more detail please forward request to TEMP@DWYEROMEGA.COM. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2023-10-29
  • y_2024, m_3, d_27, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_XMO-W5R26-U-125-30-A-MQ-12, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 36ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration