2 Channel Handheld 7 Thermocouple Types Datalogger USB output

2-Channel Thermocouple Thermometer with Data Logging
Warranty
  • RoHS Icon
  • Approuvé CE

C$571.43

Article# HH147AU

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$571.43
5-9 C$542.86
10-24 C$531.43
25-49 C$508.57
50-99 C$497.14
100+ C$485.72

En stock

Délai de livraison (si pas en stock): 10 semaines
2-Channel Thermocouple Thermometer with Data Logging HH147AU HH147AU
  • Entrées isolées avec protection de 350 Vcrète-à-crète entre deux entrées, peut importe lesquelles.
  • Thermomètre très précis pour utilisation avec les thermocouples de types K, J, E, T, R, S N, L, U, B et C
  • Interface USB avec logiciel fonctionnant sous Windows®
  • Alarme programmable Haute-Basse pour les 4 entrées
  • Affichage des valeurs MAX, MIN et MAX-MIN des 4 entrées
  • Configuration indépendante de chaque entrée (type de thermocouple, valeurs des alarmes Haute-Basse)
  • Fonctions Mémoire et Lecture (99 séries) avec capacité d'enregistrement automatique des données de 512 KB

HH147AU Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Measurement Type
Input Type
Maximum Samples
Display
Power
Data Interface
Additional Feature


Description

Cet instrument est un thermomètre et un enregistreur de données numérique à 4 entrées fonctionnant avec toutes les sondes de température à thermocouple de type K, J, E, T, R, S N, L, U, B et C

Conditions environnementales
Altitude :
Jusqu'à 2000 m (6562 pieds)
Humidité relative : 80% max
Température d'opération : 0 à 50°C (32 à 122°F)

Spécifications
Alimentation :
6 piles "AA" (incluses) ou adaptateur c.a. à 9Vc.c.
Durée de vie des piles : Approx. 55 heures (piles alcalines)
Mise hors tension automatique : 5, 15 ou 30 minutes (si aucune touche n'est pressée)
Indication de pile faible : L'indicateur de pile faible s'affiche lorsque la tension des piles chute sous la tension d'opération
Fréquence des mesures : Une fois toutes les 2 secondes
Poids : 405 g (14.3 oz) (piles incluses)
Dimensions : 185 L × 73 L × 53 mm H (7.3 × 2.9 × 2.1")
Température d'opération : 0 à 50°C (32 à 122°F)
   Humidité : En dessous de 80% H.R.
Température d'entreposage : -10 à 60ºC (14 à 140ºF)
   Humidité : En dessous de 70% H.R.
Coefficient de température : 0.01% de la lecture ±0.1°C par °C (0.2°F par °F) en dehors de la plage d'opération spécifiée de 18 à 28°C (64 à 82ºF)

loading all models
loading all reviews
Rated 3 out of 5 by from Works fine but user guides are terrible The unit seems fine. Like the data logging feature and exporting to be sure. Be careful of the meter's user's guide, especially Section 5.11. The guide is not clear about how to get to the functions on each step. My employees couldn't figure out how to connect it to a PC. I figured out the unit by trial and error. The software instructions are even worse. I am writing a comprehensive work instruction for my employees so they can easily use it. English was clearly not the first language for the user's guides
Date published: 2020-04-01
Rated 4 out of 5 by from Nice tool We bought it a month ago, fair enough and we're pleased with it. Perhaps it needs a better user manual but after some testings we were able to identify how some parameters should be configured.
Date published: 2017-07-17
Rated 5 out of 5 by from Simple and Works Works well. Just enable USB mode on the meter and off-loading data to your PC is quick and easy.
Date published: 2024-02-22
Rated 3 out of 5 by from Essential connection detail buried in guide Spent a couple of hours with our IT guy trying to figure out why it wouldn't connect. YOU MUST use the handheld device to turn on USB compatibility, found on page 12 of the User's Guide, although you will need to start the process on page 10 (section 5.11). If you don't see "USB" in small text on the bottom right corner of the device, your computer will not recognize the device. This step is inexplicably buried among information for less vital settings. Another source of frustration is that the program logs the temperature data in Excel in a oC/oF/oK text column that defies easy plotting, even when oC is specified in general options. If there is a setting to change this I couldn't find it and ran out of patience to keep looking. I use =LEFT(D1,4) to grab the oC digits, copy and paste values, and finally convert to number. Device has worked well so far, but the guides need a serious overhaul.
Date published: 2023-08-21
Rated 1 out of 5 by from Does not link with our computer Had our IT guy spend an hour trying to get the unit to be seen on the computer. Never got it to work. Gave up.
Date published: 2017-12-14
  • y_2024, m_4, d_17, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.41
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_CA, sid_HH147AU, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
loading all QA

What is the minimum recording time for this datalogger.

Asked by: GaryBob
The HH147AU can be set to record 1 measurement per second minimum.
Answered by: ApplicationsEngineeerANB
Date published: 2024-03-07

What is the part number for the AC Adapter?

Asked by: Zman22222
Thank you for your inquiry Zman22222. Unfortunately, the HH147Au does not have an AC adaptor because this unit is battery operated.
Answered by: Application Engineer MC
Date published: 2022-02-16

What is the response time for the thermocouples?

Asked by: GerryK
The probe included is a 30 AWG wire diameter with a beaded junction so it will be about 1.5 seconds to reach the full temperature measured.
Answered by: CTENG
Date published: 2020-04-04

What are the part numbers for type J, K and T connectors that fit this logger?

Asked by: GaryBob
The connectors used would be the miniature versions SMPW-J-M, SMPW-K-M and SMPW-T-M.
Answered by: ApplicationsEngineeerANB
Date published: 2024-03-07

Is the output of this logger also able to work with Windows 11?

Asked by: GaryBob
The Software for the HH147AU is approved compatible up to OS10.
Answered by: ApplicationsEngineeerANB
Date published: 2024-03-07

The thermometer is not detected by software, I already install all properly. "No COM" is not removed.

Asked by: Anonymous
Please contact the Temperature Engineering group for assistance temp@omega.com or 1-800-872-9436
Answered by: ApplicationsEngineeerANB
Date published: 2020-06-15

Can I calibrate this reader myself?

Asked by: GDog
You can set an offset against a reference to adjust to that standard but full calibration would require the unit be return to Omega.
Answered by: ApplicationsEngineeerANB
Date published: 2021-08-03
  • y_2024, m_4, d_18, h_3CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.41
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_7
  • loc_en_CA, sid_HH147AU, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 26ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration