Appelez-nous au 1-888-826-6342
-32 to 530°C, 12:1 Essential Infrared Thermometer
-32 to 530°C, 12:1 FOV, Infrared Thermometer
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-4 | C$83.05 |
5-9 | C$78.90 |
10-24 | C$77.24 |
25-49 | C$73.91 |
50-99 | C$72.25 |
100+ | C$70.59 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- -32 to 530°C (-26 to 986°F) temperature range
- 12:1 Field of View
- Fixed emissivity at 0.95
- 500 ms response time
- Auto power off feature
- Single laser sighting for accurate targeting
- Min/Max/Avg functions
- Get started with the quick start guide!
OS-303-121 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Mesure de la température minimale
Mesure de température maximale
Laser Output
Valeur de précision
Résolution
Input Voltage
Spectral Response
Response Time
Champ de vision
The OS303-Series essential infrared thermometer boasts 12:1 field of view, -32 to 530°C temperature range and ±2% accuracy above 0°C. This essential level device is great for basic non-contact measurement of surfaces that are far away and very high temperatures. This unit has a fixed emissivity at 0.95 perfect for many applications. The small compact size makes this unit easy to carry for all-day usage and fits comfortably in the users hand.
Applications with a 0.95 emissivity include asbestos, asphalt, oil, rubber, concrete, copper, ceramic, paper and many more. The 12:1 field of view, or distance to spot ratio, allows for precise measurement even from a larger distance.
Accuracy Chart | ||
---|---|---|
Device Accuracy = ±3°C or ±3% of rdg, -30°C to 0°C (-22 to 32°F) ±2°C or ±2% of rdg, >0°C (32°F) | ||
Target Temperature | Upper Limit Reading | Lower Limit Reading |
5°C | 7°C | 3°C |
25°C | 27°C | 23°C |
100°C | 102°C | 98°C |
150°C | 153°C | 147°C |
400°C | 408°C | 392°C |


Rated 5 out of
5
by
Onkar Raut from
Liked the product
Liked the product and perfect for my use. Thanks omega
Date published: 2022-01-19

Does the thermometer have a certificate of calibration?
Thank you for your inquiry. This product does not come with a certificate of calibration.
Date published: 2022-01-06