Skip to search Skip to main content Skip to navigation

Appelez-nous au 1-888-826-6342

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

21CFR Compliant USB Data Loggers for Vaccine & Cold Chain

Temperature Thermocouple Data Logger

C$212.22

Article# OM-EL-21CFR-TC

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$212.22
5-9 C$207.98
10-24 C$203.73
25-49 C$195.24
50-99 C$193.12
100+ C$191.00

En stock

Délai de livraison (si pas en stock): 5 semaines
Temperature Thermocouple Data Logger OM-EL-21CFR-TC OM-EL-21CFR-TC
  • Use as part of a 21CFR Part 11 compliant System for vaccine or cold chain monitoring
  • OM-EL-21CFR-TC-LCD capable of reading -100C for dry ice temperature monitoring and storage
  • Internal Sensor or External Probe Temperature Sensing models available
  • Stores 16,000 – 32,000 readings (depending on model)

OM-EL-21CFR-TC Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Measurement Type
Number of Measurements
Input Type
Temperature Measurement Range
Maximum Samples
Display
Max Sampling Rate
Additional Feature
Power
Data Interface


The OM-EL-21CFR-Series loggers are ideal for applications that require secure storage of data for critical applications such as vaccine monitoring, food and beverage, and cold chain monitoring. These standalone dataloggers are capable of storing between 16,000 to 32,000 temperature or humidity readings depending on the models outlined below.

The OM-EL-21CFR-Series offers models with internal temperature sensors as well as external probe attachments which allow for a wider temperature sensing range.

The OM-EL-21CFR-VAC is specifically designed for vaccine monitoring as it is included with a glycol buffer solution and termistor probe calibrated at 2°C and 8°C which are typical storage requirements for many vaccines.

The user can easily set up the logger and view downloaded data by plugging the data logger into a PC’s USB port and using the free Omega 21CFR software. Data can then be graphed, printed and exported to other applications for detailed analysis. The encrypted data has full audit tracking to comply with the requirements of 21CFR Part 11.

The high contrast LCD can show a variety of temperature information. At the touch of a button, the user can cycle between the current, maximum and minimum stored values for temperature.

The data logger is supplied with a lithium metal battery which typically gives 2 years’ logging life.

Omega offers models that are pre-calibrated (-NIST) with calibration points outlined below. If you require custom calibration points, please give us a call and we can help you with a custom calibration solution.

  OM-EL-21CFR-TC-LCD OM-EL-21CFR-1-LCD OM-EL-21CFR-2-LCD OM-EL-21CFR-TC OM-EL-21CFR-TP-LCD OM-EL-21CFR-TP-LCD-PLUS OM-EL-21CFR-VAC
Measurement Type Temperature Temperature Temperature, Humidity Temperature Temperature Temperature Temperature
Probe Thermocouple Probe Internal Internal Thermocouple Probe Thermistor Probe Thermistor Probe Thermistor Probe Kit w/ Glycol bottle

 

Measurement Range
-100 to 200°C
(-148 to 392°F) T-type (supplied)²
-35 to +80°C (-31 to +176°F) -35°C to 80°C (-31°F to 176°F) 0 to 200°C (32 to 392°F) K type (supplied)³ -40 to +125°C (-40 to +257°F) -40 to +125°C (-40 to +257°F) -40 to +125°C (-40 to +257°F)
0 to 100% RH
Readings 32,510 16,379 16,382 temperature, 16,382 RH 32,510 32,510 32,510 32,510
Logging Rate (User Selectable) 10 seconds to 12 hours 10 seconds to 12 hours 10 seconds to 12 hours 1 second to 12 hours 1 second to 12 hours 1 second to 12 hours 1 second to 12 hours

 

Accuracy

 

± 2.5°C typical

 

± 0.5°C typical (see graph in datasheet)

±0.55°C (1.04°F) typical (5 to 60°C)**

 

± 2.5°C typical

 

±1°C (-40 to 100°C)**

 

±0.5°C (-40 to 100°C)**

 

±0.5C (-40 to 100°C)**

±2.25 %RH typical (20 to 80%RH)**
LCD Display Yes Yes Yes No Yes Yes Yes
NIST Calibration Option Available? Yes* Yes* Yes* Yes* Yes* Yes* Included at +2C and +8C
NIST Option Calibration Points -80C 5C 25C at 50% RH 5C 5C 5C N/A
IP67 Seal No Yes Yes No No No No
Datasheet Link

OM-EL-21CFR-TC-LCD

OM-EL-21CFR-1-LCD OM-EL-21CFR-2-LCD OM-EL-21CFR-TC OM-EL-21CFR-TP-LCD OM-EL-21CFR-TP-LCD-PLUS OM-EL-21CFR-VAC

*Must order -NIST Option. For example OM-EL-21CFR-1-LCD-NIST would include a NIST certificate calibrated at 5°C. Contact us if custom calibration points are required.
**The overall error takes into account the sensor accuracy and the resolution of the logger. Please refer to datasheet.
2 Also accepts any standard T-type thermocouple with SMP connector
3 Also accepts any K, J, or T-type thermocouple with SMP connector

loading all models
loading all reviews
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
loading all QA
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 30ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
Replacement battery for OM-EL-21CFR Series
0 In Stock
Replacement Probe for the OM-EL-21CFR-TP-LCD
0 In Stock
High Accuracy Probe for the OM-EL-21CFR-TP-LCD
9 In Stock
5m Extension Cable with Thermistor Probe for OM-EL-21CFR-TP-LCD
4 In Stock
10m Extension Cable with Thermistor Probe for OM-EL-21CFR-TP-LCD
0 In Stock
Replacement glycol bottle probe for OM-EL-21CFR-VAC
0 In Stock
fr-CA
fr
Enregistrer la configuration