PST rejoint DwyerOmega. En savoir plus>
Small Diameter Immersion Thermocouple Probes with PFA cable
Fine Diameter (0.01 in. - 0.04 in.) Rugged Thermocouple Transition Joint Probes
Remises de volume disponibles
Calendrier de remise sur volume
Quantité | Prix unitaire |
---|---|
1-9 | C$89.57 |
10-24 | C$85.09 |
25-99 | C$80.61 |
100-499 | C$76.13 |
500-999 | C$71.66 |
1000+ | C$67.18 |
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Diameters as small as 0.25mm (0.010') !
- Probes Available in E, J, K, N, and T Calibrations
- 304 SS and Inconel® 600 sheaths
- Additional Sheaths Available: 310 SS, 316 SS, 321 SS and Super OMEGACLAD™ XL
TJ36-CAXL-020G-6 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
* Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente ou cliquez sur le bouton CONFIGURER pour créer la vôtre.
Thermocouple Type
Process Temperature Max
Process Temperature Range
Sensor Application
Sheath Material
Junction Type
Probe Diameter
Probe Length
Cable Length
Termination Connection Type
Category
Process Temperature Unit
Process Temperature Min
Cable Insulation
Wire Gauge
Color Code Standard
Additional Feature
OMEGA's fine diameter transition joint thermocouple probes provide durability and fast, accurate temperature measurements. Diameters as small 0.25mm (0.010") allow "pin-point" accuracy of measured values while protecting the measurement junction inside the metal sheathing and mineral insualtion of the OMEGACLAD™ cable . The metal transition barrel provides a solid mounting surface and the PFA insulated lead wire is a cost-effective solution for environmental temperatures to 260°C (500°F). For extended life, low drift operation at higher temperatures, choose Super OMEGACLAD™ XL sheathing, available in Type K and N calibrations.
Notes: *Specify Junction: (G)rounded, (E)xposed or or (U)ngrounded.
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.),
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute "NN" for CA in Model Number.
View the Thermocouple Accuracy and Color Code charts
Calibration ANSI Code | Sheath Materials | Sheath Dia. mm (in.) | T/C Junction Upper Temp. °C (°F) | Model Number (See notes, below) |
K CHROMEGA™- ALOMEGA™ | 304SS | 0.25 (0.010) 0.50 (0.020) 0.80 (0.032) 1.00 (0.040) | 500 (932) 700 (1290) 700 (1290) 700 (1290) | TJ36-CASS-010(*)-(**) TJ36-CASS-020(*)-(**) TJ36-CASS-032(*)-(**) TJ36-CASS-040(*)-(**) |
Inconel® 600 | 0.25 (0.010) 0.50 (0.020) 0.80 (0.032) 1.00 (0.040) | 500 (932) 700 (1290) 700 (1290) 700 (1290) | TJ36-CAIN-010(*)-(**) TJ36-CAIN-020(*)-(**) TJ36-CAIN-032(*)-(**) TJ36-CAIN-040(*)-(**) | |
Super OMEGACLAD™ XL | 0.25 (0.010) 0.50 (0.020) 0.80 (0.032) 1.00 (0.040) | 600 (1112) 800 (1472) 800 (1472) 800 (1472) | TJ36-CAXL-010(*)-(**) TJ36-CAXL-020(*)-(**) TJ36-CAXL-032(*)-(**) TJ36-CAXL-040(*)-(**) | |
J Iron- Constantan | 304SS | 0.25 (0.010) 0.50 (0.020) 0.80 (0.032) 1.00 (0.040) | 260 (500) 260 (500) 260 (500) 260 (500) | TJ36-ICSS-010(*)-(**) TJ36-ICSS-020(*)-(**) TJ36-ICSS-032(*)-(**) TJ36-ICSS-040(*)-(**) |
T Copper- Constantan | 304SS | 0.50 (0.020) 0.80 (0.032) 1.00 (0.040) | 260 (500) 260 (500) 260 (500) | TJ36-CPSS-020(*)-(**) TJ36-CPSS-032(*)-(**) TJ36-CPSS-040(*)-(**) |
**Specify length in inches: 6 for 150 mm (6 in.), 12 for 300 mm (12 in.),
Super OMEGACLAD™ XL probes (highlighted in yellow) are also available in N calibration; substitute "NN" for CA in Model Number.
View the Thermocouple Accuracy and Color Code charts
Rated 5 out of
5
by
Scott E from
Everything received and working as expected.
Reliable company with reliable products. Works like a charm!
Date published: 2024-04-04
Rated 5 out of
5
by
Scott E from
Great company with great products.
Everything works as expected. Received everything as expected.
Date published: 2024-04-04
Rated 1 out of
5
by
Anonymous from
Wrong reference
It is too long and too thin, I send pictures and request a quote whit a previous reference, but the reference that your teem gave me wasn't correct
Date published: 2020-09-11
Rated 5 out of
5
by
customdaveus from
0.01" fine wire T/C for speedy measurements
We use the 0.10" fine wire t/c for testing the temperature reaction time of of thermal sensing shower valves to measure the speed of the reaction time in the milliseconds.
Date published: 2020-04-10
Rated 4 out of
5
by
sully from
nice coupler great for our application.
the only problem i had was it needed to go into the side of a hot block had to bend the probe about 90' and the first one cracked.i was able to install the second one at less of an angle it was fine.
Date published: 2017-08-14
What would the transition joint diameter be for the TK36-CASS-020G-2? Could I use a thermocouple compression fitting on this? Would omegalok work for that?
Thank you for your inquiry DerekJ. The transition joint diameter is 1/4". Yes you can use compression fittings with this probe.
Date published: 2022-12-03
Over what distance at the tip does this measure temperature for this model?
The thermocouple junction is at the tip of the probe. Within the first 0.5 inch the temperature is being taken.
Date published: 2021-01-15
What is the overall length (excluding wires) of TK36-CASS-020G-2?
Thank you for your inquiry CalebK. The length of the probe is 2". The transition joint is 2.25"
Date published: 2022-12-03
In reference guide, upper temperature limit table indicates the upper temperature limit of T-TC (24AWG, 0.020 in) is 200 C. This website shows the upper temperature limit of TJ36-CPSS-020U-6 is 260 C. Which is correct?
Thank you for your inquiry. TJ36-CPSS-020U-6 has MgO Insulation that allows for higher upper temperature.
Date published: 2022-09-30
I'm looking for a thermocouple with the highest accuracy possible (range of temp from 0 to 40°C) and a 0.01" probe diameter. What is the best thermocouple for this ?
Thank you for your inquiry. We need more information in order to provide a product. Please email your request to temp@dwyeromega.com that way one of our engineers can advise.
Date published: 2024-04-06
Hello, is this probe able to be bent to a 90 degree configuration? If so, what bend radius would be achievable? My application has a very small space to operate in.
Thank you for your inquiry. Bending Metallic Sheathed Thermocouples: The Minimum Bend RADIUS Should be NO LESS than THREE TIMES the diameter of the probe being bent.
Date published: 2023-10-13