Thermocouples fins non gainés type K, T, E, N, J, R, S et B

Fine Gage Bare Wire Thermocouple Elements, J, K, T, E, N, R & S

C$48.80

Article# CHAL-015

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$48.80
10-24 C$46.36
25-99 C$43.92
100-499 C$41.48
500-999 C$39.04
1000+ C$36.60

En stock

Délai de livraison (si pas en stock): 3 semaines
Fine Gage Bare Wire Thermocouple Elements, J, K, T, E, N, R & S CHAL-015 CHAL-015
  • Disponibles sur stock conditionnés
    par lots de 5 (type K, T, E et J)
    à l'unité (type R, S et B)
  • Temps de réponse rapide
  • Mesures ponctuelles
  • Faible transfert thermique
  • Diamètres à partir de 13µm
  • Longueurs standards:
    K,T, E, J et N: 300mm (boucle de 600mm)
    R, S et B: 150mm (boucle de 300mm)

CHAL-015 Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Thermocouple Type
Process Temperature Max
Process Temperature Range
Nominal Resistance
Accuracy
Number of Wires
Cable Length
Wire Gauge
Pack Size
Additional Feature 2
Category
Process Temperature Unit
Process Temperature Min
Junction Type
Termination Connection Type
Color Code Standard


Description

Temps de réponse rapide
Les thermocouples à fils fins non gainés sont recommandés toutes les fois qu'une réponse rapide et précise à des variations de température est exigée. En raison de leur faible masse, ils ont peu d'influence sur la température du système mesuré et le transfert thermique vers le capteur est réduit au minimum.
Exemples de temps de réponse (temps nécessaire pour atteindre 63% d'un changement instantané de température):
Fil type J Ø 25µ: Air calme de 38°C à 427°C: 50ms - Courant d'air à 18m/s, de 38°C à 427°C: 4ms - Eau calme de 38°C à 93°C: 2ms.
Fil type J Ø 125µ: Air calme de 38°C à 427°C: 1s - Courant d'air à 18m/s, de 38°C à 427°C: 80ms - Eau calme de 38°C à 93°C: 40ms.
Fil type J Ø 0,38mm: Air calme de 38°C à 427°C: 10s - Courant d'air à 18m/s, de 38°C à 427°C: 0,8s - Eau calme de 38°C à 93°C: 0,4s.
Fil type J Ø 0,75mm: Air calme de 38°C à 427°C: 40s - Courant d'air à 18m/s, de 38°C à 427°C: 3,2s - Eau calme de 38°C à 93°C: 1,6s.

Mesures ponctuelles précises
Les soudures chaudes ont la forme d'une perle ayant un diamètre environ 2,5 fois celui des fils. La finesse de la soudure permet ainsi d'effectuer des mesures en des points très précis. Tous ces thermocouples sont réalisés avec du fil sélectionné avec soin, chaque lot de 5 étant constitué de fils appairés d'un même fabrication afin de garantir des propriétés thermoélectriques constantes. Si nécessaire et sans supplément de prix, plusieurs lots de 5 peuvent être livrés provenant de la même fabrication.

APPLICATIONS: • Biophysique • Recherche sur la découpe des métaux • Chromatographie • Essais de moteurs • Recherche scientifique et instrumentation • Recherche médicale • Réactions chimiques • Vaisseaux spatiaux • Chauffage industriel et étude des structures • Cryogénie • Recherche sur le plasma • Calorimétrie • Refroidissement thermoélectrique • Pétrochimie • Recherche agronomique • Contrôle de matériaux

Thermocouples courants (J,K,T,E): Les références standards sont des thermocouples de 300mm de long, conditionnés en lot de 5 . La longueur de 300mm correspond à une boucle de 600mm. D'autres longueurs sont disponibles sur demande. Pour des longueurs supérieures à 300mm, ajoutez 5€ par 300mm au prix du lot standard.

Thermocouples platine/platine rhodié: Les références standards sont des thermocouples de 150mm de long et livrés à l'unité, correspondant à une boucle de 300mm. Consultez notre service commercial pour d'autres longueurs.

Les prix des modèles les plus courants sont donnés dans le tableau "Pour commander". Utilisez la table de "Construction d'une référence" ci-dessous pour déterminer le prix des autres modèles.

Pour obtenir les caractéristiques complètes de ces produits, consultez la notice commerciale par le lien en bas de cette page.
loading all models
loading all reviews
Rated 5 out of 5 by from Clean functional Type K TC's The type K TC's we received were low cost and high quality.
Date published: 2016-09-01
Rated 5 out of 5 by from Question on CHAL-002 I bought CHAL-002 to 005 to fit my needs. They wirk great. Love them. CHAL-002 seems to fit best for my needs however the wire is so delicate that it kept breaking when I connected to controller. Any suggestions?
Date published: 2017-09-09
Rated 5 out of 5 by from Great product These thermocouples are great for measuring the temperature inside small (<1mm) aluminium packages in vacuum
Date published: 2023-09-05
Rated 5 out of 5 by from A highly anticipated order! I'm not the end user, but the lab was anxious to receive this item.
Date published: 2023-08-17
Rated 5 out of 5 by from Top notch product We can always count of Omega for excellent product quality.
Date published: 2022-03-21
Rated 5 out of 5 by from Thermocouple Battery type k omega fine gage bare wire works excellent transfering heat within a casing and two end caps.
Date published: 2020-04-13
Rated 1 out of 5 by from Unreliable Have been using Omega TCs for 40 years. The last 3 orders of small (0.001 and 0.002 inch) diameter type S thermocouples have been unreliable. Products have arrived with wires crossed and junctions 4 to 6 times the wire diameter with what appears to be black soot on wires and bead. Not all, but a significant fraction of the TCs failed to correctly register temperature. OMEGA customer service dropped the ball on my inquiries.
Date published: 2019-07-17
  • y_2024, m_3, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_7
  • loc_en_CA, sid_CHAL-015, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 2ms
  • REVIEWS, PRODUCT
loading all QA

What does &quot;bare wire&quot; mean? Are the individual wires completely bare or do they have individual electrical insulation? What I need to know is if I have to keep the pair of wires separated from each other all the way to the connector?

Asked by: JB50
Please disregard AndrewA's answer, as it is incorrect. A thermocouple's measurement depends on a junction between two dissimilar metals and a temperature differential. Those two things create an emf along the entire wire, which is measured by a voltmeter and converted into temperature according to the data tables for whichever type of TC you're using. If the two wires touch to form a *second* junction, you'll create a current loop from junction 1 (where your hot spot of interest is) and the touching point, nullifying that measurement. You'll effectively be measuring at the point closest to your voltmeter. Do NOT allow the bare wires to touch (not dangerous, but will give you erroneous readings).
Answered by: RickP
Date published: 2024-02-27

Can these measure subzero temperatures as well?&nbsp;

Asked by: vahid
Yes they bare wire Thermocouples can be used below 0C.
Answered by: ANB ENG
Date published: 2021-01-13

I have CHAL-005-BW thermocouples. How do I tell one end from the other?

Asked by: Dan It
Thank you for your inquiry Dan. One end of the thermocouple has the wires joined in the junction while the other side has the wires not join together. The junction side is the one that measures temperature.
Answered by: Application Engineer MC
Date published: 2023-11-21

What is the best way to connect a fine thermocouple (Chal-002) to a data logger? or what is the best option for extending the wire?

Asked by: Ayoub
Thank you for your inquiry Ayoub. We recommend that you use an SMPW male connector to attach the CHAL-002 wire to and then use a female connector to extend the run. The wire is so thin on the CHAL-002, you may need to &quot;fold&quot; it a few times for added support, getting it under the contact washer in the SMPW connector. But you need to realize that even, so, it is a fragile connection and much care needs to be taken not to break the wire. Please do not tighten the screw down too tight onto the wire. This can cause breakage also. Additionally, the type of extension you need depends on the data logger, you may need another male connector at the end of your run if the logger accepts a male connection- or just stripped end wire if it has terminal terminations.
Answered by: Application Engineer MC
Date published: 2023-11-21

How many connection wires do the CHAL-010 Type K have? It is not clear in the product photos. I have previously purchased other &quot;bare wire&quot; Omega thermocouples and they had 3 wires which enabled me to solder/connect to an in-house wireless module.

Asked by: TonyMTL
Thank you for your inquiry. CHAL-010 has only 2 connection wires, Chromel (+) and Alumael (-)
Answered by: Application Engineer JB
Date published: 2023-10-16

can i use these thermocouples for the measurement of surface temperatures?

Asked by: moun1992
Thank you for your inquiry! Yes, this product can be used to measure surface temperature.
Answered by: Application Engineer CK
Date published: 2021-05-25
  • y_2024, m_3, d_28, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_6
  • loc_en_CA, sid_CHAL-015, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 28ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration