PST rejoint DwyerOmega. En savoir plus>
200k LUX Handheld Light Meter
LUX Light Meter
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- HHLM3 Lux Light Meter
•Portability and Simplicity One-Hand Operation
• Accurate Visible Compensation Filter 1 is Used
•Cosine Corrected
•Lux and fc Select Function
•PEAK/DATA HOLD Function
•Pocket Hook and Magnet Hanger
•Lightweight Design
•Battery Life 300 Hrs. Typical Use - HHUVA1 UVA Meter (Ultraviolet)
•Portability and Simplicity One-Hand Operation
•Three Ranges: 199.9 µW/cm2, 1.999 mW/cm2, 19.99 mW/cm2
•MAX/DATA HOLD Function
•Pocket Hook and Magnet Hanger
•Ultraviolet Irradiance Measurement for UVA
•UV Detector Spectrum from 320 nm to 400 nm
•Battery Life 300 Hrs. Typical Use
HHLM3 Options de modèles
Voir tous les modèlesModifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.
*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.
Measurement Range
Accuracy
Operating Temperature
Supply Power
Features
Common Specifications
Display: 31/2 digit LCD with a maximum reading of 1999
Low Battery Indication: An icon is displayed when the battery voltage drops below the operating level
Battery Life: 300 Hrs. typical use
Operating Environment: 0 to 50°C (32 to 122°F), <70% relative humidity
Storage Temperature: -20 to 60°C (-4 to 140°F), 0 to 80% R.H. with battery removed from meter
Accuracy: Stated accuracy at 23°C ± 5°C (73°F ±9°F), <75% relative humidity
Dimensions: 155 H x 48 W x 24 mm D (6 x 5.8 x 4.9")
Weight: Approx. 81 g (3 oz.) including battery
Battery: 1.5V x 4 pcs AAA size, included
Battery Life: 300 hours, typical use
HHLM3 Lux Light Meter
Sensor: Silicon photodiode
Range: 20 lux, 200 lux, 2000 lux, 20000 lux, 20 fc, 200 fc, 2000 fc, 20000 fc
Resolution: 0.01 lux, 0.01 fc
Accuracy: ± (3% FS +1 digit) using a 2856 K standard light source
HHUVA1 UVA Meter (Ultraviolet)
Sensor: UV Photo diode
Range: 0 to 199.9 µW/cm2
0 to 1.999 mW/cm2
0 to 19.99 mW/cm2
Accuracy: ± (4% FS ±2 dgts) (FS: full scale)
UV Sensor Spectrum: Band pass 320-400nm
Zero: Automatic
Display: 31/2 digit LCD with a maximum reading of 1999
Low Battery Indication: An icon is displayed when the battery voltage drops below the operating level
Battery Life: 300 Hrs. typical use
Operating Environment: 0 to 50°C (32 to 122°F), <70% relative humidity
Storage Temperature: -20 to 60°C (-4 to 140°F), 0 to 80% R.H. with battery removed from meter
Accuracy: Stated accuracy at 23°C ± 5°C (73°F ±9°F), <75% relative humidity
Dimensions: 155 H x 48 W x 24 mm D (6 x 5.8 x 4.9")
Weight: Approx. 81 g (3 oz.) including battery
Battery: 1.5V x 4 pcs AAA size, included
Battery Life: 300 hours, typical use
HHLM3 Lux Light Meter
Sensor: Silicon photodiode
Range: 20 lux, 200 lux, 2000 lux, 20000 lux, 20 fc, 200 fc, 2000 fc, 20000 fc
Resolution: 0.01 lux, 0.01 fc
Accuracy: ± (3% FS +1 digit) using a 2856 K standard light source
HHUVA1 UVA Meter (Ultraviolet)
Sensor: UV Photo diode
Range: 0 to 199.9 µW/cm2
0 to 1.999 mW/cm2
0 to 19.99 mW/cm2
Accuracy: ± (4% FS ±2 dgts) (FS: full scale)
UV Sensor Spectrum: Band pass 320-400nm
Zero: Automatic
- RoHS 2015/863 - Voir le certificat
- Approuvé CE
- UKCA
Does Omega carry a model of light meter that is certified or can be certified as traceable to NIST?
Thank you for your inquiry. Unfortunately we do not have a NIST traceable light meter.
Date published: 2021-05-05
I was checking to see if this unit comes with a Certificate of calibration, when purchased. Any info is appreciated.
Thank you for your inquiry. This unit will come with Certificate of Conformance. It is for general purpose use, and does not come with certificate of calibration; also, we do not offer certification on this model. However, you may send a local cal lab to verify the specs and get data. We do stand by the specifications stated for this unit. Thank you.
Date published: 2020-01-30
Is this unit accurate on LED lights?
The measurement range for the meter is 2856 Kelvin which is basically an incandescent frequency range. There may be LED lights with the same spectrum but they very quite a bit so the meter would not be made for measuring their illuminance.
Date published: 2024-01-26