Twisted Shielded Thermocouple Duplex Extension Wire

Twisted/Shielded Thermocouple Wire and Extension Wire

C$1,795.56

Article# EXTT-K-16-TWSH-200

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$1,795.56
5-9 C$1,705.78
10-24 C$1,616.00
25-49 C$1,526.23
50-99 C$1,436.45
100+ C$1,346.67

En stock

Délai de livraison (si pas en stock): 2 semaines
Twisted/Shielded Thermocouple Wire and Extension Wire EXTT-K-16-TWSH-200 EXTT-K-16-TWSH-200
  • Blindage électrique de la gaine à l'instrument
  • Isolation de polyvinyle et PFA disponibles
  • Complète les connecteurs et sondes thermocouples à faible bruit d'OMEGA
  • Grades thermocouple et extension
  • Codes couleur disponibles en IEC et ANSI
  • Conceptions de fil sur mesure disponibles
  • Consultez le service de ventes pour les remises sur quantité

EXTT-K-16-TWSH-200 Options de modèles

Voir tous les modèles

Modifiez ces spécifications pour commander un modèle différente. Toutes les combinaisons ne sont pas valides. Les options compatibles avec les sélections précédentes seront en gras.

*Les options en surbrillance ne sont pas compatibles. Veuillez sélectionner une combinaison différente.

Temperature range
Calibre du fil
Type d'étalonnage de thermocouple
Type de câble
Conductor type
Isolation du conducteur
Overall Insulation
Overbraiding Type
Longueur de câble
Special Limit of error
Color Code Standard
Additional Feature
Category
Nombre de paires


Description

Disponible: Thermocouple grade isolation PFA(TT), thermocouple grade isolation FEP (FF), Extension grade isolation de polyvinyle (EXPP), extension grade isolation FEP(EXFF)

EXEMPLES DE MODELES COURANTS CI-DESSOUS. VEUILLEZ UTILISER LE TABLEAU CONSTRUCTEUR DE REFERENCE POUR TROUVER TOUS LES MODELES SPECIFIQUES QUI SONT DISPONIBLES.
loading all models
loading all reviews
Rated 5 out of 5 by from Thermocouple cable Good thermocouple extension cable for general use.
Date published: 2023-03-13
Rated 5 out of 5 by from Good Product Ordered Thermocouple wire and received as ordered.
Date published: 2022-09-21
Rated 5 out of 5 by from thermocouple wire works great and dependable on all of our thermocouples
Date published: 2020-11-18
Rated 3 out of 5 by from arrived on time Wish this had a shorter lead time, but other than that, it was great!
Date published: 2020-10-26
  • y_2024, m_3, d_28, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_EXTT-K-16-TWSH-200, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
loading all QA

Is there a thermocouple port with an inlet for the ground wire? If not what would be the use case for the ground wire in the thermocouple wire? What does it typically connect into?

Asked by: Temperature Reader
Thank you for your inquiry Temperature Reader. In the twisted/shielded extension wire, the copper drain wire is used to connect to earth-ground to shield the probe from electrical noise.
Answered by: Application Engineer MC
Date published: 2022-05-06

Hi, The old part number had RoHS and this do not. Is this part RoHS compliant? The website has a generic RoHS certificate but I'm not sure if it actually applies to TT-K-24-TWSH-25. Can you please confirm?

Asked by: Carlos S
Hi Carlos S, Thank you for the inquiry. Yes this product is ROHS compliant. Link to compliance cert; https://www.omega.com/en-us/rohs?rohs=rohs3&sku=TT-K-24-TWSH-25 Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2022-08-09

How many pairs are in the EXFF-K-20S-TWSH-1000

Asked by: Techy
Thank you for your inquiry! Twisted shielded thermocouple cable has only one pair of TC wire (+,-) plus an added drain wire for ground.
Answered by: Application Engineer RD
Date published: 2022-10-24

What's the voltage rating?

Asked by: Techy
Thank you for your inquiry Techy. These wires are not voltage-rated
Answered by: Application Engineer MC
Date published: 2022-10-24
  • y_2024, m_3, d_28, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_en_CA, sid_EXTT-K-16-TWSH-200, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 6ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration