313 Products found
thumbnail

Description The OM-EL-USB-CO and OM-EL-USB-CO300 are standalone USB data loggers that measure and store up to 32,510 carbon monoxide (CO) readings over a 0 to 1... Read More

OM-EL-USB-CO-Series
Price Stock Analog Input Accuracy Battery Life Battery Size Battery Type Communication Protocal Form Factor Input Range Measurement Type Memory Capacity Number of Batteries Power Source Resolution Sample Rate
Available in 6 weeks
±5 ppm or ±4% typ (whichever is greater)
3 months(with battery supplied 5 minute logging rate 25°C ambient temperature audible warning disabled
1/2 AA, 3.6V
Lithium
USB
Stand alone
0 to 300 ppm range
Carbon Monoxide
32510
1.0
battery
0.5 ppm CO
10 sec 30 sec 1 min 5 min
Available in 5 weeks
±2 ppm min ±6% typ
3 months(with battery supplied 5 minute logging rate 25°C ambient temperature audible warning disabled
1/2 AA, 3.6V
Lithium
USB
Stand alone
3 to 1000 ppm range
Carbon Monoxide
32510
1.0
battery
0.5 ppm CO
10 sec 30 sec 1 min 5 min

Description The OM-CP-HITEMP140-M12 is a rugged and versatilehigh temperature data logger featuring an M12 probeconnector. Compatible with a wide variety of M12 RTDpr... Read More

OM-CP-HITEMP140-M12-Series
Price Stock Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
Available in 0 week
±0.015 Ω ±0.05°C (±0.09°F)
2 years typical [1 minute reading rate at 25°C (77°F)]
3.6V
Lithium
316 Stainless Steel
-200 to 850°C (-328 to 1562°F)
Pt100 RTD probe with M12 connector
Temperature
43,690 readings
1.0
1.0
battery
0.0001 Ω 0.01°C (0.018°F)
4 readings per second up to 1 reading every 24 hours
thumbnail

Description The OM-CP-IRTC101A is a battery powered infrared thermocouple based temperature data logger. It provides nearly instantaneous, non-contact temperature meas... Read More

OM-CP-IRTC101A-Series
Price Stock Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Communication Protocal Form Factor Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
Available in 5 weeks
±0.25°C (±0.45°F)
10 years typical at a 15 minute reading rate
3.6V
Lithium
Flexible Probe PFA insulated cable
USB
Handheld
-40 to 80°C (-40 to 176°F)
Thermocouple (K)
Temperature
500000 readings per channel (1000000 readings total)software configurable memory wrap 250000 readings in multiple start/stop mode
1.0
1.0
battery
0.1°C (0.18°F)
1 reading every 2 seconds to 1 every 12 hours
thumbnail

Description The OM-CP-LYOTEMP data logger is designed for use in ultra-low operating temperatures for processes such as lyophilization. The OM-CP-LYOTEMP has an operat... Read More

OM-CP-LYOTEMP-Series
Price Stock Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Communication Protocal Form Factor Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
Available in 5 weeks
±0.5°C
1 year typical at a 10 minute reading rate
3.6V
Lithium
ABS Plastic white polycarbonate labeling
USB
Handheld
-60 to 75°C (-76 to 167°F)
NTC Thermistor
Temperature
32,767 readings
1.0
1.0
battery
0.1°C
1 reading every 5 seconds up to 1 reading every 30 minutes

Description The OM-CP-MOTOR101A Series measures and records on and off status changes for motors or other equipment drawing up to 200 Amps. The state change occurs whe... Read More

OM-CP-MOTOR101A-Series
Price Stock Addtional Option Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Communication Protocal Form Factor Input Range Measurement Type Memory Capacity Number of Batteries Power Source Sample Rate
Available in 5 weeks
Windows Software
Time Accuracy ±1 minute/month(at 20°C/68°F stand alone data logging)
10 years typical dependent upon frequency and duty cycle
3.6V
Lithium
ABS plastic
USB (interface cable required) 115200 baud
Plug-in
Amperage Range 0.15 to 200 A Trip Point 0.15A (150 mA) fixed (200 mA AC for 50 Hz operation)
On/Off Status
406323 readings
1.0
battery
4 Hz to 1 every 24 hr
Available in 5 weeks
Standard
Time Accuracy ±1 minute/month(at 20°C/68°F stand alone data logging)
10 years typical dependent upon frequency and duty cycle
3.6V
Lithium
ABS plastic
USB (interface cable required) 115200 baud
Plug-in
Amperage Range 0.15 to 200 A Trip Point 0.15A (150 mA) fixed (200 mA AC for 50 Hz operation)
On/Off Status
406323 readings
1.0
battery
4 Hz to 1 every 24 hr

Description The OM-CP-OCTRTD temperature logger is an 8-channel, battery powered, stand-alone, RTD based temperature recorder. This is an all-in- one compact, portable... Read More

OM-CP-OCTRTD-Series
Price Stock Addtional Option Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Communication Protocal Form Factor Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
Available in 5 weeks
Ac power
Temperature ±0.1°C @ 25°C ambient Resistance ±0.03Ω @ 25°C ambient
1 year typical
9V
Lithium
Black anodized aluminum
PC serial RS232C COM or USB (interface cable required) 2400 baud
Stand alone
Temperature -200 to 850°C (-328 to 1562°F) Resistance 0 to 500Ω
RTD
Temperature Resistance
10922 readings
1.0
8.0
Battery Universal Power Supply
Temperature 0.01°C Resistance 0.001Ω
2 sec to 12 hours selectable through software
3  In Stock
Standard
Temperature ±0.1°C @ 25°C ambient Resistance ±0.03Ω @ 25°C ambient
1 year typical
9V
Lithium
Black anodized aluminum
PC serial RS232C COM or USB (interface cable required) 2400 baud
Stand alone
Temperature -200 to 850°C (-328 to 1562°F) Resistance 0 to 500Ω
RTD
Temperature Resistance
10922 readings
1.0
8.0
Battery Universal Power Supply
Temperature 0.01°C Resistance 0.001Ω
2 sec to 12 hours selectable through software
thumbnail

Description The OM-CP-PR2000 is a battery powered recorder with a LCD display. It is perfect for applications requiring display pressures readings and a logger. The 8-... Read More

OM-CP-PR2000-Series
Price Stock Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Communication Protocal Form Factor Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 100 psia
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 300 psia
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 30 psia
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 500 psig
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 100 psig
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 300 psig
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 5000 psia
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 500 psia
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 30 psig
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
Available in 5 weeks
2% FSR 0.25% @ 25°C typical
1 year battery life at 1 min reading rate with display off. 30 days typical with continuous LCD and no backlight usage
AA
Alkaline
Black anodized aluminum case/NPT steel
PC serial or USB (interface cable required) 115200 baud
Miniature
0 to 1000 psia
Semiconductor strain gauge
Pressure
262143 total readings
6.0
1.0
battery
0.002 0.0050.02 0.05 psia/g
1 reading every 2 seconds to 1 every 24 hours
thumbnail

Description The OM-CP-PR140 is a pressure data logger designed for use in autoclave validation and mapping. This rugged device can withstand temperatures up to 1... Read More

OM-CP-PR140-Series
Price Stock Addtional Option Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Communication Protocal Form Factor Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
Available in 7 weeks
1/8 NPT pressure port
±0.03 bar (±0.435 psi) (20 to 140°C/68 to 284°F)
2 years typical
3.6V
Lithium
Stainless steel
USB (OM-CP-IFC400 interface cable required) 125000 baud
Flush Mount
Pressure 0 to 5 bar (0 to 72.5 psia)
Semiconductor strain gauge
Temperature, Pressure
32700 readings
1.0
1.0
Battery Universal Power Supply
0.1 mBar (0.0015 psia)
1 second to 1 every 24 hours
1  In Stock
Standard
±0.03 bar (±0.435 psi) (20 to 140°C/68 to 284°F)
2 years typical
3.6V
Lithium
Stainless steel
USB (OM-CP-IFC400 interface cable required) 125000 baud
Flush Mount
Pressure 0 to 5 bar (0 to 72.5 psia)
Semiconductor strain gauge
Temperature, Pressure
32700 readings
1.0
1.0
Battery Universal Power Supply
0.1 mBar (0.0015 psia)
1 second to 1 every 24 hours
thumbnail

Description The OM-CP-PHTEMP2000 is a battery powered, stand alone pH and temperature data logger with an LCD. The OM-CP-PHTEMP2000 will directly connect to many commo... Read More

OM-CP-PHTEMP2000-Series
Price Stock Analog Input Accuracy Battery Life Battery Size Battery Type Communication Protocal Form Factor Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
4  In Stock
Temperature ±0.15°C @ 25°C ambient (±0.015 Ω) pH ±0.01 pH
1 year battery life at 1 minute reading rate with display off 30 days typical with continuous display use optional AC adaptor available
9V
Lithium or Alkaline
PC serial or USB (interface cable required) 115200 baud
Stand alone
Temperature -40 to 110°C (-72 to 230°F 80 to 145 Ω)pH -2.00 to 16.00 pH
RTD
PH Temperature
131071 readings per channel
1.0
1.0
battery
Temperature 0.01°C (0.001 Ω) pH 0.01 pH (0.001 pH)
1 reading every 2 seconds to 1 every 24 hours
thumbnail

Description The OM-CP-PRHTEMP101A is a low cost, state-of-theart pressure, relative humidity and temperature data logger, specifically designed to be compact and porta... Read More

OM-CP-PRHTEMP101A-Series
Price Stock Addtional Option Analog Input Accuracy Battery Life Battery Size Battery Type Case Material Communication Protocal Form Factor Input Range Input Type Measurement Type Memory Capacity Number of Batteries Number of Input Channels Power Source Resolution Sample Rate
1  In Stock
NIST calibration certificate
Pressure 10 mbar Humidity 3% RH Temperature ±0.5°C (0.9°F)
10 years typical at a 15 minute reading rate
3.6V
Lithium
ABS plastic
USB (interface cable required) 115200 baud
Handheld
Pressure 250 to 1300 mbar Humidity 0 to 95% RH Temperature -40 to 80°C (-40 to 176°F)
Piezoresistive
Pressure Relative Humidity Temperature
Readings Per Channel 688128 Readings (Manual or Trigger Mode) 412876
1.0
1.0
battery
Pressure 0.02 mbar Humidity 0.1 %RH Temperature 0.01°C (0.018°F)
reading every second up to 1 reading every 24 hours
9  In Stock
Standard
Pressure 10 mbar Humidity 3% RH Temperature ±0.5°C (0.9°F)
10 years typical at a 15 minute reading rate
3.6V
Lithium
ABS plastic
USB (interface cable required) 115200 baud
Handheld
Pressure 250 to 1300 mbar Humidity 0 to 95% RH Temperature -40 to 80°C (-40 to 176°F)
Piezoresistive
Pressure Relative Humidity Temperature
Readings Per Channel 688128 Readings (Manual or Trigger Mode) 412876
1.0
1.0
battery
Pressure 0.02 mbar Humidity 0.1 %RH Temperature 0.01°C (0.018°F)
reading every second up to 1 reading every 24 hours