Conductivity, Resistivity, or TDS Controller
Conductivity, Resistivity or TDS Controller

Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | C$1,863.00 |
5-9 | C$1,769.85 |
10-24 | C$1,732.59 |
25-49 | C$1,658.07 |
50-99 | C$1,620.81 |
100+ | C$1,583.55 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- Monitors conductivity, resistivity and TDS in process solutions and water applications.
- Menu-Driven Programming
- NEMA 4X (IP65) Protection
- Programmable High/Low, and Alarm Relays
- Dual Backlit LCD
- Calibration Reminder Via Alarm Relay Setting
- Isolated 0.4 to 20 mA Output
- RS485 Output
- Applications
- Waste Water Treatment
- Power Plants
- Thermo-Electric Plants
- Pharmaceutical
- Photographic Industries
- Soft Drink Industries
CDCN-961 Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Measurement Type
Range
Supply Power
Output Type
Features
The CDCN-961 conductance, resistance or total dissolved solids (TDS) controller is designed for inline monitoring of process solutions and water applications.
The CDCN-961 has simple menu driven programming for easy setup. Available relays can be programmed for control, alarm or as a calibration reminder. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the buffer solution resulting in a simple and straight forward system calibration.
Specifications
Conductivity Range:
0.000 to 3.000, 30.00, 300.0 µS/cm
0.000 to 3.000, 30.00, 300.0 mS/cm
Resistivity Range:
0.3 to 30.0 M?cm
3 to 300 M?cm
TDS Range:
0.000 to 3.000, 30.00, 300.0 ppm
0.000 to 3.000, 30.00, 300.0 ppt
Resolution:
0.001/0.01/0.1 µS/cm
0.001/0.01/0.1 mS/cm
0.1 M?cm
Accuracy: ±1% FS
Temperature Range: -0.5 to 130°C (31.1 to 266°F)
Temperature Resolution /Accuracy: 0.1°C/ ±0.5°C
Cell Constant: K = 0.01, 0.1, 1, 10
Line Resistance Compensation: 0.0 to 20.0 ?
Temperature Sensor: Pt1000
Signal Output/Load: 0/4 to 20 mA/600?
Output Interface: RS485
Relay Specification: 3 SPST/250V 1A
Control Hysteresis Band: 0.1 to 10% FS
Frequency of Cleaning Time: 1 to 999 hours 1 to 999 seconds
EMC Standard: EN 50081-1/EN 50082-1
Operation Temperature: -10 to 50°C (14 to 122°F)
Operation Humidity: 10 to 95%
Housing: NEMA 4X (IP65)
Dimensions: 100 W x 108 L x 136 Dia mm (3.93 x 4.25 x 5.35")
Panel Cutout: 93.5 L x 93.5 W mm (3.68 x 3.68")
Weight: 1650 g (58 oz)
Accessory:
Conductivity Electrode: K=1.0
Material: PPS/graphite
Test Range: 0 to 50.0 mS/cm
Temperature Range: 0 to 80°C (32 to 176°F)
Temperature System: Pt1000
Cable: 5 m (16.4')
The CDCN-961 has simple menu driven programming for easy setup. Available relays can be programmed for control, alarm or as a calibration reminder. The transmitter output is also programmable from the keypad eliminating the need for potentiometer or dip-switch settings. The calibration function automatically recognizes the buffer solution resulting in a simple and straight forward system calibration.
Specifications
Conductivity Range:
0.000 to 3.000, 30.00, 300.0 µS/cm
0.000 to 3.000, 30.00, 300.0 mS/cm
Resistivity Range:
0.3 to 30.0 M?cm
3 to 300 M?cm
TDS Range:
0.000 to 3.000, 30.00, 300.0 ppm
0.000 to 3.000, 30.00, 300.0 ppt
Resolution:
0.001/0.01/0.1 µS/cm
0.001/0.01/0.1 mS/cm
0.1 M?cm
Accuracy: ±1% FS
Temperature Range: -0.5 to 130°C (31.1 to 266°F)
Temperature Resolution /Accuracy: 0.1°C/ ±0.5°C
Cell Constant: K = 0.01, 0.1, 1, 10
Line Resistance Compensation: 0.0 to 20.0 ?
Temperature Sensor: Pt1000
Signal Output/Load: 0/4 to 20 mA/600?
Output Interface: RS485
Relay Specification: 3 SPST/250V 1A
Control Hysteresis Band: 0.1 to 10% FS
Frequency of Cleaning Time: 1 to 999 hours 1 to 999 seconds
EMC Standard: EN 50081-1/EN 50082-1
Operation Temperature: -10 to 50°C (14 to 122°F)
Operation Humidity: 10 to 95%
Housing: NEMA 4X (IP65)
Dimensions: 100 W x 108 L x 136 Dia mm (3.93 x 4.25 x 5.35")
Panel Cutout: 93.5 L x 93.5 W mm (3.68 x 3.68")
Weight: 1650 g (58 oz)
Accessory:
Conductivity Electrode: K=1.0
Material: PPS/graphite
Test Range: 0 to 50.0 mS/cm
Temperature Range: 0 to 80°C (32 to 176°F)
Temperature System: Pt1000
Cable: 5 m (16.4')