PST joins DwyerOmega. Read more>
The FMA5400A/5500A Series electronic gas mass flow controllers provide for controlling the flow of a wide variety of gases from 0-10 SCCM up to 100 SLM.
Product Number | Descprition | Category | Media type | Flow Range | Accuracy | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Economical Gas Mass Controllers With or Without Integral Display
|
Controller
|
Gas
|
0.5 to 20 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
LCD
|
1,000 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
Standard
|
|
Economical Gas Mass Controllers With or Without Integral Display
|
Controller
|
Gas
|
5 to 200 SLM
|
±1.5%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
NPT Female
|
3/4"
|
Standard
|
|
Economical Gas Mass Controllers With or Without Integral Display
|
Controller
|
Gas
|
12.5 to 500 SLM
|
±1.5%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/2"
|
Standard
|
|
Economical Gas Mass Controllers With or Without Integral Display
|
Controller
|
Gas
|
25 to 1,000 SLM
|
±1.5%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
NPT Female
|
3/4"
|
Standard
|
|
Economical Gas Mass Controllers With or Without Integral Display
|
Controller
|
Gas
|
5 to 200 SLM
|
±1.5%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
LCD
|
500 psi
|
50 °C (122 °F)
|
NPT Female
|
3/4"
|
Standard
|
The FMA1700A/1800A provides measurement of direct gas mass flow rate without the need to compensate for variations in gas temperature or pressure (within stated limits).
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
1 to 100 SLM
|
±1.0%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
LCD
|
1,000 psi
|
50 °C (122 °F)
|
Compression fitting
|
3/8"
|
|
Meter
|
Gas
|
0.1 to 10 SCCM
|
±1.0%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
No Display
|
1,000 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
|
Meter
|
Gas
|
0.2 to 20 SCCM
|
±1.0%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
No Display
|
1,000 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
|
Meter
|
Gas
|
0.5 to 50 SCCM
|
±1.0%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
No Display
|
1,000 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
|
Meter
|
Gas
|
1 to 100 SCCM
|
±1.0%
|
0 to 5 Vdc, 4 to 20 mA
|
Aluminum, Brass, FKM
|
No Display
|
1,000 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
0.05 to 10 SLM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
NPT Female
|
1/8"
|
Power Supply Included
|
|
Meter
|
Gas
|
0.0025 to 0.5 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Meter
|
Gas
|
0.005 to 1 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Meter
|
Gas
|
0.05 to 10 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Meter
|
Gas
|
0.25 to 50 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
The FMA-A2100/2200/2300/2400 uses capillary-type thermal technology to directly measure mass flow of gases. No temperature, pressure, or square root corrections are required.
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
0.15 to 15 SLM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
17-4 SS, Acetal, FKM
|
LCD
|
250 psi
|
50 °C (122 °F)
|
NPT Female
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
0.1 to 10 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
17-4 SS, Acetal, FKM
|
No Display
|
250 psi
|
50 °C (122 °F)
|
NPT Female
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
0.2 to 20 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
17-4 SS, Acetal, FKM
|
No Display
|
250 psi
|
50 °C (122 °F)
|
NPT Female
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
0.5 to 50 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
17-4 SS, Acetal, FKM
|
No Display
|
250 psi
|
50 °C (122 °F)
|
NPT Female
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
1 to 100 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
17-4 SS, Acetal, FKM
|
No Display
|
250 psi
|
50 °C (122 °F)
|
NPT Female
|
1/4"
|
Power Supply Included
|
The FMA-2600A Series mass and volumetric flow controllers use the principle of differential pressure within a laminar flow field to determine and control mass flow rate.
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Controller
|
Gas
|
0.05 to 10 SLM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
NPT Female
|
1/8"
|
Power Supply Included
|
|
Controller
|
Gas
|
0.0025 to 0.5 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Controller
|
Gas
|
0.005 to 1 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Controller
|
Gas
|
0.05 to 10 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Controller
|
Gas
|
0.25 to 50 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
303 SS, Aluminum, Silicone, FKM
|
LCD
|
145 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
Using the basic FMA3100 thermal mass flow sensor, the FMA3200 mass flow controllers offer accurate control of gas flows in a compact package ideal for many OEM applications.
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
500 to 5,000 SCCM
|
±1.5%
|
Not Applicable
|
0 to 5 Vdc
|
300 SS, Aluminum, Acetal, FKM
|
No Display
|
150 psi
|
40 °C (104 °F)
|
Compression fitting
|
1/4"
|
|
Meter
|
Gas
|
2 to 20 SCCM
|
±1.5%
|
Not Applicable
|
0 to 5 Vdc
|
300 SS, Aluminum, Acetal, FKM
|
No Display
|
150 psi
|
40 °C (104 °F)
|
Compression fitting
|
1/8"
|
|
Meter
|
Gas
|
5 to 50 SCCM
|
±1.5%
|
Not Applicable
|
0 to 5 Vdc
|
300 SS, Aluminum, Acetal, FKM
|
No Display
|
150 psi
|
40 °C (104 °F)
|
Compression fitting
|
1/8"
|
|
Meter
|
Gas
|
10 to 100 SCCM
|
±1.5%
|
Not Applicable
|
0 to 5 Vdc
|
300 SS, Aluminum, Acetal, FKM
|
No Display
|
150 psi
|
40 °C (104 °F)
|
Compression fitting
|
1/8"
|
|
Meter
|
Gas
|
20 to 200 SCCM
|
±1.5%
|
Not Applicable
|
0 to 5 Vdc
|
300 SS, Aluminum, Acetal, FKM
|
No Display
|
150 psi
|
40 °C (104 °F)
|
Compression fitting
|
1/8"
|
The FMA-4100/4300 Series flow rate can be displayed in 23 different volumetric flow or mass flow engineering units including a user specific selection with remote programming
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
0.1 to 5 SCCM
|
±1%
|
RS232
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
1 SPDT 1A relay
|
|
Meter
|
Gas
|
0.2 to 10 SCCM
|
±1%
|
RS232
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
1 SPDT 1A relay
|
|
Meter
|
Gas
|
0.4 to 20 SCCM
|
±1%
|
RS232
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
1 SPDT 1A relay
|
|
Meter
|
Gas
|
1 to 50 SCCM
|
±1%
|
RS232
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
1 SPDT 1A relay
|
|
Meter
|
Gas
|
2 to 100 SCCM
|
±1%
|
RS232
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, Aluminum, Brass, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
1 SPDT 1A relay
|
The FMC-5000 Coriolis Mass Flow Meter is widely used for flow measurements and custody transfer in industries such as petroleum, chemical, pharma, food and dairy, and more.
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Liquid
|
200 to 3,000 kg/h
|
±0.1%
|
RS485
|
0 to 10 kHz, 4 to 20 mA
|
304 SS, 316 SS
|
LCD
|
230 psi
|
125 °C (257 °F)
|
Flange - ANSI
|
1/2"
|
Integral Display
|
|
Meter
|
Liquid
|
200 to 3,000 kg/h
|
±0.1%
|
RS485
|
0 to 10 kHz, 4 to 20 mA
|
304 SS, 316 SS
|
LCD
|
230 psi
|
125 °C (257 °F)
|
Flange - DIN
|
1/2"
|
Integral Display
|
|
Meter
|
Liquid
|
200 to 3,000 kg/h
|
±0.1%
|
RS485
|
0 to 10 kHz, 4 to 20 mA
|
304 SS, 316 SS
|
LCD
|
230 psi
|
125 °C (257 °F)
|
Flange - JIS
|
1/2"
|
Integral Display
|
|
Meter
|
Liquid
|
200 to 3,000 kg/h
|
±0.1%
|
RS485
|
0 to 10 kHz, 4 to 20 mA
|
304 SS, 316 SS
|
LCD
|
230 psi
|
125 °C (257 °F)
|
Tri-Clamp
|
1/2"
|
Integral Display
|
|
Meter
|
Liquid
|
600 to 8,000 kg/h
|
±0.1%
|
RS485
|
0 to 10 kHz, 4 to 20 mA
|
304 SS, 316 SS
|
LCD
|
230 psi
|
125 °C (257 °F)
|
Flange - ANSI
|
1"
|
Integral Display
|
The FMA-LP1600A Series mass and volumetric flowmeters use the principle of differential pressure within a laminar flow field to determine the mass flow rate.
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
0.0025 to 0.5 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Meter
|
Gas
|
0.005 to 1 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Meter
|
Gas
|
0.05 to 10 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Meter
|
Gas
|
0.25 to 50 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
NPT Female
|
1/8"
|
Power Supply Included
|
|
Meter
|
Gas
|
0.01 to 2 SLM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
NPT Female
|
1/8"
|
Power Supply Included
|
The FLR-1600A and FLV-4600A series flowmeters and controllers use two of the best studied physical properties of liquids to measure flow: Pressure and Viscosity.
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Liquid
|
0.001 to 0.5 SCCM
|
±2%
|
0 to 5 Vdc
|
300 Series SS, FKM, Polythermide, Glass, Silicone
|
LCD
|
100 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Not Applicable
|
|
Meter
|
Liquid
|
0.02 to 1 SCCM
|
±2%
|
0 to 5 Vdc
|
300 Series SS, FKM, Polythermide, Glass, Silicone
|
LCD
|
100 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Not Applicable
|
|
Meter
|
Liquid
|
0.2 to 10 SCCM
|
±2%
|
0 to 5 Vdc
|
300 Series SS, FKM, Polythermide, Glass, Silicone
|
LCD
|
100 psi
|
50 °C (122 °F)
|
NPT Female
|
1/8"
|
Not Applicable
|
|
Meter
|
Liquid
|
1 to 50 SCCM
|
±2%
|
0 to 5 Vdc
|
300 Series SS, FKM, Polythermide, Glass, Silicone
|
LCD
|
100 psi
|
50 °C (122 °F)
|
NPT Female
|
1/8"
|
Not Applicable
|
|
Meter
|
Liquid
|
0.04 to 2 LPM
|
±2%
|
0 to 5 Vdc
|
300 Series SS, FKM, Polythermide, Glass, Silicone
|
LCD
|
100 psi
|
50 °C (122 °F)
|
NPT Female
|
1/4"
|
Not Applicable
|
FMA2700/FMA2800 Series Electronic Mass Flowmeters and FMA3700/FMA3800 Mass Flow Controllers are perfect for gas flow application which require an all stainless steel design
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
0.1 to 10 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, FKM
|
LCD
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
0.2 to 20 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, FKM
|
LCD
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
0.5 to 50 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, FKM
|
LCD
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
1 to 100 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, FKM
|
LCD
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
Power Supply Included
|
|
Meter
|
Gas
|
2 to 200 SCCM
|
±1%
|
0 to 5 Vdc, 4 to 20 mA
|
316 SS, FKM
|
LCD
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
Power Supply Included
|
FMA6500 Series flow controllers allow one to program, record, and analyze flow rates of various gases with a computer via an RS485 interface (optional RS232 is available).
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Controller
|
Gas
|
0.2 to 10 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
2 SPDT 1A Relay
|
|
Controller
|
Gas
|
0.4 to 20 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
2 SPDT 1A Relay
|
|
Controller
|
Gas
|
1 to 50 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
2 SPDT 1A Relay
|
|
Controller
|
Gas
|
2 to 100 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
2 SPDT 1A Relay
|
|
Controller
|
Gas
|
4 to 200 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, 416 SS, FKM
|
No Display
|
500 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
2 SPDT 1A Relay
|
The FMA-LP2600A controller uses a proportional valve coupled to the flow body to control flow using the integral PID loop controller. 0 to 5V output (4 to 20 mA optional)
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Controller
|
Gas
|
1.25 to 250 SLM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
NPT Female
|
3/4"
|
Power Supply Included
|
|
Controller
|
Gas
|
0.0025 to 0.5 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Controller
|
Gas
|
0.005 to 1 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Controller
|
Gas
|
0.05 to 10 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
UNF Female
|
10-32
|
Power Supply Included
|
|
Controller
|
Gas
|
0.25 to 50 SCCM
|
±0.8%
|
RS232
|
0 to 5 Vdc
|
300 SS, Aluminum, Silicone, FKM
|
LCD
|
50 psi
|
50 °C (122 °F)
|
NPT Female
|
1/8"
|
Power Supply Included
|
All features of the FMA6600 and FMA6700 Series flow meters can be accessed via the local keypad and LCD. The digital interface operates via RS485 (optional RS-232 available)
Product Number | Category | Media type | Flow Range | Accuracy | Communications Protocol | Output Signal | Wetted Materials | Display | Max Operating Pressure | Max Process Temperature | Process Connection Type: | Process Connection Size: | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Gas
|
1 to 50 SCCM
|
±1%
|
RS485
|
0 to 5 Vdc
|
316 SS, FKM
|
LCD
|
100 psi
|
50 °C (122 °F)
|
Compression fitting
|
1/4"
|
2 SPDT 1A Relay, Multi-parameter Display
|