The LVR500 Series float level transmitter provides continuous level measurement up to 2 m (6.5') with a 4 to 20 mA signal output, and is factory configured to your selected dimension. This stainless steel liquid level sensor is well suited for high temperature or pressure tank level applications with relatively clean liquids such as water, diluted chemicals and light weight oils. Typical application examples include boilers and process vessels.
Specifications Range: 41 to 1222 cm (16 to 48") Accuracy: 0.25% span in water Configuration: None, fixed span Orientation: ±20° from vertical Specific Gravity: 0.55 min Supply Voltage: 10 to 30 Vdc Loop Resistance: 600 ? @ 24 Vdc Signal Output: 4 to 20 mA, two-wire Process Temp: -40 to 85°C (-40 to 185°F) Ambient Temp: -40 to 60°C (-40 to 140°F) Pressure: 200 psi (13.8 bar) Enclosure Rating: NEMA 4X (IP65) Enclosure Material: PP Conduit Entrance: Single, 1/2 NPT Process Mount: 2 NPT Guide-Float Material: 316 SS Classification: General purpose Compliance: CE
The description says this is available up to 2 meters, but the listed models have a range up to 48", please explain
Asked by: MikeE
Thank you for your inquiry
Omega can provide a longer length to measure the level and request that he send his specified or desired length to flow@omega.com and can prepare a quote
Answered by: application engineer je
Date published: 2021-01-28
Do you sell just the float for this unit?
Asked by: Vallot
Thank you for your inquiry! Unfortunately, we do not sell the float as a separate component
Answered by: Application Engineer JM
Date published: 2022-02-28
What is the current draw of this device?
Asked by: Trevor R
Thank you for your inquiry. The current draw is 40 mA via the recommended 24 VDC power source.