en
Save Configuration
text.skipToContent text.skipToNavigation
Configure Product
Saved Configuration
View Configuration
Terms and Conditions

Humidity Meters

36 Products found

Replacement industrial probe 51 mm (2'), 0.9 m (3') cable Read More

Replacement industrial probe 137 mm (5'), 3 m (10') cable Read More

Replacement Industrial 137mm (5') Probe, cable 3m (10 ft) with stripped wire leads and NIST traceable calibration certificate Read More

thumbnail

Field replaceable remote probe with 3 m (10') cable and M12 connecto Read More

thumbnail

Field replaceable 71.88 L mm (2.83') short probe with M12 connector Read More

Description The HX80A Series is a family of humidity probes that offer a variety of measurement parameters with precision accuracy: relative humidity and temperature,... Read More

HX80A
Price Stock Accuracy Value Data Logging Maximum Temperature Measurement Measurement Type Minimum Temperature Measurement Output Type Response Time
±1% RH
No
120°C (248°F)
RH Pressure Barometric pressure
-20°C (-4°F)
4 to 20 mA
<15 sec air flow dependent (for 66.6% response)
±1% RH
No
120°C (248°F)
RH Temperature Pressure
-20°C (-4°F)
4 to 20 mA
<15 sec air flow dependent (for 66.6% response)
±1% RH
No
120°C (248°F)
RH Temperature Pressure
-20°C (-4°F)
0 to 10 Vdc
<15 sec air flow dependent (for 66.6% response)
±1% RH
No
120°C (248°F)
RH/temperature/dew point transmitter
-20°C (-4°F)
0 to 10 Vdc
<15 sec air flow dependent (for 66.6% response)
±1% RH
No
120°C (248°F)
RH Temperature Barometric pressure
-20°C (-4°F)
0 to 10 Vdc
<15 sec air flow dependent (for 66.6% response)
±1% RH
No
120°C (248°F)
RH Dew point Temperature
-20°C (-4°F)
4 to 20 mA
<15 sec air flow dependent (for 66.6% response)

Description The HX400 Series transmitters provide remote and on-site monitoring of relative humidity and temperature. Each parameter is transmitted as a 4 to 20 mA si... Read More

HX400
Price Stock Accuracy Value Data Logging Form Factor Maximum Temperature Measurement Measurement Type Minimum Temperature Measurement Output Type Response Time
±0.02 mA
No
Wall Mount
70°C (158°F)
Humidity Temperature
-20°C (-4°F)
Two Isolated SSR Output
10 seconds (relative humidity) 30 seconds maximum (temperature)
±0.02 mA
No
Remote probe
70°C (158°F)
Humidity Temperature
-20°C (-4°F)
Two Isolated SSR Output
10 seconds (relative humidity) 30 seconds maximum (temperature)
±0.02 mA
No
Duct Mount
70°C (158°F)
Humidity
-20°C (-4°F)
Two Isolated SSR Output
10 seconds (relative humidity) 30 seconds maximum (temperature)
±0.02 mA
No
Remote probe
70°C (158°F)
Humidity
-20°C (-4°F)
Two Isolated SSR Output
10 seconds (relative humidity) 30 seconds maximum (temperature)
±0.02 mA
No
Wall Mount
70°C (158°F)
Humidity
-20°C (-4°F)
Two Isolated SSR Output
10 seconds (relative humidity) 30 seconds maximum (temperature)
±0.02 mA
No
Duct Mount
70°C (158°F)
Humidity Temperature
-20°C (-4°F)
Two Isolated SSR Output
10 seconds (relative humidity) 30 seconds maximum (temperature)

Description The HX200 is a high accuracy calibrated dew point or humidity transmitter. The remote sensor is designed to work at temperatures as high as 200°C (392°F).... Read More

HX200
Price Stock Accuracy Value Data Logging Maximum Temperature Measurement Measurement Type Output Type
±1% RH from 15 to 40°C (59 to 104°F) 0 to 90% RH (non-condensing) ±2% RH below 15°C (59°F) or above 40°C (104°F)
No
200°C (392°F)
Relative Humidity
4 to 20 mA loop powered
±1.0°C from -20 to 40°C (-4 to 104°F) ±3.0°C below -20°C (-4°F)
No
200°C (392°F)
Dew point
4 to 20 mA loop powered

Description The HX92B Series transmitters provide remote and on-site monitoring of relative humidity. It is available with either voltage or 2-wire current output. Th... Read More

HX92B
Price Stock Accuracy Value Data Logging Form Factor Maximum Temperature Measurement Measurement Type Minimum Temperature Measurement Output Type Response Time
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Remote probe
75°C (167°F)
Humidity
-30°C (-22°F)
4 to 20 mA
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Duct Mount
75°C (167°F)
Humidity
-30°C (-22°F)
4 to 20 mA
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Duct Mount
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 1 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Duct Mount
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 5 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Duct Mount
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 10 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Remote probe
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 5 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Wall Mount
75°C (167°F)
Humidity
-30°C (-22°F)
4 to 20 mA
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Wall Mount
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 10 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Remote probe
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 10 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Wall Mount
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 1 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Wall Mount
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 5 Vdc
8 second typical
±2.5% from 20 to 80% RH ±3.5% from 5 to 20% and 80 to 95% RH ±4% from 0 to 5% and 95 to 100% RH
No
Remote probe
75°C (167°F)
Humidity
-30°C (-22°F)
0 to 1 Vdc
8 second typical

Description The HX93B and HX93BD Series transmitters provide remote and on-site monitoring of temperature and relative humidity. Both series output a linearized curre... Read More

HX93B
Price Stock Accuracy Value Additional Option Data Logging Form Factor Maximum Temperature Measurement Measurement Type Minimum Temperature Measurement Output Type Response Time
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
4 to 20 mA
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
4 to 20 mA
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 1 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 5 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 10 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 5 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 10 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 10 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 5 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 10 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
4 to 20 mA
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
4 to 20 mA
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 1 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
4 to 20 mA
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Duct Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 1 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
4 to 20 mA
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 1 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 5 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 5 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 10 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Digital Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 1 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 5 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Remote probe
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 1 Vdc
5 seconds minimum 30 seconds maximum
Temperature ±0.6°C from 0 to 50°C (32 to 122°F) ±1.25°C from -30 to 0°C (-22 to 32°F) 50 to 75°C (122 to 167°F) Relative Humidity ±2.5% from 20 to 80% RH ±3.5% from 5 to 20% 80 to 95% RH ±4% from 0 to 5% 95 to 100% RH
Standard Display
No
Wall Mount
Standard 75°C (167°F) Special 75°C (167°F)
Temperature Relative Humidity
Standard -30°C (-22°F) Special -20°C (-4°F)
0 to 10 Vdc
5 seconds minimum 30 seconds maximum