Description The TXDIN1600S is a “smart” powered bridge amplifier for use with strain gauges or load cell signals. The product has a built-in capability to scale the i... Read More

TXDIN1600S-Series
Price Stock Enclosure Material Input Ranges Input Type Number of Inputs Output Type Supply Voltage
Available in 5 weeks
DIN rail enclosure offering Protection ≥ IP65
-7.6 to 7.6 mV/V (-38 to 38) mV at 5V excitation
Bridge
1.0
Universal Current Bipolar Voltage Outputs
10 to 48 Vdc 10 to 32 Vac
OMB-DBK15-Series
Price Stock Connection Type Input Ranges Input Type Number of Inputs Output Type
2  In Stock
DB37 male mates with P1 pinout on the OMB-LOGBOOK
±20 mA max 0 to +10 Vdc ±5 Vdc
Current Voltage
2.0
Current Voltage
OM-SGD-ADPT-TC-Series
Price Stock Input Ranges Input Type Number of Inputs Thermocouple Type
10  In Stock
J -200 to 1190°C (-328 to 2174°F) K -200 to 1350°C (-328 to 2462°F) T -200 to 390°C (-328 to 734°F)
Thermocouple
1.0
J K T

Description The TXDIN1600 Series is a new generation DIN rail mounted temperature transmitter. It has been designed to accept most common process and temperature sens... Read More

TXDIN1600-Series
Price Stock Connection Type Input Ranges Input Type Isolation Number of Inputs Output Type RTD Types Supported Supply Voltage Thermocouple Type
4  In Stock
Screw terminals
K -200 to 1370°C (-328 to 2498°F) J -100 to 1200°C (-148 to 2192°F) E -100 to 1000°C (-148 to 1832°F) N -180
Thermocouple RTD Millivolt Milliamp
Input to output tested at 500 Vdc
4.0
4 to 20 mA
Pt100
15 to 28 Vdc
K J E N T R S
38  In Stock
Screw terminals
K -200 to 1370°C (-328 to 2498°F) J -100 to 1200°C (-148 to 2192°F) E -100 to 1000°C (-148 to 1832°F) N -180
Thermocouple RTD Millivolt Milliamp
Input to output tested at 500 Vdc
4.0
4 to 20 mA
Pt100
24 Vdc
K J E N T R S

Description The TX401 and TX402 head mount temperature transmitters transform a temperature signal acquired from a Pt100, Pt1000 (TX401 only) or Ni100 RTD sensor or f... Read More

TX400-Series
Price Stock Connection Type Enclosure Material Input Ranges Input Type Isolation Number of Inputs Output Type RTD Types Supported Supply Voltage Thermocouple Type
20  In Stock
Screw terminals
Nylon (PA66)
-200 to 800°C (-328 to 1472°F)
RTD
Non-isolated
1.0
4 to 20 mA
Pt1000 Ni100
6 to 32 Vdc
Not Applicable
Available in 7 weeks
Screw terminals
Nylon (PA66)
-200 to 600°C (-328 to 1112°F)
Thermocouple RTD Millivolt
galvanic 1 KVac input/output
3.0
4 to 20 mA
Ni100
6 to 32 Vdc
J K T E R S B N
thumbnail

Description The OM5 series modular signal conditioners provide a low cost, high performance method of inter-connecting real-world analog signals with data acquisition... Read More

OM5
Price Stock Additional Option Excitation Input Ranges Input Type Number of Inputs Output Type RTD Types Supported Supply Voltage Thermocouple Type
Available in 7 weeks
Standard
10 Vdc
±2 Vdc
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
-100 to 1300°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
N
Available in 7 weeks
Standard
10 Vdc
-100 to 400°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
T
Available in 7 weeks
Standard
10 Vdc
±1 V
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 5 Vdc
Current
1.0
0 to 20 mA
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±1 Vdc
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±10 Vdc
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±3 Vdc
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 25 KHz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 3 KHz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 50 KHz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
1  In Stock
Standard
10 Vdc
±100 mV
Millivolt
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
4 to 20 mA
Current
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±10 mV
Millivolt
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±100 mV
Millivolt
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 300°C
RTD
1.0
0 to 5 Vdc
Nickel 2 or 3 Wire
5 Vdc
Not Applicable
6  In Stock
Standard
10 Vdc
±50 mV
Millivolt
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±50 mV
Millivolt
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 100°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 4 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 600°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 4 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
-100 to 100°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 2 or 3 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 900°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
E
Available in 7 weeks
Standard
10 Vdc
0 to 1750°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
S
Available in 7 weeks
Standard
10 Vdc
±10 V
Voltage
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±1 V
Voltage
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±40 Vdc
Voltage
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±5 V
Voltage
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 5 Vdc
Current
1.0
4 to 20 mA
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±5 Vdc
Current
1.0
4 to 20 mA
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 1000°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
E
Available in 7 weeks
Standard
10 Vdc
0 to 1000°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
K
Available in 7 weeks
Standard
10 Vdc
0 to 500°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
J
Available in 7 weeks
Standard
10 Vdc
500 to 1750°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
S
Available in 7 weeks
Standard
10 Vdc
10K Ω
Resistance
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
1  In Stock
Full bridge 300-10 kΩ
10 Vdc
±20 mV @ 10 V Exc
Strain Gage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Half bridge 300-10 kΩ
10 Vdc
±30 mV @ 10 V Exc
Strain Gage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±100 mV
Wideband Millivolt
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±10 mV
Wideband Millivolt
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±1 V
Wideband Voltage
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±40 Vdc
Wideband Voltage
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±5 V
Wideband Voltage
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±5 Vdc
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
10 Ohm @ 0°C
10 Vdc
0 to 120°C
RTD
1.0
0 to 5 Vdc
Copper 2 or 3 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 100 KHz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
10 Ohm @ 25°C
10 Vdc
0 to 120°C
RTD
1.0
0 to 5 Vdc
Copper 2 or 3 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 500 Hz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 5 KHz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±10 mV
Millivolt
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 100°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 2 or 3 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 200°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 2 or 3 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 200°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 4 Wire
5 Vdc
Not Applicable
1  In Stock
Standard
10 Vdc
-100 to 100°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 4 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 600°C
RTD
1.0
0 to 5 Vdc
Pt100 Ohm 2 or 3 Wire
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 1800°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
B
Available in 7 weeks
Standard
10 Vdc
350 to 1300°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
C
Available in 7 weeks
Standard
10 Vdc
-100 to 1350°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
K
Available in 7 weeks
Standard
10 Vdc
-100 to 760°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
J
Available in 7 weeks
Standard
10 Vdc
±10 V
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±20 Vdc
Voltage
1.0
±5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±20 Vdc
Voltage
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±40 Vdc
Voltage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±5 Vdc
Current
1.0
0 to 20 mA
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
500 to 1800°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
B
Available in 7 weeks
Standard
10 Vdc
0 to 760°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
J
Available in 7 weeks
Standard
10 Vdc
100 to 300°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
J
Available in 7 weeks
Standard
10 Vdc
0 to 500°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
K
Available in 7 weeks
Standard
10 Vdc
500 to 1750°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
R
Available in 7 weeks
Standard
10 Vdc
-100 to 400°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
T
Available in 7 weeks
Standard
10 Vdc
500 Ω
Resistance
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
4  In Stock
Standard
10 Vdc
0 to 200°C
Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
T
Available in 7 weeks
Standard
10 Vdc
1K Ω
Resistance
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±100 mV
Wideband Millivolt
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±10 mV
Wideband Millivolt
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±50 mV
Wideband Millivolt
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±10 V
Wideband Voltage
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±50 mV
Wideband Millivolt
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±10 V
Wideband Voltage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±1 V
Wideband Voltage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±20 Vdc
Wideband Voltage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±20 Vdc
Wideband Voltage
1.0
0 to 5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±40 Vdc
Wideband Voltage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
±5 V
Wideband Voltage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 1 KHz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 10 KHz
Frequency
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 20 mA
Current
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
Not Applicable
Available in 7 weeks
Standard
10 Vdc
0 to 1750°C
Non-Linearized Thermocouple
1.0
0 to 5 Vdc
Not Applicable
5 Vdc
R
Available in 7 weeks
Standard
10 Vdc
±5 V
Voltage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
8  In Stock
Full bridge 300-10 kΩ
10 Vdc
±30 mV @ 10 V Exc
Strain Gage
1.0
±5 Vdc
Not Applicable
Not Applicable
Not Applicable
thumbnail

Description The DRF series DIN rail signal conditioners are designed to accept a broad range of input signals, such as ac and dc voltage and current, frequency, tempe... Read More

DRF-TC
Price Stock Connection Type Excitation Input Ranges Input Type Isolation Number of Inputs Output Type Supply Voltage Thermocouple Type
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 300°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
E
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 700°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
J
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 1200°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
230 Vac
K
4  In Stock
Plug-in screw terminals
1 Vdc
0 to 1200°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
K
5  In Stock
Plug-in screw terminals
1 Vdc
0 to 1200°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
24 Vdc
K
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 150°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
J
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 175°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
E
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 400°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
230 Vac
J
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 150°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
230 Vac
J
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 250°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
230 Vac
J
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 250°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
230 Vac
J
2  In Stock
Plug-in screw terminals
1 Vdc
0 to 700°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
230 Vac
J
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 700°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
230 Vac
J
1  In Stock
Plug-in screw terminals
1 Vdc
0 to 150°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
K
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 250°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
K
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 700°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
230 Vac
K
2  In Stock
Plug-in screw terminals
1 Vdc
0 to 1200°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
24 Vdc
K
1  In Stock
Plug-in screw terminals
1 Vdc
850 to 1700°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
115 Vac
R
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 1600°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
S
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 1600°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
24 Vdc
S
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 1600°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
24 Vdc
S
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 200°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
24 Vdc
T
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 400°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
24 Vdc
T
Available in 7 weeks
Plug-in screw terminals
1 Vdc
0 to 300°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
0 to 10 Vdc
115 Vac
E
1  In Stock
Plug-in screw terminals
1 Vdc
0 to 800°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0
4 to 20 mA
115 Vac
E
1  In Stock
Plug-in screw terminals
1 Vdc
0 to 800°C
Thermocouple
Input to Output 3500 Veff Power to Input 3500 Veff Power to Output 3500 Veff (for AC powered models) 1K Veff (for dc powered models)
1.0