Appelez-nous au 1-888-826-6342
Thermocouple Data Loggers
![Thermocouple Data Loggers](https://assets.omega.com/images/process-control-and-monitoring-devices/data-loggers/OMYL-T15_OMYL-T16_l.jpg?imwidth=450)
Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
- Single Channel (OMYL-T15) or Dual Channel(OMYL-T16)
- User-Selectable for Type J, K, T, E, R, S, B, and N Thermocouples
- Up to 4 Million Readings (Internal Memory Size)
- Up to 4 Hz Sampling Rate
The OMYL-T15 single channel and OMYL-T16 dual channel thermocouple input data loggers are new low-cost battery powered thermocouple data loggers with integral reference junction which delivers accurate readings over a wide temperature range. These data loggers are fully user programmable for Types J, K, T, E, R, S, B and N thermocouples and are available with standard memory of 100,000 readings (OMYL-T15, OMYL-T16) or expanded memory of 4 million readings (OMYL-T15-4M, OMYL-T16-4M). These devices are programmable so that you can log data from either one or two channels.
The storage medium is non-volatile flash memory so no data is lost if the battery becomes discharged. Data logger setup as well as data retrieval is accomplished using the included standard OMYL-SOFT software. Downloaded data is stored in the OMYL-SOFT software as a text file for viewing in third party software packages or Microsoft Excel. The OMYL-SOFT standard software does not include any graphing functionality. Graphing and analyzing downloaded data files requires the OMYL-SOFT-PLUS version of the software (sold separately).
SPECIFICATIONS
Number of Inputs
OMYL-T15/OMYL-T15-4M: Single channel
OMYL-T16/OMYL-T16-4M: Dual channel
Thermocouple Connection: Female subminiature (SMP) connector
Cold Junction Compensation: Automatic
Reading Rate: 1 second to 24 hours; 2 Hz, 4 Hz in fast mode
Start Modes: Immediate start, delayed start
Memory Capacity
OMYL-T15, OMYL-T16: 100,000 readings
OMYL-T15-4M, OMYL-T16-4M: 4 million readings
Memory Wrap Around: Yes (software configurable)
Battery: 3V lithium battery [standard temperature range battery (included), optional high temperature range battery]; user replaceable
Battery Life (Standard Temperature Range Battery): 4 years at 1 minute reading rate, 230 days at 10 second reading rate, 25 days at 1 second reading rate
LED Functionality: Integrated status LED indicates data logging status, low battery or alarm condition
Alarms: Software programmable high/low thresholds
Computer Interface: USB (interface cable included)
Software: XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment: -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery
Dimensions: 45 H x 50 dia mm (1.77 x 1.97')
Weight: 70 g (2.5 oz)
Enclosure: Robust, shock-proof POM, IP65
The storage medium is non-volatile flash memory so no data is lost if the battery becomes discharged. Data logger setup as well as data retrieval is accomplished using the included standard OMYL-SOFT software. Downloaded data is stored in the OMYL-SOFT software as a text file for viewing in third party software packages or Microsoft Excel. The OMYL-SOFT standard software does not include any graphing functionality. Graphing and analyzing downloaded data files requires the OMYL-SOFT-PLUS version of the software (sold separately).
SPECIFICATIONS
Number of Inputs
OMYL-T15/OMYL-T15-4M: Single channel
OMYL-T16/OMYL-T16-4M: Dual channel
Thermocouple Connection: Female subminiature (SMP) connector
Cold Junction Compensation: Automatic
Reading Rate: 1 second to 24 hours; 2 Hz, 4 Hz in fast mode
Start Modes: Immediate start, delayed start
Memory Capacity
OMYL-T15, OMYL-T16: 100,000 readings
OMYL-T15-4M, OMYL-T16-4M: 4 million readings
Memory Wrap Around: Yes (software configurable)
Battery: 3V lithium battery [standard temperature range battery (included), optional high temperature range battery]; user replaceable
Battery Life (Standard Temperature Range Battery): 4 years at 1 minute reading rate, 230 days at 10 second reading rate, 25 days at 1 second reading rate
LED Functionality: Integrated status LED indicates data logging status, low battery or alarm condition
Alarms: Software programmable high/low thresholds
Computer Interface: USB (interface cable included)
Software: XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment: -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery
Dimensions: 45 H x 50 dia mm (1.77 x 1.97')
Weight: 70 g (2.5 oz)
Enclosure: Robust, shock-proof POM, IP65