Call us at 1-888-826-6342
OSHFV-Series High field of view IR sensor with built-in 6 digit display, 0 to 1600°C temperature range, 60:1 or 300:1 field of view and integrated dual laser sighting.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0°C (32°F) to 1300°C (2372°F)
|
60:1
|
±1% rdg or ±1.5°C
|
0°C (32°F) to 70°C (158°F)
|
Yes
|
6 digit backlit LCD display
|
0.1-1, in 0.001 increments
|
3m (10 ft)
|
0 to 5 Vdc, 4 to 20mA
|
24 Vdc
|
8 to 14 microns
|
150 ms
|
USB
|
No
|
Simultaneous analog and digital outputs
|
|
600°C (1112°F) to 1600°C (2912°F)
|
300:1
|
± 0.5% rdg + 2°C (3.5°F)
|
0°C (32°F) to 70°C (158°F)
|
Yes
|
6 digit backlit LCD display
|
0.1-1, in 0.001 increments
|
3m (10 ft)
|
0 to 5 Vdc, 4 to 20mA
|
24 Vdc
|
1 microns
|
5 ms
|
USB
|
No
|
Simultaneous analog and digital outputs
|
Compact IR sensor with adjustable emissivity, 0 to 500°C temperature range, 6 digit LCD display, 20:1 field of view and NEMA 4 IP65 housing.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0°C (32°F) to 500°C (932°F)
|
20:1
|
±1% rdg or 1.5°C (2.7°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
Yes
|
0.1-1
|
3m (10 ft)
|
0 to 5 Vdc, 4 to 20 mA, TTL
|
24 Vdc
|
8 to 14 microns
|
150 ms
|
None
|
No
|
Simultaneous analog and digital outputs
|
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Spectral Response | Response Time | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0°C (32°F) to 50°C (120°F)
|
2:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
Built-in Air Purge
|
|
0°C (32°F) to 50°C (120°F)
|
3:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type J
|
6.5 to 14 microns
|
100 ms
|
No
|
Built-in Air Purge
|
|
-18°C (0°F) to 30°C (85°F)
|
3:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
Built-in Air Purge
|
|
0°C (32°F) to 50°C (120°F)
|
3:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
Built-in Air Purge
|
|
-18°C (0°F) to 30°C (85°F)
|
3:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type T
|
6.5 to 14 microns
|
100 ms
|
No
|
Built-in Air Purge
|
Smart-Micro IR T/C Adding Smart Linearization to the Smallest IR
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0°C (32°F) to 100°C (212°F)
|
21
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.9
|
3 ft
|
0 to 10 Vdc
|
12 to 24 Vdc
|
5.5 to 20 microns
|
650 ms
|
None
|
No
|
None
|
0.9m to 9m distance range ultrasonic transducer measurement sensor with 0.5% of reading or 1.3 cm accuracy.
Product Number | Laser Output | Cable Length | Features |
---|---|---|---|
|
No
|
0.9 to 9 m (3 to 30 ft)
|
Electronic Distance Measurement Tool
|
Miniature Fixed Infrared Temperature Sensor with Optional Touch Screen Display
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-20°C (-4°F) to 1000°C (1832°F)
|
15:1
|
±1% rdg or 1°C (1.8°F)
|
0°C (32°F) to 60°C (140°F)
|
No
|
Yes
|
0.2-1
|
1 m (3 ft)
|
4 to 20 mA, 2 alarm relays output
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
None
|
No
|
Touch Screen Interface
|
|
-20°C (-4°F) to 1000°C (1832°F)
|
15:1
|
±1% rdg or 1°C (1.8°F)
|
0°C (32°F) to 60°C (140°F)
|
No
|
Yes
|
0.2-1
|
1 m (3 ft)
|
RS485 Modbus, 2 alarm relays output
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
RS485
|
No
|
Touch Screen Interface
|
|
-20°C (-4°F) to 1000°C (1832°F)
|
2:1
|
±1% rdg or 1°C (1.8°F)
|
0°C (32°F) to 60°C (140°F)
|
No
|
Yes
|
0.2-1
|
1 m (3 ft)
|
RS485 Modbus, 2 alarm relays output
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
RS485
|
No
|
Touch Screen Interface
|
|
-20°C (-4°F) to 1000°C (1832°F)
|
2:1
|
±1% rdg or 1°C (1.8°F)
|
0°C (32°F) to 60°C (140°F)
|
No
|
Yes
|
0.2-1
|
1 m (3 ft)
|
4 to 20 mA, 2 alarm relays output
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
None
|
No
|
Touch Screen Interface
|
|
-20°C (-4°F) to 1000°C (1832°F)
|
30:1
|
±1% rdg or 1°C (1.8°F)
|
0°C (32°F) to 60°C (140°F)
|
No
|
Yes
|
0.2-1
|
1 m (3 ft)
|
RS485 Modbus, 2 alarm relays output
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
RS485
|
No
|
Touch Screen Interface
|
Fixed Infrared Temperature Transmitters with a Selection of Field of Views to fit most Industrial Applications
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-20°C (-4°F) to 100°C (212°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.95
|
3 ft
|
4 to 20 mA
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
None
|
No
|
None
|
|
0°C (32°F) to 500°C (932°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.95
|
3 ft
|
4 to 20 mA
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
None
|
No
|
None
|
|
0°C (32°F) to 250°C (482°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.95
|
3 ft
|
4 to 20 mA
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
None
|
No
|
None
|
|
-20°C (-4°F) to 100°C (212°F)
|
21
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.95
|
3 ft
|
4 to 20 mA
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
None
|
No
|
None
|
|
0°C (32°F) to 250°C (482°F)
|
21
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.95
|
3 ft
|
4 to 20 mA
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
None
|
No
|
None
|
Miniature IR sensor with optional laser, -18 to 538°C temperature range, 6 output options, adjustable emissivity, 6:1 or 10:1 field of view and NEMA 4 IP65 and IP66 housing.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output (changed from Analog Output) | Supply Voltage | Spectral Response | Response Time | Intrisically Safe |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
149°C (300°F) to 538°C (1000°F)
|
61
|
±3% rdg or 5.5°C (10°F)
|
0°C (32°F) to 70°C (158°F)
|
Optional
|
No
|
0.95
|
6 ft
|
4 to 20 mA
|
12 to 24 Vdc
|
5 to 14 microns
|
150 msec, 0 to 63% of final value
|
No
|
|
-18°C (0°F) to 202°C (400°F)
|
61
|
±3% rdg or 4.4°C (8°F)
|
0°C (32°F) to 70°C (158°F)
|
Optional
|
No
|
0.95
|
6 ft
|
Thermocouple Type K
|
12 to 24 Vdc
|
5 to 14 microns
|
150 msec, 0 to 63% of final value
|
No
|
|
149°C (300°F) to 538°C (1000°F)
|
61
|
±3% rdg or 5.5°C (10°F)
|
0°C (32°F) to 70°C (158°F)
|
Optional
|
No
|
0.95
|
6 ft
|
Thermocouple Type K
|
12 to 24 Vdc
|
5 to 14 microns
|
150 msec, 0 to 63% of final value
|
No
|
|
-18°C (0°F) to 260°C (500°F)
|
101
|
±3% rdg or 4.4°C (8°F)
|
0°C (32°F) to 70°C (158°F)
|
Optional
|
No
|
0.5-1
|
6 ft
|
Thermocouple Type K
|
12 to 24 Vdc @ 50 mA
|
5.5 to 14 microns
|
150 msec, 0 to 63% of final value
|
No
|
|
-18°C (0°F) to 538°C (1000°F)
|
101
|
±3% rdg or 5.5°C (10°F)
|
0°C (32°F) to 70°C (158°F)
|
Optional
|
No
|
0.5-1
|
6 ft
|
Thermocouple Type K
|
12 to 24 Vdc @ 50 mA
|
5.5 to 14 microns
|
150 msec, 0 to 63% of final value
|
No
|
Built-in air purge IR sensor with thermocouple outputs, -18 to 250°C calibrated temperature range, 0.9 emissivity, various fields of view and NEMA 4 IP65 and IP67 housing.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Spectral Response | Response Time | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-45°C (-49°F) to 1370°C (2498°F)
|
101
|
±2% range
|
-18°C (0°F) to 85°C (185°F)
|
No
|
No
|
0.1-0.49
|
8 ft
|
Thermocouple Type K
|
2 to 20 microns
|
80 ms
|
No
|
Air Purge cooling
|
|
-18°C (0°F) to 1370°C (2498°F)
|
Close-Focus
|
±2% range
|
-18°C (0°F) to 85°C (185°F)
|
No
|
No
|
0.1-0.49
|
8 ft
|
Thermocouple Type J
|
2 to 20 microns
|
200 ms
|
No
|
Air Purge cooling
|
|
-18°C (0°F) to 1370°C (2498°F)
|
Close-Focus
|
±2% range
|
-18°C (0°F) to 85°C (185°F)
|
No
|
No
|
0.1-0.49
|
8 ft
|
Thermocouple Type K
|
2 to 20 microns
|
200 ms
|
No
|
Air Purge cooling
|
|
260°C (500°F) to 1370°C (2498°F)
|
101
|
±2% range
|
-18°C (0°F) to 85°C (185°F)
|
No
|
No
|
0.5-1
|
8 ft
|
Thermocouple Type J
|
0.1 to 5 microns
|
80 ms
|
No
|
Air Purge cooling
|
|
260°C (500°F) to 1370°C (2498°F)
|
101
|
±2% range
|
-18°C (0°F) to 85°C (185°F)
|
No
|
No
|
0.5-1
|
8 ft
|
Thermocouple Type K
|
0.1 to 5 microns
|
80 ms
|
No
|
Air Purge cooling
|
Intrinsically safe IR sensor designed for hazardous environments, -20 to 1000°C temperature range, 316 stainless steel housing, IP65 rated and adjustable emissivity.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-20°C (-4°F) to 100°C (212°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.2-1
|
16 ft
|
4 to 20 mA
|
12 to 24 Vdc
|
8 to 14 microns
|
240 ms
|
USB
|
Yes
|
IP 65 Rated , OffShore application
|
|
-20°C (-4°F) to 100°C (212°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.2-1
|
33 ft
|
4 to 20 mA
|
12 to 24 Vdc
|
8 to 14 microns
|
240 ms
|
USB
|
Yes
|
IP 65 Rated , OffShore application
|
|
0°C (32°F) to 250°C (482°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.2-1
|
16 ft
|
4 to 20 mA
|
12 to 24 Vdc
|
8 to 14 microns
|
240 ms
|
USB
|
Yes
|
IP 65 Rated , OffShore application
|
|
0°C (32°F) to 250°C (482°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.2-1
|
82 ft
|
4 to 20 mA
|
12 to 24 Vdc
|
8 to 14 microns
|
240 ms
|
USB
|
Yes
|
IP 65 Rated , OffShore application
|
|
0°C (32°F) to 1000°C (1832°F)
|
151
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.2-1
|
16 ft
|
4 to 20 mA
|
12 to 24 Vdc
|
8 to 14 microns
|
240 ms
|
USB
|
Yes
|
IP 65 Rated , OffShore application
|
Adjustable output IR sensor with adjustable emissivity, 0 to 500°C temperature range, 6 digit LCD display, 20:1 field of view and NEMA 4 IP65 housing.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0° (32°F) to 800°C (1472°F)
|
2:1
|
± 1% of the measured value or 3°C whichever value is greater
|
Display 0°C (32°F) to 70°C (158°F) Sensor Head 0°C (32°F) to 120°C (248°F)
|
No
|
Yes
|
0.1-1.2
|
3 m (10 ft)
|
0-20mA, 4-20mA, 0-10V (User Selectable), and USB 2
|
12 to 28 Vdc
|
8 to 14 microns
|
20 ms-10 sec (adjustable)
|
USB
|
No
|
Adjustable Outputs
|
|
0° (32°F) to 800°C (1472°F)
|
15:1
|
± 1% of the measured value or 3°C whichever value is greater
|
Display 0°C (32°F) to 70°C (158°F) Sensor Head 0°C (32°F) to 120°C (248°F)
|
No
|
Yes
|
0.1-1.2
|
3 m (10 ft)
|
0-20mA, 4-20mA, 0-10V (User Selectable), and USB 2
|
12 to 28 Vdc
|
8 to 14 microns
|
20 ms-10 sec (adjustable)
|
USB
|
No
|
Adjustable Outputs
|
|
0° (32°F) to 800°C (1472°F)
|
2:1
|
± 1% of the measured value or 3°C whichever value is greater
|
Display 0°C (32°F) to 70°C (158°F) Sensor Head 0°C (32°F) to 180°C (356°F)
|
No
|
Yes
|
0.1-1.2
|
3 m (10 ft)
|
0-20mA, 4-20mA, 0-10V (User Selectable), and USB 2
|
12 to 28 Vdc
|
8 to 14 microns
|
60 ms-10 sec (adjustable)
|
USB
|
No
|
Adjustable Outputs
|
|
0° (32°F) to 800°C (1472°F)
|
15:1
|
± 1% of the measured value or 3°C whichever value is greater
|
Display 0°C (32°F) to 70°C (158°F) Sensor Head 0°C (32°F) to 180°C (356°F)
|
No
|
Yes
|
0.1-1.2
|
3 m (10 ft)
|
0-20mA, 4-20mA, 0-10V (User Selectable), and USB 2
|
12 to 28 Vdc
|
8 to 14 microns
|
60 ms-10 sec (adjustable)
|
USB
|
No
|
Adjustable Outputs
|
|
0° (32°F) to 800°C (1472°F)
|
2:1
|
± 1% of the measured value or 3°C whichever value is greater
|
Display 0°C (32°F) to 70°C (158°F) Sensor Head 0°C (32°F) to 120°C (248°F)
|
No
|
Yes
|
0.1-1.2
|
3 m (10 ft)
|
0-20mA, 4-20mA, 0-10V, Thermocouple Type "K" or "J" (User selectable) and USB 2
|
12 to 28 Vdc
|
8 to 14 microns
|
20 ms-10 sec (adjustable)
|
USB
|
No
|
Adjustable Outputs
|
Stainless Steel Housing IR sensor with Thermocouple Outputs
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Spectral Response | Response Time | Intrisically Safe |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
20°C (70°F) to 90°C (190°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type J
|
6.5 to 14 microns
|
100 ms
|
No
|
|
-18°C (0°F) to 30°C (85°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type E
|
6.5 to 14 microns
|
100 ms
|
No
|
|
0°C (32°F) to 50°C (120°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type E
|
6.5 to 14 microns
|
100 ms
|
No
|
|
-18°C (0°F) to 30°C (85°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type J
|
6.5 to 14 microns
|
100 ms
|
No
|
|
0°C (32°F) to 50°C (120°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 100°C (212°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type J
|
6.5 to 14 microns
|
100 ms
|
No
|
Modbus IR transmitter with optional water cooling jacket, -40 to 2000°C temperature range, Modbus over USB, IP65 rated housing and optional laser sighting.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-40°C (-40°F) to 1000°C (1832°F)
|
30:1
|
±1% rdg
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.1-1
|
1 m (3 ft)
|
4 to 20 mA + Modbus USB
|
24 Vdc
|
8 to 14 microns
|
200 ms
|
MODBUS over USB
|
No
|
None
|
|
-40°C (-40°F) to 1000°C (1832°F)
|
Close-Focus
|
±1% rdg
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.1-1
|
1 m (3 ft)
|
4 to 20 mA + Modbus USB
|
24 Vdc
|
8 to 14 microns
|
200 ms
|
MODBUS over USB
|
No
|
None
|
|
-40°C (-40°F) to 1000°C (1832°F)
|
Close-Focus
|
±1% rdg
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.1-1
|
1 m (3 ft)
|
4 to 20 mA + Modbus USB
|
24 Vdc
|
8 to 14 microns
|
200 ms
|
MODBUS over USB
|
No
|
Air/water cooled jacket
|
High speed IR sensor with optional touch screen display, 0 to 500°C temperature range, adjustable emissivity, laser sighting and for small targets down to 1.6 mm diameter.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0°C (32°F) to 500°C (932°F)
|
Min 0.06 in spot @ 1.4 in
|
±1% rdg or 3°C (5.4°F)
|
0°C (32°F) to 50°C (122°F)
|
Yes
|
No
|
0.3-1
|
6 ft
|
4 to 20 mA,0 to 1 Vdc, 0 to 20 mA, mV/°C
|
12 to 24 Vdc
|
2-7 micron
|
10 ms
|
RS232 Modbus RTU
|
No
|
High Speed
|
|
0°C (32°F) to 500°C (932°F)
|
Min 0.12 in spot @ 2.8 in
|
±1% rdg or 3°C (5.4°F)
|
0°C (32°F) to 50°C (122°F)
|
Yes
|
No
|
0.3-1
|
6 ft
|
4 to 20 mA,0 to 1 Vdc, 0 to 20 mA, mV/°C
|
12 to 24 Vdc
|
2-7 micron
|
10 ms
|
RS232 Modbus RTU
|
No
|
High Speed
|
|
0°C (32°F) to 500°C (932°F)
|
Min 0.2 in spot @ 3.9 in
|
±1% rdg or 3°C (5.4°F)
|
0°C (32°F) to 50°C (122°F)
|
Yes
|
No
|
0.3-1
|
6 ft
|
4 to 20 mA,0 to 1 Vdc, 0 to 20 mA, mV/°C
|
12 to 24 Vdc
|
2-7 micron
|
10 ms
|
RS232 Modbus RTU
|
No
|
High Speed
|
|
0°C (32°F) to 500°C (932°F)
|
Min 0.2 in spot @ 3.9 in
|
±1% rdg or 3°C (5.4°F)
|
0°C (32°F) to 50°C (122°F)
|
Yes
|
No
|
0.3-1
|
6 ft
|
4 to 20 mA,0 to 1 Vdc, 0 to 20 mA, mV/°C
|
12 to 24 Vdc
|
2-7 micron
|
1 ms
|
RS232 Modbus RTU
|
No
|
High Speed
|
|
0°C (32°F) to 500°C (932°F)
|
Min 0.3 in spot @ 7.9 in
|
±1% rdg or 3°C (5.4°F)
|
0°C (32°F) to 50°C (122°F)
|
Yes
|
No
|
0.3-1
|
6 ft
|
4 to 20 mA,0 to 1 Vdc, 0 to 20 mA, mV/°C
|
12 to 24 Vdc
|
2-7 micron
|
1 ms
|
RS232 Modbus RTU
|
No
|
High Speed
|
Industrial Non-Contact Infrared Thermometer/Transmitter with Local Display, Dual Alarm and Analog Output
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-18°C (0°F) to 1370°C (2500°F)
|
Min 0.9 in @ Close focus
|
±1% rdg or 1.7°C or (3°F)
|
0°C (32°F) to 50°C (122°F)
|
No
|
Yes
|
0.1-1
|
15 ft
|
4 to 20 mA
|
8 to 24 Vdc
|
8 to 14 microns
|
100 ms
|
RS232
|
None
|
Min, Max, Average, Diffrential & High and low Alarm Output, NEMA Housing
|
|
-18°C (0°F) to 1370°C (2500°F)
|
Min 0.35 in @ 24 in Away
|
±1% rdg or 1.7°C or (3°F)
|
0°C (32°F) to 50°C (122°F)
|
No
|
Yes
|
0.1-1
|
15 ft
|
4 to 20 mA
|
8 to 24 Vdc
|
8 to 14 microns
|
100 ms
|
RS232
|
None
|
Min, Max, Average, Diffrential & High and low Alarm Output, NEMA Aluminum Housing
|
Subminiature IR Sensor with Thermocouple Outputs
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Spectral Response | Response Time | Intrisically Safe |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-18°C (0°F) to 30°C (85°F)
|
1:2
|
±2% range
|
-34°C (-30°F) to 85°C (185°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
|
0°C (32°F) to 50°C (120°F)
|
1:2
|
±2% range
|
-34°C (-30°F) to 85°C (185°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
|
20°C (70°F) to 90°C (190°F)
|
1:2
|
±2% range
|
-34°C (-30°F) to 85°C (185°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
|
60°C (140°F) to 105°C (220°F)
|
1:2
|
±2% range
|
-34°C (-30°F) to 85°C (185°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
|
80°C (180°F) to 120°C (250°F)
|
1:2
|
±2% range
|
-34°C (-30°F) to 85°C (185°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|
Fixed Infrared Non-Contact Temperature Sensor with adjustable emissivity and optional display
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0°C (32°F) to 250°C (482°F)
|
21
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.2-1
|
3 ft
|
4 to 20 mA
|
24 Vdc
|
8 to 14 microns
|
240 ms
|
RS485
|
No
|
None
|
Multi-channel IR Sensor with optional touch screen display, -20 to 1000°C temperature range, RS485 Modbus output, IP65 rated housing, create 6-channel system with alarms.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-20°C (-4°F) to 1000°C (1832°F)
|
20:1
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 120°C (248°F)
|
No
|
No
|
0.2-1
|
1 m (3 ft)
|
RS 485 Modbus
|
6 to 28 Vdc
|
8 to 14 microns
|
125 ms
|
Modbus
|
No
|
Optional touch-screen display
|
|
-20°C (-4°F) to 1000°C (1832°F)
|
2:1
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 120°C (248°F)
|
No
|
No
|
0.2-1
|
1 m (3 ft)
|
RS 485 Modbus
|
6 to 28 Vdc
|
8 to 14 microns
|
125 ms
|
Modbus
|
No
|
Optional touch-screen display
|
|
-20°C (-4°F) to 1000°C (1832°F)
|
8:1
|
±1% rdg or 1°C(1.8°F)
|
0°C (32°F) to 120°C (248°F)
|
No
|
No
|
0.2-1
|
1 m (3 ft)
|
RS 485 Modbus
|
6 to 28 Vdc
|
8 to 14 microns
|
125 ms
|
Modbus
|
No
|
Optional touch-screen display
|
IR sensor with RS232 output, optional display options, -18 to 538°C temperature range, 5 output options, adjustable emissivity, 6:1 field of view and NEMA 4 IP65 housing.
Product Number | Process Temperature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Supply Voltage | Spectral Response | Response Time | Communication Protocol | Intrisically Safe |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-18°C (0°F) to 538°C (1000°F)
|
6:1
|
±2% rdg or 2.2°C (4°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.1-1
|
1.8 m (6 ft)
|
Thermocouple Type K
|
12 to 24 Vdc
|
5 to 14 microns
|
100 ms
|
RS232
|
No
|
|
-18°C (0°F) to 538°C (1000°F)
|
6:1
|
±2% rdg or 2.2°C (4°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
Yes
|
0.1-1
|
1.8 m (6 ft)
|
Thermocouple Type K
|
12 to 24 Vdc
|
5 to 14 microns
|
100 ms
|
RS232
|
No
|
|
-18°C (0°F) to 538°C (1000°F)
|
6:1
|
±2% rdg or 2.2°C (4°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.1-1
|
1.8 m (6 ft)
|
4 to 20 mA
|
12 to 24 Vdc
|
5 to 14 microns
|
100 ms
|
RS232
|
No
|
|
-18°C (0°F) to 538°C (1000°F)
|
6:1
|
±2% rdg or 2.2°C (4°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.1-1
|
1.8 m (6 ft)
|
1 mV/deg
|
12 to 24 Vdc
|
5 to 14 microns
|
100 ms
|
RS232
|
No
|
|
-18°C (0°F) to 538°C (1000°F)
|
6:1
|
±2% rdg or 2.2°C (4°F)
|
0°C (32°F) to 70°C (158°F)
|
No
|
No
|
0.1-1
|
1.8 m (6 ft)
|
0 to 5 Vdc
|
12 to 24 Vdc
|
5 to 14 microns
|
100 ms
|
RS232
|
No
|
IR sensor with thermocouple outputs, -18 to 250°C calibrated temperature range, 4 output options, 0.9 emissivity, 1:1 field of view and NEMA 4 IP65 and IP67 housing.
Product Number | Process Temprature Range | Field of View | Accuracy @ Ambient | Operating Temprature range | Laser Output | Built in Display | Emissivity | Cable Length | Output | Spectral Response | Response Time | Intrisically Safe |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
-18°C (0°F) to 30°C (85°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 71°C (160°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type E
|
6.5 to 14 microns
|
100 ms
|
No
|
|
0°C (32°F) to 50°C (120°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 71°C (160°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type E
|
6.5 to 14 microns
|
100 ms
|
No
|
|
-18°C (0°F) to 30°C (85°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 71°C (160°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type J
|
6.5 to 14 microns
|
100 ms
|
No
|
|
0°C (32°F) to 50°C (120°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 71°C (160°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type J
|
6.5 to 14 microns
|
100 ms
|
No
|
|
-18°C (0°F) to 30°C (85°F)
|
1:1
|
±2% range
|
-18°C (0°F) to 71°C (160°F)
|
No
|
No
|
0.9
|
1 m (3 ft)
|
Thermocouple Type K
|
6.5 to 14 microns
|
100 ms
|
No
|