The ACI RTD Immersion sensor is a single point temperature sensor that is designed for use with electronic controllers in commercial heating and cooling building management systems.
Product Number | Category | Process Temperature Range | Sensor Application | Response Time | Accuracy | Nominal Output | Sheath Material | Probe Diameter | Sensor Threads | Probe Length | Wire Gauge | Termination Connection Type | Number Sensing Points |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-40 to 200ºC (-40 to 392ºF)
|
Immersion
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
Pt 1000
|
304 Stainless Steel
|
0.250" (6.35mm)
|
1/2" NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14" (35.6 cm) stripped leads
|
One
|
|
RTD
|
-40 to 200ºC (-40 to 392ºF)
|
Immersion
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
Pt 1000
|
304 Stainless Steel
|
0.250" (6.35mm)
|
1/2" NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14" (35.6 cm) stripped leads
|
One
|
|
RTD
|
-40 to 200ºC (-40 to 392ºF)
|
Immersion
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
Pt 100
|
304 Stainless Steel
|
0.250" (6.35mm)
|
1/2" NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14" (35.6 cm) stripped leads
|
One
|
|
RTD
|
-40 to 200ºC (-40 to 392ºF)
|
Immersion
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
Pt 100
|
304 Stainless Steel
|
0.250" (6.35mm)
|
1/2" NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14" (35.6 cm) stripped leads
|
One
|
Probes with Hastelloy Tips for use at the high pressures and temperatures found in plastic extruders. Available in single and dual element options with 1/2"-20 NF Threads.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Process Connection Size | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Ungrounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Ungrounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
6" Body Length
|
|
Thermocouple
|
J
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
|
Thermocouple
|
J
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
6" Body Length
|
|
Thermocouple
|
K
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
PVC cables with vinyl tips containing dual element thermistors, when connected to the series and shunt resistors provides a linearized output.
Product Number | Category | Sensor Type | Nominal Resistance | Probe Diameter | Sheath Housing Material | Cable Insulation | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|
|
Linear Thermistor
|
Vinyl Tip
|
6000 Ω & 30000 Ω @ 25°C
|
3.6 mm (9/64 in)
|
Vinyl
|
PVC
|
3 m (120 in)
|
Stripped Leads
|
|
Linear Thermistor
|
Vinyl-Sleeved Tip
|
6000 Ω & 30000 Ω @ 25°C
|
3.6 mm (9/64 in)
|
Vinyl
|
PVC
|
66 ft
|
Stripped Leads
|
|
Linear Thermistor
|
Vinyl-Sleeved Tip
|
6000 Ω & 30000 Ω @ 25°C
|
3.6 mm (9/64 in)
|
Vinyl
|
PVC
|
3 m (10 ft)
|
Phone Plug
|
Product Number | Category | Operating Temperature Range | Sensor Application | Response Time | Accuracy | Number Sensing Points | Set Point Tolerance | Operating Humidity Range |
---|---|---|---|---|---|---|---|---|
|
Pt1000 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
|
Pt1000 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
|
Pt100 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
|
Pt100 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
Family of linear thermistor sensors including cable, surface, air, and two immersion styles. All come with phone plug connectors.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
General Purpose Probe
|
±0.15°C
|
6000 Ω
|
Stainless Steel
|
0.125 in
|
4.50 in
|
PVC
|
120 in
|
Phone Plug
|
||
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Immersion Probe
|
±0.15°C
|
6000 Ω
|
Stainless Steel
|
0.125 in
|
4.50 in
|
PVC
|
120 in
|
Phone Plug
|
||
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Air Probe
|
±0.15°C
|
6000 Ω
|
Stainless Steel
|
0.500 in
|
1.25 in
|
PVC
|
120 in
|
Phone Plug
|
||
|
Thermistor
|
-30 to 100°C (-22 to 212°F)
|
Air Temperature
|
1/8" NPT
|
±0.15°C
|
6,000 Ω & 30,000 Ω @ 25°C
|
3
|
Plastic
|
0.125 in
|
4.5 in
|
PVC
|
120 in
|
Phone Plug
|
|
Thermistor
|
-30 to 100°C (-22 to 212°F)
|
Immersion Probe
|
1/8" NPT
|
±0.15°C
|
6,000 Ω & 30,000 Ω @ 25°C
|
3
|
304 Stainless Steel
|
0.125 in
|
4.5 in
|
PVC
|
120 in
|
Phone Plug
|
The ACI Freezer Series is designed for use with electronic controllers in commercial heating and cooling building management systems.
Product Number | Category | Process Temperature Range | Sensor Application | Response Time | Accuracy | Output | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Output Signal |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-324 to 302ºF (-198 to 150ºC)
|
Freezer Probe
|
In still air 3 min 50 sec / In water 22 (Sec)
|
Class B per IEC60751
|
Pt 1000
|
3
|
316 SS
|
0.1875” (4.76 mm)
|
2” (50.8 mm)
|
FEP/FEP (Teflon) Jacketed Cable
|
30’ (9.15 m)
|
None
|
|
RTD
|
-324 to 302ºF (-198 to 150ºC)
|
Freezer Probe
|
In still air 3 min 50 sec / In water 22 (Sec)
|
Class B per IEC60751
|
4-20mA
|
3
|
316 SS
|
0.1875” (4.76 mm)
|
2” (50.8 mm)
|
FEP/FEP (Teflon) Jacketed Cable
|
30’ (9.15 m)
|
4-20 mA (2-Wire Loop Powered)
|
The ACI Thermistor Immersion sensor is a single point temperature sensor that is designed for use with electronic controllers in commercial heating and cooling building management systems.
Product Number | Category | Process Temperature Range | Sensor Application | Response Time | Accuracy | Nominal Output | Sheath Material | Probe Diameter | Sensor Threads | Probe Length | Wire Gauge | Termination Connection Type | Number Sensing Points | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
-40 to 302ºF (-40 to 150ºC)
|
Immersion
|
10 sec (t63)
|
+/-0.36ºF (+/-0.2ºC)
|
10KΩ @77°F (25°C)
|
304 Stainless Steel
|
0.250" (6.35mm)
|
½” NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14” (35.6 cm) stripped leads
|
One
|
None
|
|
Thermistor
|
-40 to 302ºF (-40 to 150ºC)
|
Immersion
|
10 sec (t63)
|
+/-0.36ºF (+/-0.2ºC)
|
10KΩ @77°F (25°C)
|
304 Stainless Steel
|
0.250" (6.35mm)
|
½” NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14” (35.6 cm) stripped leads
|
One
|
None
|
|
Thermistor
|
-40 to 302ºF (-40 to 150ºC)
|
Immersion
|
10 sec (t63)
|
+/-0.36ºF (+/-0.2ºC)
|
20KΩ @77°F (25°C)
|
304 Stainless Steel
|
0.250" (6.35mm)
|
½” NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14” (35.6 cm) stripped leads
|
One
|
None
|
|
Thermistor
|
-40 to 302ºF (-40 to 150ºC)
|
Immersion
|
10 sec (t63)
|
+/-0.36ºF (+/-0.2ºC)
|
10KΩ @77°F (25°C)
|
304 Stainless Steel
|
0.250" (6.35mm)
|
½” NPS Male Thread
|
4" (100mm)
|
22 AWG (0.65mm)
|
14” (35.6 cm) stripped leads
|
One
|
High accuracy
|