PST joins DwyerOmega. Read more>
Configurable thermocouples with 0.010", 0.020", 0.032", or 0.040" diameter probes, metal transition joints and PFA insulated extension wires.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 800°C (32 to 1472°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Ungrounded
|
0.040 in
|
12 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Air Probe
|
Inconel® 600
|
Exposed
|
0.010 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Immersion Probe
|
Inconel® 600
|
Grounded
|
0.010 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Immersion Probe
|
Inconel® 600
|
Ungrounded
|
0.010 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Air Probe
|
Inconel® 600
|
Exposed
|
0.020 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
Wire-in-tube construction provides the simplicity of a wire thermocouple in a rigid probe package. Available in a variety of sizes and calibrations.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 230°C (32 to 450°F)
|
Immersion Probe
|
304 Stainless Steel
|
Grounded
|
0.250 in
|
2 in
|
PFA
|
20 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
|
Thermocouple
|
E
|
0 to 230°C (32 to 450°F)
|
Immersion Probe
|
304 Stainless Steel
|
Grounded
|
0.250 in
|
6 in
|
PFA
|
20 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
|
Thermocouple
|
E
|
0 to 230°C (32 to 450°F)
|
Immersion Probe
|
304 Stainless Steel
|
Grounded
|
0.125 in
|
2 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
|
Thermocouple
|
E
|
0 to 230°C (32 to 450°F)
|
Immersion Probe
|
304 Stainless Steel
|
Grounded
|
0.125 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
|
Thermocouple
|
E
|
0 to 230°C (32 to 450°F)
|
Immersion Probe
|
304 Stainless Steel
|
Ungrounded
|
0.125 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
Rugged RTD Probe with Insulated Wire and Metal Strain Relief
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Number Of Wires | Nominal Output | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Wire Gauge | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-328 to 1112°F (-200 to 600°C)
|
Immersion Probe
|
Class A per IEC60751
|
3
|
100 Ω
|
316 Stainless Steel
|
1/4" (6mm)
|
4" (100mm)
|
PFA
|
40" (1m)
|
26 AWG
|
Stripped Leads
|
None
|
|
RTD
|
-328 to 1112°F (-200 to 600°C)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
1/4" (6mm)
|
316 Stainless Steel
|
6" (152mm)
|
PFA
|
26 AWG
|
40" (1m)
|
Stripped Leads
|
None
|
|
RTD
|
Immersion Probe
|
-328 to 1112°F (-200 to 600°C)
|
Class A per IEC60751
|
100 Ω
|
3
|
316 Stainless Steel
|
1/4" (6mm)
|
8" (203mm)
|
PFA
|
26 AWG
|
40" (1m)
|
None
|
Stripped Leads
|
|
RTD
|
Immersion Probe
|
Class A per IEC60751
|
-328 to 1112°F (-200 to 600°C)
|
100 Ω
|
3
|
1/8" (3.2mm)
|
4" (100mm)
|
316 Stainless Steel
|
PFA
|
40" (1m)
|
26 AWG
|
Stripped Leads
|
None
|
|
RTD
|
-328 to 1112°F (-200 to 600°C)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
316 Stainless Steel
|
1/8" (3.2mm)
|
6" (152mm)
|
26 AWG
|
PFA
|
40" (1m)
|
Stripped Leads
|
None
|
Spring-loaded quick-connect bayonet style thermocouple probes with armored cable. Commonly used in extruder & molding equipment. Both Straight and bend options available.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Process Connection Size | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
J
|
0 to 480°C (32 to 900°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
304 Stainless Steel
|
Grounded
|
0.187 in
|
2.5 in
|
Fiberglass with Armored Cable
|
60 in
|
Standard Connector
|
90 Degree Angle Probe
|
|
Thermocouple
|
E
|
0 to 480°C (32 to 900°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
304 Stainless Steel
|
Grounded
|
0.187 in
|
3 in
|
Fiberglass with Armored Cable
|
60 in
|
Standard Connector
|
Straight Probe
|
|
Thermocouple
|
J
|
0 to 480°C (32 to 900°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
304 Stainless Steel
|
Grounded
|
0.187 in
|
2 in
|
Fiberglass with Armored Cable
|
60 in
|
Spade Lugs
|
Straight Probe
|
|
Thermocouple
|
J
|
0 to 480°C (32 to 900°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
304 Stainless Steel
|
Grounded
|
0.187 in
|
2 in
|
Fiberglass with Armored Cable
|
60 in
|
Standard Female Connector
|
Straight Probe
|
|
Thermocouple
|
J
|
0 to 480°C (32 to 900°F)
|
Immersion Probe
|
Bayonet Style Locking Fitting
|
304 Stainless Steel
|
Grounded
|
0.187 in
|
3 in
|
Fiberglass with Armored Cable
|
60 in
|
Standard Female Connector
|
Straight Probe
|
Thermocouple probes with 1/8" NPT brass compression fittings and armored cable. Commonly used in extruder & molding equipment. Both straight and bend options available.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Process Connection Size | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | Additional Feature | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 480°C (32 to 900°F)
|
Immersion Probe
|
1/8" NPT
|
304 Stainless Steel
|
Grounded
|
0.187 in
|
2 in
|
Fiberglass with Armored Cable
|
60 in
|
Standard Connector
|
Straight Probe
|
||
|
E
|
Not Applicable
|
Spade lugs
|
Not Applicable
|
Stainless Steel
|
Grounded
|
Not Applicable
|
Not Applicable
|
304 Stainless Steel
|
Not Applicable
|
Not Applicable
|
Spade Lugs
|
Flexible Probe
|
Not Applicable
|
High Temperature, Plastic Processing/Extrusion
|
|
E
|
Immersion Probe
|
Compression fitting
|
1/8 NPT
|
Stainless Steel
|
Grounded
|
Not Applicable
|
Not Applicable
|
Armoured thermocouple
|
Not Applicable
|
Not Applicable
|
Spade Lugs
|
Flexible Probe
|
Not Applicable
|
High Temperature, Plastic Processing/Extrusion
|
|
E
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Stainless Steel
|
Grounded
|
Not Applicable
|
Not Applicable
|
304 Stainless Steel
|
Not Applicable
|
Not Applicable
|
Spade Lugs
|
Flexible Probe
|
Not Applicable
|
High Temperature, Plastic Processing/Extrusion
|
|
J
|
Not Applicable
|
Spade lugs
|
Not Applicable
|
Stainless Steel
|
Grounded
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Spade Lugs
|
Flexible Probe
|
Not Applicable
|
High Temperature, Plastic Processing/Extrusion
|
Thermistor sensors great for installing into pipes or limited space applications. 1/8" or 1/4" NPT mounting threads available with 72" of Stainless Steel overbraid cable.
Product Number | Category | Process Temperature Range | Sensor Application | Process Connection Size | Accuracy | Nominal Output | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
-80 to 100°C (-22 to 212°F)
|
Immersion Probe
|
1/4" NPT
|
±0.2°C
|
2252 Ω @ 25°C
|
2
|
304 Stainless Steel
|
0.25 in
|
0.5 in
|
PFA with Stainless Steel Overbraid
|
18 in
|
Stripped Leads
|
|
|||||||||||||
|
Thermistor
|
-80 to 100°C (-22 to 212°F)
|
Immersion Probe
|
1/4" NPT
|
±0.2°C
|
2252 Ω @ 25°C
|
2
|
304 Stainless Steel
|
0.25 in
|
0.5 in
|
PFA with Stainless Steel Overbraid
|
80 in
|
Stripped Leads
|
|
Thermistor
|
-80 to 100°C (-22 to 212°F)
|
Immersion Probe
|
1/8" NPT
|
±0.2°C
|
2252 Ω @ 25°C
|
2
|
304 Stainless Steel
|
0.25 in
|
0.5 in
|
PFA with Stainless Steel Overbraid
|
80 in
|
Stripped Leads
|
|
|||||||||||||
Small diameter (0.062" or less) thermocouple probes with a compact transition joint between the probe and PFA or Fiberglass extension cable. Use where space is limited.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Air Probe
|
Inconel® 600
|
Exposed
|
0.010 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Immersion Probe
|
Inconel® 600
|
Ungrounded
|
0.010 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Air Probe
|
Inconel® 600
|
Exposed
|
0.020 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Immersion Probe
|
Inconel® 600
|
Grounded
|
0.020 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 700°C (32 to 1290°F)
|
Immersion Probe
|
Inconel® 600
|
Ungrounded
|
0.020 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
1/16",or 1.5mm diameter RTD probes available with lead wire, 3-prong connector, or handle probe. Small size provides maximum sensitivity and response time to temperature.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Probe Diameter | Sheath Housing Material | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
6 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
12 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
18 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
24 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
Stripped Leads
|
|
RTD
|
-200 to 600°C (-328 to 1112°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
0.062 in
|
304 Stainless Steel
|
6 in
|
TPE (Thermo Plastic Elastomer)
|
28 AWG
|
60 in
|
3-Prong Miniature Connector
|
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 450°C (-58 to 842°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.187 in
|
2 in
|
Fiberglass
|
26 AWG
|
40 in
|
Stripped Leads
|
None
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe
|
Class A per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel
|
0.125 in
|
2 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
None
|
Family of linear thermistor sensors including cable, surface, air, and two immersion styles. All come with phone plug connectors.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
General Purpose Probe
|
±0.15°C
|
6000 Ω
|
Stainless Steel
|
0.125 in
|
4.50 in
|
PVC
|
120 in
|
Phone Plug
|
||
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Immersion Probe
|
±0.15°C
|
6000 Ω
|
Stainless Steel
|
0.125 in
|
4.50 in
|
PVC
|
120 in
|
Phone Plug
|
||
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Air Probe
|
±0.15°C
|
6000 Ω
|
Stainless Steel
|
0.500 in
|
1.25 in
|
PVC
|
120 in
|
Phone Plug
|
||
|
Thermistor
|
-30 to 100°C (-22 to 212°F)
|
Air Temperature
|
1/8" NPT
|
±0.15°C
|
6,000 Ω & 30,000 Ω @ 25°C
|
3
|
Plastic
|
0.125 in
|
4.5 in
|
PVC
|
120 in
|
Phone Plug
|
|
Thermistor
|
-30 to 100°C (-22 to 212°F)
|
Immersion Probe
|
1/8" NPT
|
±0.15°C
|
6,000 Ω & 30,000 Ω @ 25°C
|
3
|
304 Stainless Steel
|
0.125 in
|
4.5 in
|
PVC
|
120 in
|
Phone Plug
|
Thermocouple probes with lead wire. Sheaths made with Omegaclad XL material. These probes have superior long-term stability and low drift at high temperatures.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Air Probe
|
Super OMEGACLADâ„¢ XL
|
Exposed
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Grounded
|
0.062 in
|
3 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 1038°C (32 to 1900°F)
|
Immersion Probe
|
Super OMEGACLADâ„¢ XL
|
Grounded
|
0.062 in
|
8 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 1150°C (32 to 2100°F)
|
Air Probe
|
Super OMEGACLADâ„¢ XL
|
Exposed
|
0.125 in
|
3 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
Thermocouple probes that can be cut to the desired length with a standard tube cutter to fit field applications. Plastic plug in tube end protects the wires from sharp edges.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 260°C (32 to 500°F)
|
Immersion Probe
|
304 Stainless Steel
|
Ungrounded
|
0.250 in
|
24 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
E
|
0 to 260°C (32 to 500°F)
|
Immersion Probe
|
304 Stainless Steel
|
Ungrounded
|
0.250 in
|
24 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
J
|
0 to 482°C (32 to 900°F)
|
Immersion Probe
|
304 Stainless Steel
|
Ungrounded
|
0.250 in
|
24 in
|
Fiberglass
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
J
|
0 to 540°C (32 to 1000°F)
|
Immersion Probe
|
304 Stainless Steel
|
Ungrounded
|
0.250 in
|
24 in
|
High Temprature Glass Braid
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
J
|
0 to 260°C (32 to 500°F)
|
Immersion Probe
|
304 Stainless Steel
|
Ungrounded
|
0.250 in
|
24 in
|
PFA
|
24 AWG
|
40 in
|
Stripped Leads
|
ANSI (Standard)
|
None
|
Small diameter probes that provide the most sensitive response to temperature. Type K with 310 or 316 SST sheaths and a compact transition junction.
Product Number | Category | Sensor Type | Thermocouple Type | Process Temperature Range | Sensor Application | Accuracy | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
150 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
200 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
300 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Grounded
|
0.50 mm
|
500 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
|
Thermocouple
|
Direct Contact
|
K
|
-100 to + 750°C (-148 to 1382°F)
|
Immersion Probe with Fast Response Time
|
ANSI SLE
|
310 Stainless Steel
|
Ungrounded
|
0.50 mm
|
150 mm
|
PFA
|
24 AWG
|
1 m
|
Bare wire
|
ANSI (Standard)
|
Thermocouple probe has a section of coiled 304 SS cable that allows the probe to extend and retract as needed for use in steam washdown and other applications.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Color Code Standard | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Autoclave
|
304 Stainless Steel
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Autoclave
|
304 Stainless Steel
|
Ungrounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
J
|
0 to 440°C (32 to 825°F)
|
Autoclave
|
304 Stainless Steel
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
J
|
0 to 440°C (32 to 825°F)
|
Autoclave
|
304 Stainless Steel
|
Ungrounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
None
|
|
Thermocouple
|
K
|
0 to 920°C (32 to 1690°F)
|
Autoclave
|
304 Stainless Steel
|
Grounded
|
0.062 in
|
6 in
|
PFA
|
24 AWG
|
40 in
|
Miniature Connector
|
ANSI (Standard)
|
None
|
Family of linear thermistor sensors with lead wire including cable, surface, air, and immersion probe styles. All come with resistor sets to linearize the output.
Product Number | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Immersion Probe
|
1/8" NPT
|
±0.15°C
|
6,000 Ω & 30,000 Ω @ 25°C
|
3
|
304 Stainless Steel
|
0.125 in
|
4.5 in
|
PVC
|
120 in
|
Stripped Leads
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Immersion Probe
|
±0.15°C
|
6000 Ω
|
Stainless Steel
|
0.125 in
|
4.50 in
|
PVC
|
120 in
|
Stripped Leads
|
||
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Immersion Probe - Glass
|
±0.15°C
|
6000 Ω
|
Glass
|
0.187 in
|
5.00 in
|
PVC
|
120 in
|
Stripped Leads
|
||
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Air Probe
|
1/8" NPT
|
±0.15°C
|
6,000 Ω & 30,000 Ω @ 25°C
|
3
|
304 Stainless Steel
|
0.125 in
|
4.5 in
|
PVC
|
120 in
|
Stripped Leads
|
The ACI Freezer Series is designed for use with electronic controllers in commercial heating and cooling building management systems.
Product Number | Category | Process Temperature Range | Sensor Application | Response Time | Accuracy | Output | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Output Signal |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-324 to 302ºF (-198 to 150ºC)
|
Freezer Probe
|
In still air 3 min 50 sec / In water 22 (Sec)
|
Class B per IEC60751
|
Pt 1000
|
3
|
316 SS
|
0.1875” (4.76 mm)
|
2” (50.8 mm)
|
FEP/FEP (Teflon) Jacketed Cable
|
30’ (9.15 m)
|
None
|
|
RTD
|
-324 to 302ºF (-198 to 150ºC)
|
Freezer Probe
|
In still air 3 min 50 sec / In water 22 (Sec)
|
Class B per IEC60751
|
4-20mA
|
3
|
316 SS
|
0.1875” (4.76 mm)
|
2” (50.8 mm)
|
FEP/FEP (Teflon) Jacketed Cable
|
30’ (9.15 m)
|
4-20 mA (2-Wire Loop Powered)
|
Probes with Hastelloy Tips for use at the high pressures and temperatures found in plastic extruders. Available in single and dual element options with 1/2"-20 NF Threads.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Process Connection Size | Sheath Material | Junction Type | Probe Diameter | Probe Length | Cable Insulation | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Ungrounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
|
Thermocouple
|
E
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Ungrounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
6" Body Length
|
|
Thermocouple
|
J
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
|
Thermocouple
|
J
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
6" Body Length
|
|
Thermocouple
|
K
|
0 to 510°C (32 to 950°F)
|
Immersion Probe
|
1/2-20 N.F.
|
Hastelloy C-276
|
Grounded
|
0.125 in
|
1 in
|
Fiberglass with Armored Cable
|
6 in
|
Standard Connector
|
3" Body Length
|
Product Number | Category | Operating Temperature Range | Sensor Application | Response Time | Accuracy | Number Sensing Points | Set Point Tolerance | Operating Humidity Range |
---|---|---|---|---|---|---|---|---|
|
Pt1000 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
|
Pt1000 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
|
Pt100 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
|
Pt100 RTD
|
1.5 to 50°C (35 to 122°F)
|
Wall mount
|
8 Sec (t63)
|
Class A per DIN EN 60751
|
One
|
+/- 10% of Range
|
10 to 95% RH, non-condensing
|
Class B, pt100 RTD probes have a copper tip that provides enhanced temperature response. Available in 2, 3, or 4 wire configurations and various sizes.
Product Number | Category | Process Temperature Range | Sensor Application | Accuracy | Nominal Resistance | Number Of Wires | Sheath Material | Probe Diameter | Probe Length | Cable Insulation | Wire Gauge | Cable Length | Termination Connection Type | Additional Feature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
6 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
None
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
9 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
None
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
12 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
None
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
18 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
None
|
|
RTD
|
-50 to 260°C (-58 to 500°F)
|
Immersion Probe with Fast Response Time
|
Class B per IEC60751
|
100 Ω
|
3
|
304 Stainless Steel with Copper Tip
|
0.250 in
|
24 in
|
PFA
|
26 AWG
|
40 in
|
Stripped Leads
|
None
|
Most Thermocouple Probe Styles, Handle, Molded Junction, Quick Disconnect, Heavy Duty, and Well KHSUP, KTSUP, KQSUP, TJ36CASUP, NB1-CASUP
Product Number | Thermocouple Type | Type of Sensor | Process Connection | Process Connection Size | Sheath Housing Material | Junction Type | Probe Diameter | Probe Length | Insulation | Termination Connection Type | Additional Feature 1 | Additional Feature 2 | Application of Sensor |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Exposed
|
1/4 in
|
12 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Grounded
|
1/4 in
|
12 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Grounded
|
Not Applicable
|
24 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Ungrounded
|
1/4 in
|
12 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|
|
K
|
Not Applicable
|
Direct Contact
|
Not Applicable
|
Super OMEGACLAD™ XL
|
Ungrounded
|
Not Applicable
|
18 in
|
Not Applicable
|
Ceramic Connector
|
Quick Connect
|
Not Applicable
|
Air/Gas Temperature, General Purpose, Liquid Temperature
|