100°C to 982°C temperature range cavity-type blackbody with 0.99 emissivity has a 22 mm target size and an RS-232 output.
Numéro de produit | Temperature Range | Accuracy Value | Stability | Target Size | Supply Voltage | Communication protocol | Features |
---|---|---|---|---|---|---|---|
|
100 °C (212°F) to 982°C ( 1800°F)
|
±1°C (1.8°F) ,0.25% rdg
|
±0.15°C (0.3°F)
|
0.88 in (21.56 mm)
|
120 Vac
|
RS 232
|
Portable
|
|
100 °C (212°F) to 982°C ( 1800°F)
|
±1°C (1.8°F) ,0.25% rdg
|
±0.15°C (0.3°F)
|
0.88 in (21.56 mm)
|
240 Vac
|
RS 232
|
Portable
|
Ambient +10°C to 400°C temperature range blackbody calibrator provides a fast heating time and a portable miniature design.
Numéro de produit | Temperature Range | Accuracy Value | Stability | Target Size | Supply Voltage | Communication protocol | Features |
---|---|---|---|---|---|---|---|
|
Ambient +10°C (20°F) to 400°C (752°F)
|
±1.4°C (2.5°F) ,2.5% rdg
|
±0.3°C (0.5°F)
|
1.13 in (28.57 mm)
|
115 Vac
|
None
|
Portable
|
|
Ambient +10°C (20°F) to 400°C (752°F)
|
±1.4°C (2.5°F) ,2.5% rdg
|
±0.3°C (0.5°F)
|
1.13 in (28.57 mm)
|
115 Vac
|
RS 232
|
Portable
|
|
Ambient +10°C (20°F) to 400°C (752°F)
|
±1.4°C (2.5°F) ,2.5% rdg
|
±0.3°C (0.5°F)
|
1.13 in (28.57 mm)
|
230 Vac
|
None
|
Portable
|
|
Ambient +10°C (20°F) to 400°C (752°F)
|
±1.4°C (2.5°F) ,2.5% rdg
|
±0.3°C (0.5°F)
|
1.13 in (28.57 mm)
|
230 Vac
|
RS 232
|
Portable
|
Ambient + 10°C to 215°C temperature range blackbody provides high accuracy readings to ±0.5°C and good stability to ±0.1°C
Numéro de produit | Temperature Range | Accuracy Value | Stability | Target Size | Supply Voltage | Communication protocol | Features |
---|---|---|---|---|---|---|---|
|
Ambient +10°C (20°F) to 215°C (420°F)
|
±0.5°C (0.9°F) ,0.25% rdg
|
±0.1°C (0.2°F)
|
2.50 in (63.50 mm)
|
115 Vac
|
RS 232
|
Portable
|
|
Ambient +10°C (20°F) to 215°C (420°F)
|
±0.5°C (0.9°F) ,0.25% rdg
|
±0.1°C (0.2°F)
|
2.50 in (63.50 mm)
|
230 Vac
|
RS 232
|
Portable
|
-18°C to 149°C temperature range blackbody calibrator allows high stability of ±0.05°C calibration point for hot and cold cycle
Numéro de produit | Temperature Range | Accuracy Value | Stability | Target Size | Supply Voltage | Communication protocol | Features |
---|---|---|---|---|---|---|---|
|
-18 °C (0°F) to 149°C ( 300°F)
|
±0.8°C (1.4°F)
|
±0.05°C (0.1°F)
|
2.50 in (63.50 mm)
|
115 Vac
|
RS 232
|
Portable
|
|
-18 °C (0°F) to 149°C ( 300°F)
|
±0.8°C (1.8°F)
|
±0.05°C (0.1°F)
|
2.50 in (63.50 mm)
|
230 Vac
|
RS 232
|
Portable
|
Quick Ship
66°C to 343°C temperature range blackbody calibrator has a built-in analog power controller with dial temperature readout.
Numéro de produit | Temperature Range | Accuracy Value | Stability | Target Size | Supply Voltage | Communication protocol | Features |
---|---|---|---|---|---|---|---|
|
66 °C (150°F) to 343°C ( 650°F)
|
±2% rdg
|
±3°C (5.4°F)
|
5.25 in (133 mm)
|
120 Vac
|
None
|
Portable
|
|
66 °C (150°F) to 343°C ( 650°F)
|
±2% rdg
|
±3°C (5.4°F)
|
5.25 in (133 mm)
|
240 Vac
|
None
|
Portable
|
100°C to 1046°C high temperature range cavity-type blackbody with 0.99 emissivity has a 44.5 mm diameter aperture and an RS232 output.
Numéro de produit | Temperature Range | Accuracy Value | Stability | Target Size | Supply Voltage | Communication protocol | Features |
---|---|---|---|---|---|---|---|
|
100 °C (212°F) to 1046°C ( 1915°F)
|
±1°C (1.8°F) ,0.25% rdg
|
±0.4°C (0.7°F)
|
1.75 in (44.50 mm)
|
110 Vac
|
RS 232
|
Portable
|
|
100 °C (212°F) to 1046°C ( 1915°F)
|
±1°C (1.8°F) ,0.25% rdg
|
±0.4°C (0.7°F)
|
1.75 in (44.50 mm)
|
230 Vac
|
RS 232
|
Portable
|
100°C to 398°C temperature range blackbody calibrator has a high stability to 0.1°C. The target surface presents a large 102 mm diameter.
Numéro de produit | Temperature Range | Accuracy Value | Stability | Target Size | Supply Voltage | Communication protocol | Features |
---|---|---|---|---|---|---|---|
|
100 °C (212°F) to 398°C ( 750°F)
|
±0.8°C (1.8°F)
|
±0.1°C (0.2°F)
|
4.00 in (101.60 mm)
|
115 Vac
|
RS 232
|
Portable
|
|
100 °C (212°F) to 398°C ( 750°F)
|
±0.8°C (1.8°F)
|
±0.1°C (0.2°F)
|
4.00 in (101.60 mm)
|
230 Vac
|
RS 232
|
Portable
|